Three-dimensional micro flow manifolds for miniaturized chemical analysis systems

A three-dimensional (3D) stack concept for the assembly of photolithographically fabricated microfluidic components is presented and discussed. The system uses silicon-based micropumps and simple planar structures which mimic standard elements of conventional flow systems. Detection is provided either by solid state electrochemical sensors or small volume optical detection. The general advantages of using micromachined flow manifolds for microchemical analysis are addressed. The particular benefits to be derived from this an approach compared with other assembly methods are also examined.

[1]  Albert van den Berg,et al.  A silicon integrated miniature chemical analysis system , 1992 .

[2]  Miguel Valcárcel Cases,et al.  Flow-injection analysis : principles and applications , 1987 .

[3]  Edward S. Yeung,et al.  Detectors for liquid chromatography , 1986 .

[4]  Andreas Manz,et al.  Continuous Sample Pretreatment Using a Free-Flow Electrophoresis Device Integrated onto a Silicon Chip , 1994 .

[5]  A. Manz,et al.  Miniaturized total chemical analysis systems: A novel concept for chemical sensing , 1990 .

[6]  Mary T. Gilbert,et al.  Kinetic optimization of straight open-tubular liquid chromatography , 1979 .

[7]  A. Manz,et al.  Glass chips for high-speed capillary electrophoresis separations with submicrometer plate heights , 1993 .

[8]  J. P. Riley,et al.  A modified single solution method for the determination of phosphate in natural waters , 1962 .

[9]  H Lüdi,et al.  Flow injection analysis and biosensors: applications for biotechnology and environmental control. , 1990, Journal of biotechnology.

[10]  Pierre Cambon,et al.  Potential Contamination from Glassware in the Determination of Phosphorus in Natural Waters , 1992 .

[11]  S. Terry,et al.  A gas chromatographic air analyzer fabricated on a silicon wafer , 1979, IEEE Transactions on Electron Devices.

[12]  Ernst Gassmann,et al.  On-column capillary flow cell utilizing optical waveguides for chromatographic applications , 1989 .

[13]  Jaromir Růžička,et al.  Flow injection analysis , 1981 .

[14]  S. Jacobson,et al.  High-Speed Separations on a Microchip , 1994 .

[15]  D. J. Harrison,et al.  Planar chips technology for miniaturization and integration of separation techniques into monitoring systems. Capillary electrophoresis on a chip , 1992 .

[16]  J. Danel,et al.  Quartz: a material for microdevices , 1991 .

[17]  A. Manz,et al.  A silicon flow cell for optical detection in miniaturized total chemical analysis systems , 1992 .

[18]  Andreas Manz,et al.  High-Speed Separation of Antisense Oligonucleotides on a Micromachined Capillary Electrophoresis Device , 1994 .

[19]  A. Manz,et al.  A novel approach to ion separations in solution: synchronized cyclic capillary electrophoresis (SCCE) , 1994 .

[20]  C. Urbaniczky,et al.  Integrated fluid handling system for biomolecular interaction analysis. , 1991, Analytical chemistry.

[21]  J. Michael Ramsey,et al.  Effects of injection schemes and column geometry on the performance of microchip electrophoresis devices , 1994 .

[22]  Werner Karl Schomburg,et al.  LIGA micropump for gases and liquids , 1994 .

[23]  G Tschulena Sensors for Process Control , 1988 .

[24]  Nico F. de Rooij,et al.  A Modular Miniaturized Chemical Analysis System , 1992 .

[25]  Shuichi Shoji,et al.  Prototype miniature blood gas analyser fabricated on a silicon wafer , 1988 .

[26]  B Sonnleitner,et al.  On-line determination of glucose in biotechnological processes: comparison between FIA and an in situ enzyme electrode. , 1991, Journal of biotechnology.

[27]  Piet Bergveld,et al.  An ISFET-based microlitre titrator: integration of a chemical sensor—actuator system , 1985 .

[28]  A. Manz,et al.  Synchronized Cyclic Capillary Electrophoresis - A Novel Approach to Ion Separations in Solution , 1993 .

[29]  Elo Harald Hansen,et al.  Integrated microconduits for flow injection analysis , 1984 .

[30]  A. van den Berg,et al.  Universal Approach for the Fabrication of Ca2+-, K+- and NO3- sensitive Membrane ISFETs , 1994 .

[31]  Andreas Manz,et al.  Planar Chips Technology for Miniaturization of Separation Systems: A Developing Perspective in Chemical Monitoring , 1993 .

[32]  Y. Osada,et al.  A polymer gel with electrically driven motility , 1992, Nature.

[33]  Jens Anders Branebjerg,et al.  Microfluidics-a review , 1993 .

