Head model and electrical source imaging: A study of 38 epileptic patients☆

Electrical source imaging (ESI) aims at reconstructing the electrical brain activity from scalp EEG. When applied to interictal epileptiform discharges (IEDs), this technique is of great use for identifying the irritative zone in focal epilepsies. Inaccuracies in the modeling of electro-magnetic field propagation in the head (forward model) may strongly influence ESI and lead to mislocalization of IED generators. However, a systematic study on the influence of the selected head model on the localization precision of IED in a large number of patients with known focus localization has not yet been performed. We here present such a performance evaluation of different head models in a dataset of 38 epileptic patients who have undergone high-density scalp EEG, intracranial EEG and, for the majority, subsequent surgery. We compared ESI accuracy resulting from three head models: a Locally Spherical Model with Anatomical Constraints (LSMAC), a Boundary Element Model (BEM) and a Finite Element Model (FEM). All of them were computed from the individual MRI of the patient and ESI was performed on averaged IED. We found that all head models provided very similar source locations. In patients having a positive post-operative outcome, at least 74% of the source maxima were within the resection. The median distance from the source maximum to the nearest intracranial electrode showing IED was 13.2, 15.6 and 15.6 mm for LSMAC, BEM and FEM, respectively. The study demonstrates that in clinical applications, the use of highly sophisticated and difficult to implement head models is not a crucial factor for an accurate ESI.

[1]  C. Michel,et al.  Electric source imaging of interictal activity accurately localises the seizure onset zone , 2013, Journal of Neurology, Neurosurgery & Psychiatry.

[2]  L. Geddes,et al.  The specific resistance of biological material—A compendium of data for the biomedical engineer and physiologist , 1967, Medical and biological engineering.

[3]  Marc R. Nuwer,et al.  Quantification and localization of EEG interictal spike activity in patients with surgically removed epileptogenic foci , 2012, Clinical Neurophysiology.

[4]  Thom F. Oostendorp,et al.  The conductivity of the human skull: results of in vivo and in vitro measurements , 2000, IEEE Transactions on Biomedical Engineering.

[5]  F. H. Lopes da Silva,et al.  In vivo measurement of the brain and skull resistivities using an EIT-based method and the combined analysis of SEF/SEP data , 2003, IEEE Transactions on Biomedical Engineering.

[6]  Thomas R. Knösche,et al.  Influences of skull segmentation inaccuracies on EEG source analysis , 2012, NeuroImage.

[7]  J. Ebersole,et al.  Intracranial EEG Substrates of Scalp EEG Interictal Spikes , 2005, Epilepsia.

[8]  John S. Ebersole,et al.  Localizing value of scalp EEG spikes: A simultaneous scalp and intracranial study , 2007, Clinical Neurophysiology.

[9]  D. Tucker,et al.  Scalp electrode impedance, infection risk, and EEG data quality , 2001, Clinical Neurophysiology.

[10]  H. Lüders,et al.  EEG source imaging in epilepsy—practicalities and pitfalls , 2012, Nature Reviews Neurology.

[11]  Christoph M. Michel,et al.  Spatiotemporal Analysis of Multichannel EEG: CARTOOL , 2011, Comput. Intell. Neurosci..

[12]  W. Drongelen,et al.  Estimation of in vivo human brain-to-skull conductivity ratio from simultaneous extra- and intra-cranial electrical potential recordings , 2005, Clinical Neurophysiology.

[13]  M. Fuchs,et al.  Development of Volume Conductor and Source Models to Localize Epileptic Foci , 2007, Journal of clinical neurophysiology : official publication of the American Electroencephalographic Society.

[14]  C. N. Guy,et al.  Intracerebral propagation of interictal activity in partial epilepsy: implications for source localisation. , 1994, Journal of neurology, neurosurgery, and psychiatry.

[15]  Bin He,et al.  Interictal spike analysis of high-density EEG in patients with partial epilepsy , 2011, Clinical Neurophysiology.

