Physical and mechanical characterisation of 3D-printed porous titanium for biomedical applications

The elastic modulus of metallic orthopaedic implants is typically 6–12 times greater than cortical bone, causing stress shielding: over time, bone atrophies through decreased mechanical strain, which can lead to fracture at the implantation site. Introducing pores into an implant will lower the modulus significantly. Three dimensional printing (3DP) is capable of producing parts with dual porosity features: micropores by process (residual pores from binder burnout) and macropores by design via a computer aided design model. Titanium was chosen due to its excellent biocompatibility, superior corrosion resistance, durability, osteointegration capability, relatively low elastic modulus, and high strength to weight ratio. The mechanical and physical properties of 3DP titanium were studied and compared to the properties of bone. The mechanical and physical properties were tailored by varying the binder (polyvinyl alcohol) content and the sintering temperature of the titanium samples. The fabricated titanium samples had a porosity of 32.2–53.4 % and a compressive modulus of 0.86–2.48 GPa, within the range of cancellous bone modulus. Other physical and mechanical properties were investigated including fracture strength, density, fracture toughness, hardness and surface roughness. The correlation between the porous 3DP titanium-bulk modulus ratio and porosity was also quantified.

[1]  A. Burstein,et al.  The Mechanical Properties of Cortical Bone , 1974 .

[2]  The effect of the particle size of an inert additive on the surface roughness of a film‐coated tablet , 1981, The Journal of pharmacy and pharmacology.

[3]  A. Perry,et al.  Young's modulus of TiN, TiC, ZrN and HfN☆ , 1987 .

[4]  Dietmar W. Hutmacher,et al.  Scaffold design and fabrication technologies for engineering tissues — state of the art and future perspectives , 2001, Journal of biomaterials science. Polymer edition.

[5]  N. Eliaz,et al.  A New Ti-5Ag Alloy for Customized Prostheses by Three-dimensional Printing (3DP™) , 2001, Journal of dental research.

[6]  K. Leong,et al.  Solid freeform fabrication of three-dimensional scaffolds for engineering replacement tissues and organs. , 2003, Biomaterials.

[7]  Naoyuki Nomura,et al.  Mechanical properties of porous titanium compacts prepared by powder sintering , 2003 .

[8]  L Catherine Brinson,et al.  Mechanics considerations for microporous titanium as an orthopedic implant material. , 2004, Journal of biomedical materials research. Part A.

[9]  Kozo Osakada,et al.  Properties of Titanium Dental Implant Models Made by Laser Processing , 2006 .

[10]  Richard J. Bibb Medical Modelling: The application of advanced design and development techniques in Medicine , 2006 .

[11]  Fanrong Pu,et al.  Effect of titanium carbide coating on the osseointegration response in vitro and in vivo. , 2007, Biomaterials.

[12]  B Vamsi Krishna,et al.  Processing and biocompatibility evaluation of laser processed porous titanium. , 2007, Acta biomaterialia.

[13]  Paul K. Hansma,et al.  Plasticity and toughness in bone , 2009 .

[14]  J. Lim,et al.  A New Approach for Manufacturing a High Porosity Ti-6Al-4V Scaffolds for Biomedical Applications , 2009 .

[15]  Cuie Wen,et al.  Biomimetic Porous Titanium Scaffolds for Orthopedic and Dental Applications , 2010 .

[16]  A. Bandyopadhyay,et al.  Influence of porosity on mechanical properties and in vivo response of Ti6Al4V implants. , 2010, Acta biomaterialia.

[17]  Wojciech Swieszkowski,et al.  Highly porous titanium scaffolds for orthopaedic applications. , 2010, Journal of biomedical materials research. Part B, Applied biomaterials.

[18]  Joydip Kundu,et al.  Biomaterial Scaffold Fabrication Techniques for Potential Tissue Engineering Applications , 2010 .

[19]  Karthikeyan Subramani,et al.  Titanium Surface Modification Techniques for Implant Fabrication – From Microscale to the Nanoscale , 2010 .

[20]  Florencia Edith Wiria,et al.  Printing of Titanium implant prototype , 2010 .

[21]  A. Palmieri,et al.  Genetic Effects of Trabecular Titanium™ on Human Osteoblast-Like Cells (MG-63): An In Vitro Study , 2010 .

[22]  Shivakumar Raman,et al.  Mechanical evaluation of porous titanium (Ti6Al4V) structures with electron beam melting (EBM). , 2010, Journal of the mechanical behavior of biomedical materials.

[23]  Saied Darwish,et al.  Fabrication of Tissue Engineering Scaffolds Using Rapid Prototyping Techniques , 2011 .

[24]  H. Shen,et al.  A numerical investigation of porous titanium as orthopedic implant material , 2011 .

[25]  S. Raman,et al.  A design for the additive manufacture of functionally graded porous structures with tailored mechanical properties for biomedical applications , 2011 .

[26]  Anupam Srivastav,et al.  An Overview of Metallic Biomaterials for Bone Support and Replacement , 2011 .

[27]  Vojislav Petrovic,et al.  Additive Manufacturing Solutions for Improved Medical Implants , 2012 .

[28]  Richard J. Bibb,et al.  Medical Modelling: The Application of Advanced Design and Rapid Prototyping Techniques in Medicine (Woodhead Publishing Series in Biomaterials) , 2014 .