Is Atrial Sensing of Ventricular Far‐Field Signals Important in Single‐Lead VDD Pacing?

In single‐lead VDD pacing the atrial sensitivity frequently is programmed to sensitive values. Atrial sensing of ventricular far‐field signals should be reduced by differential atrial sensing. The aim of the study was to evaluate the effectiveness of this approach. Methods: The study included 10 patients with a single‐lead VDD pacemaker (Thera 8948, Lead 5032). The atrial sensitivity was set to its most sensitive value of 0.18 mV and the telemetered intraatrial EGM was continuously recorded. After atrial tracked ventricular pacing, VVI pacing was performed with pacing rates from 100 to 160 beats/min in steps of 10 beats/min and up to 165 beats/min. The peak‐to‐peak amplitudes of P waves (P) and ventricular far‐field signals (VFFS) were measured from the recordings. The ratio P/VFFS that defines the atrial signal‐to‐noise ratio was calculated, and the time from stimulus to maximum of the far‐field signals amplitude (Tmax) was measured. Results: P measured 0.98 ± 0.76 mV. A VFFS was visible in the atrial channel in all patients with an amplitude of 0.45 ± 0.25 mV (range 0.01–1.0 mV), independent of the pacing rate. The ratio P/VFFS was 3.9 ± 4.2 (range 0.9–21.0). Tmax measured 99.4 ± 15.2 ms during sinus rhythm. A rate dependent shortening of Tmax to 92.7 ± 11.2 ms at 140 beats/min was observed (P = 0.001). At rates above 140 beats/min no further shortening occurred. Conclusion: Ventricular far‐field signals are measurable in the atrial channel of VDD systems and may reach considerable amplitudes, which are not rate dependent. Although differential sensing provides favorable P waves to ventricular far‐field signal ratios, refractory periods are needed to avoid far‐field sensing. The rate dependent shortening of the ventricular signal can be detected in the atrial channel in VDD pacing.

[1]  C. Bucknall,et al.  Is mode switching beneficial? A randomized study in patients with paroxysmal atrial tachyarrhythmias. , 1997, Journal of the American College of Cardiology.

[2]  J. Brouwer,et al.  Analysis of Atrial Sensed Far‐Field Ventricnlar Signals: A Reassessment , 1997, Pacing and clinical electrophysiology : PACE.

[3]  K. Ellenbogen,et al.  Failure of Automatic Mode Switching: Recognition and Management , 1997, Pacing and clinical electrophysiology : PACE.

[4]  C. Lau,et al.  Comparative Evaluation of Acute and Long‐Term Clinical Performance of Two Single Lead Atrial Synchronous Ventricular (VDD) Pacemakers: Diagonally Arranged Bipolar Versus Closely Spaced Bipolar Ring Electrodes , 1996, Pacing and clinical electrophysiology : PACE.

[5]  M. Marconi,et al.  VDD Single Pass Lead Pacing; Sustained Pacemaker Mediated Tachycardias Unrelated to Retrograde Atrial Activation , 1992, Pacing and clinical electrophysiology : PACE.

[6]  JAAP H. RUITER,et al.  The A‐R Interval as Exercise Indicator: A New Option for Rate Adaptation in Single and Dual Chamber Pacing , 1990, Pacing and clinical electrophysiology : PACE.

[7]  H. Schüller,et al.  Far‐Field QRS Complex Sensing Via the Atrial Pacemaker Lead. II. Prevalence, Clinical Significance and Possibility of Intraoperative Prediction in DDD Pacing. , 1988, Pacing and clinical electrophysiology : PACE.

[8]  H. Schüller,et al.  Far‐Field QRS Complex Sensing Via the Atrial Pacemaker Lead. I. Mechanism, Consequences, Differential Diagnosis and Countermeasures in AAI and VDD/DDD Pacing , 1988, Pacing and clinical electrophysiology : PACE.

[9]  J. Griffin Sensing Characteristics of the Right Atrial Appendage Electrode , 1983, Pacing and clinical electrophysiology : PACE.