Real time mapping QRS duration based on wavelets

The pacing for permanent pacing in bradyarrhytmias can influence ventricular activation and can contribute to marked asynchrony in extremity. In this work, we search the optimal position for right ventricular pacing according the QRS duration. We evaluate the system for detection of QRS boundaries based on wavelet transform and adaptive threshold. The system is used during pacemaker implantations in Department of Cardiology, Heart Center, Hospital Podlesi Třinec. Streszczenie. W artykule zaprezentowano system do detekcji QRS bazujący na transformacie falkowej. System sprawdzono w Klinice serca w Tryncu podczas implantacji rozrusznika serca. (Analiza w czasie rzeczywistym QRS bazująca na transformacie falkowej).

[1]  R. Orglmeister,et al.  The principles of software QRS detection , 2002, IEEE Engineering in Medicine and Biology Magazine.

[2]  F W Prinzen,et al.  Asynchronous electrical activation induces asymmetrical hypertrophy of the left ventricular wall. , 1998, Circulation.

[3]  Ingrid Daubechies,et al.  Ten Lectures on Wavelets , 1992 .

[4]  Charles K. Chui,et al.  An Introduction to Wavelets , 1992 .

[5]  Jakub Pindor,et al.  ECG width intervals detection using mathematical methods , 2009, PDeS.

[6]  S. El-Rabaie,et al.  An Efficient Technique for OFDM System Using Discrete Wavelet Transform , 2010, GPC.

[7]  G E Adomian,et al.  Myofibrillar disarray produced in normal hearts by chronic electrical pacing. , 1986, American heart journal.

[8]  Penhaker Marek,et al.  Detection of ECG Significant Waves for Biventricular Pacing Treatment , 2010, 2010 Second International Conference on Computer Engineering and Applications.

[9]  C. Li,et al.  Detection of ECG characteristic points using wavelet transforms. , 1995, IEEE transactions on bio-medical engineering.

[10]  Amara Lynn Graps,et al.  An introduction to wavelets , 1995 .

[11]  T. Nielsen,et al.  Regional myocardial blood flow in patients with sick sinus syndrome randomized to long-term single chamber atrial or dual chamber pacing--effect of pacing mode and rate. , 2000, Journal of the American College of Cardiology.

[12]  Joseph D. Bronzino,et al.  The Biomedical Engineering Handbook , 1995 .

[13]  John J. Soraghan,et al.  Detection of PD utilizing digital signal processing methods. Part 3: Open-loop noise reduction , 2001 .

[14]  Nicholas A. Peppas The Biomedical Engineering Handbook, second edition, two volumes: J.D. Bronzino, editor, CRC Press and IEEE Press, Boca Raton, FL, 2000, $189.95, 3024 pp. , 2001 .

[15]  Parul Goyal,et al.  NUC algorithm by calculating the corresponding statistics of the decomposed signal , 2010 .

[16]  C. Leclercq,et al.  Hemodynamic importance of preserving the normal sequence of ventricular activation in permanent cardiac pacing. , 1995, American heart journal.