Microsystems and microfluidic device for single oocyte transportation and trapping: Toward the automation of in vitro fertilising

In vitro fertilising (IVF) probably belongs to the most exciting subjects of research, not only for human assisted reproduction but also for veterinary medicine. Among the various steps of gamete manipulation, the determination of the cell to be fertilised is perhaps the most critical. Up to now, the choice of the oocyte is made using subjective criteria. It is generally the results of a visual estimation of the morphological properties of the cell. In this paper, we describe our first studies concerning the fabrication of a micro-machined lab-on-chip devoted to the analysis of the cells to be fertilised. The overall idea is to end with a system able to capture the cell on the lab-on-chip surface, to transport it to different analysis stages, and to establish an objective catalogue of the oocyte characteristics. The first issue that must be addressed is capturing, transportating and trapping a single cell at different locations on the chip surface. In this article, we present some of the silicon microsystems used for the capture and the transportation of a single oocyte. We also present a lab-on-chip concept, which exploits the microfluidic technology in order to accurately trap the cell at the desired position.

[1]  Kozo Taguchi,et al.  Levitation of a microscopic object using plural optical fibers , 2000 .

[2]  L J Kricka,et al.  Micromachined analytical devices: microchips for semen testing. , 1997, Journal of pharmaceutical and biomedical analysis.

[3]  Bernhard Wagner,et al.  Radio-frequency microtools for particle and live cell manipulation , 1994, Naturwissenschaften.

[4]  Darwin R. Reyes,et al.  Micro total analysis systems. 1. Introduction, theory, and technology. , 2002, Analytical chemistry.

[5]  S. Takayama,et al.  Rethinking gamete/embryo isolation and culture with microfluidics. , 2003, Human reproduction update.

[6]  Darwin R. Reyes,et al.  Micro total analysis systems. 2. Analytical standard operations and applications. , 2002, Analytical chemistry.

[7]  A. Berg,et al.  Micro Total Analysis Systems: Microfluidic Aspects, Integration Concept and Applications , 1997 .

[8]  David J. Beebe,et al.  Removal of Cumulus from Mammalian Zygotes using Microfluidic Techniques , 2001 .

[9]  G. Fuhr,et al.  Living cells in opto-electrical cages , 2000 .

[10]  M. Madou Fundamentals of microfabrication , 1997 .

[11]  R. Schasfoort,et al.  TUTORIAL REVIEW , 2001 .

[12]  H. Andersson,et al.  Microfluidic devices for cellomics: a review , 2003 .

[13]  Tijani Gharbi,et al.  Compensation structures for V-grooves connected to square apertures in KOH-etched (1 0 0) silicon: theory, simulation and experimentation , 2004 .

[14]  Richard A. Flynn,et al.  Optical Manipulation of Objects and Biological Cells in Microfluidic Devices , 2003 .

[15]  E. Verpoorte Microfluidic chips for clinical and forensic analysis , 2002, Electrophoresis.

[16]  D. Beebe,et al.  Microfluidic technology for assisted reproduction. , 2002, Theriogenology.