[16]  Gregory A. Worrell,et al.  Electrocortical source imaging of intracranial EEG data in epilepsy , 2011, 2011 Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[17]  Luigi Cattaneo,et al.  Spatiotemporal dynamics in understanding hand—object interactions , 2013, Proceedings of the National Academy of Sciences.

[18]  Christoph M. Michel,et al.  Epileptic source localization with high density EEG: how many electrodes are needed? , 2003, Clinical Neurophysiology.

[19]  Bart Vanrumste,et al.  Journal of Neuroengineering and Rehabilitation Open Access Review on Solving the Inverse Problem in Eeg Source Analysis , 2022 .

[20]  D. Lehmann,et al.  Low resolution electromagnetic tomography: a new method for localizing electrical activity in the brain. , 1994, International journal of psychophysiology : official journal of the International Organization of Psychophysiology.

[21]  Jaakko Malmivuo,et al.  Effect of measurement noise and electrode density on the spatial resolution of cortical potential distribution with different resistivity values for the skull , 2006, IEEE Transactions on Biomedical Engineering.

[22]  Robert Oostenveld,et al.  FieldTrip: Open Source Software for Advanced Analysis of MEG, EEG, and Invasive Electrophysiological Data , 2010, Comput. Intell. Neurosci..

[23]  C. Michel,et al.  Propagation of Interictal Epileptiform Activity Can Lead to Erroneous Source Localizations: A 128-Channel EEG Mapping Study , 2003, Journal of clinical neurophysiology : official publication of the American Electroencephalographic Society.

[24]  Christoph M. Michel,et al.  Localization of cortico-peripheral coherence with electroencephalography , 2011, NeuroImage.

[25]  Carlos H. Muravchik,et al.  Estimating brain conductivities and dipole source signals with EEG arrays , 2004, IEEE Transactions on Biomedical Engineering.

[26]  Jeffrey G Ojemann,et al.  Comparing Noninvasive Dense Array and Intracranial Electroencephalography for Localization of Seizures , 2010, Neurosurgery.

[27]  Christoph M. Michel,et al.  Left temporal alpha-band activity reflects single word intelligibility , 2013, Front. Syst. Neurosci..

[28]  Théodore Papadopoulo,et al.  OpenMEEG: opensource software for quasistatic bioelectromagnetics , 2010, Biomedical engineering online.

[29]  Claudio Pollo,et al.  Electroencephalographic source imaging: a prospective study of 152 operated epileptic patients , 2011, Brain : a journal of neurology.

[30]  V. Gallese,et al.  Parieto-Frontal Circuits During Observation of Hidden and Visible Motor Acts in Children. A High-density EEG Source Imaging Study , 2013, Brain Topography.

[31]  Matti Stenroos,et al.  Minimum-norm cortical source estimation in layered head models is robust against skull conductivity error☆☆☆ , 2013, NeuroImage.

[32]  S. Makeig,et al.  Effects of Forward Model Errors on EEG Source Localization , 2013, Brain Topography.

[33]  Don M. Tucker,et al.  Corrigendum: Dense Array EEG Source Estimation in Neocortical Epilepsy , 2013, Front. Neurol..

[34]  Don M. Tucker,et al.  Comparison of dense array EEG with simultaneous intracranial EEG for Interictal spike detection and localization , 2012, Epilepsy Research.

[35]  C. Michel,et al.  Electromagnetic Inverse Solutions in Anatomically Constrained Spherical Head Models , 2004, Brain Topography.

[36]  M. Cook,et al.  EEG source localization in focal epilepsy: Where are we now? , 2008, Epilepsia.

[37]  Carsten H. Wolters,et al.  Geometry-Adapted Hexahedral Meshes Improve Accuracy of Finite-Element-Method-Based EEG Source Analysis , 2007, IEEE Transactions on Biomedical Engineering.