[34]  Nico F. de Rooij,et al.  A study of a high-pressure micropump for integrated chemical analysing systems , 1992 .

[35]  H. M. Widmer,et al.  The use of chemical sensors in industry , 1990 .

[36]  K.E. Petersen,et al.  Silicon as a mechanical material , 1982, Proceedings of the IEEE.

[37]  S. Terry A gas chromatography system fabricated on a silicon wafer using integrated circuit technology , 1975 .

[38]  D. J. Harrison,et al.  Micromachining of capillary electrophoresis injectors and separators on glass chips and evaluation of flow at capillary intersections , 1994 .

[39]  Yoshihito Osada Chemical valves and gel actuators , 1991 .

[40]  Jan H. J. Fluitman,et al.  A thermo-pneumatic actuation principle for a microminiature pump and other micromechanical devices , 1989 .

[41]  A. Manz,et al.  Integrated electroosmotic pumps and flow manifolds for total chemical analysis systems , 1991, TRANSDUCERS '91: 1991 International Conference on Solid-State Sensors and Actuators. Digest of Technical Papers.

[42]  Stephen J. Haswell,et al.  Determination of total phosphate in waste waters by on-line microwave digestion incorporating colorimetric detection , 1993 .

[43]  Axel Richter,et al.  Electrohydrodynamic pumping and flow measurement , 1991, [1991] Proceedings. IEEE Micro Electro Mechanical Systems.

[44]  W. E. van der Linden,et al.  Miniaturisation in flow injection analysis Practical limitations from a theoretical point of view , 1987 .

[45]  J. Fluitman,et al.  Integrated micro-liquid dosing system , 1991, [1993] Proceedings IEEE Micro Electro Mechanical Systems.

[46]  Andreas Manz,et al.  Towards miniaturized electrophoresis and chemical analysis systems on silicon: an alternative to chemical sensors , 1993 .

[47]  M. Valcárcel,et al.  Sequential automatic on-line determination of aquiculture nutrients: phosphate and nitrate , 1992, The Journal of automatic chemistry.

[48]  J. Jorgenson,et al.  On-column sample gating for high-speed capillary zone electrophoresis. , 1991, Analytical chemistry.

[49]  D. J. Harrison,et al.  Micromachining a Miniaturized Capillary Electrophoresis-Based Chemical Analysis System on a Chip , 1993, Science.

[50]  K. Ikuta,et al.  Three dimensional micro integrated fluid systems (MIFS) fabricated by stereo lithography , 1994, Proceedings IEEE Micro Electro Mechanical Systems An Investigation of Micro Structures, Sensors, Actuators, Machines and Robotic Systems.

[51]  J. Knapp,et al.  Ceramic sensor technology for the measurement of mechanical quantities at high temperature , 1990 .

[52]  H. Lintel,et al.  A piezoelectric micropump based on micromachining of silicon , 1988 .

[53]  R. Miyake,et al.  Micro mixer with fast diffusion , 1993, [1993] Proceedings IEEE Micro Electro Mechanical Systems.

[54]  Andreas Manz,et al.  Stacked modules for micro flow systems in chemical analysis: concept and studies using an enlarged model , 1993 .

[55]  T. E. Edmonds Chemical sensing in the environment: The challenge to the analytical chemist , 1985 .

[56]  A. van den Berg,et al.  Silicon-Based Chemical Sensors and Chemical Analysis Systems , 1994 .

[57]  A. Manz,et al.  Design of an open-tubular column liquid chromatograph using silicon chip technology , 1990 .

[58]  H. Elderstig,et al.  A novel fabrication method of capillary tubes on quartz for chemical analysis applications , 1994, Proceedings IEEE Micro Electro Mechanical Systems An Investigation of Micro Structures, Sensors, Actuators, Machines and Robotic Systems.

[59]  A. Manz,et al.  Electroosmotic pumping within a chemical sensor system integrated on silicon , 1991, TRANSDUCERS '91: 1991 International Conference on Solid-State Sensors and Actuators. Digest of Technical Papers.

[60]  J. G. Smits Piezoelectric micropump with three valves working peristaltically , 1990 .

[61]  Purnendu K. Dasgupta,et al.  Flow-injection analysis in the capillary format using electroosmotic pumping , 1992 .

[62]  Purnendu K. Dasgupta,et al.  Electroosmosis: A reliable fluid propulsion system for flow injection analysis , 1994 .

[63]  Purnendu K. Dasgupta,et al.  Electroosmotically pumped capillary flow-injection analysis. Valve-based injection systems and sample throughput , 1993 .

[64]  J. Fluitman,et al.  A thermopneumatic micropump based on micro-engineering techniques , 1990 .

[65]  S. Jeanneret,et al.  Microsystems for Flow Injection Analysis , 1993 .