Synthesis of a control model for a liquid nitrogen cooled, closed circuit, cryogenic nitrogen wind tunnel and its validation
暂无分享,去创建一个
The details of the efforts to synthesize a control-compatible multivariable model of a liquid nitrogen cooled, gaseous nitrogen operated, closed circuit, cryogenic pressure tunnel are presented. The synthesized model was transformed into a real-time cryogenic tunnel simulator, and this model is validated by comparing the model responses to the actual tunnel responses of the 0.3 m transonic cryogenic tunnel, using the quasi-steady-state and the transient responses of the model and the tunnel. The global nature of the simple, explicit, lumped multivariable model of a closed circuit cryogenic tunnel is demonstrated.
[1] E. E. Davenport,et al. The cryogenic wind tunnel concept for high Reynolds number testing , 1974 .
[2] William H. Rae,et al. Low-Speed Wind Tunnel Testing , 1966 .
[3] J. B. Adcock,et al. Specific cooling capacity of liquid nitrogen , 1977 .
[4] Robert A. Kilgore,et al. Cryogenic nitrogen as a transonic wind-tunnel test gas , 1975 .