A one-dimensional analytical model for airborne contaminant transport in airliner cabins.

UNLABELLED Quick information on airborne infectious disease transmission in airliner cabins is essential to reduce the risk of infection of passengers and crew members. This investigation proposed a one-dimensional analytical model that can predict the longitudinal transmission of airborne contaminants or disease viruses inside an airliner cabin. The model considered both diffusive and convective transport of contaminants in the longitudinal direction of the cabin but assumed complete mixing of contaminants in the cabin cross-section. The effect of recirculation of the cabin air and efficiency of the high-efficiency particulate air (HEPA) filters is also considered in the model. The analytical solution for the one-dimensional contaminant transport model is obtained by using the principle of superposition and the method of separation of variables. The analytical solutions agree well with the computational fluid dynamics (CFD) results. The coupling of a CFD model with the one-dimensional analytical model could capture the impact of local airflow on contaminant transport. This analytical model has been used for analyzing contaminant transport in a 30-row all-economy-class airliner cabin with minimal computing effort. PRACTICAL IMPLICATIONS The paper presents a new one-dimensional analytical model that can provide quick information on global airborne contaminant transmissions in airliner cabins for effective response plans. The model can be used to study the effects of air exchange rates, recirculation, efficiency of the high-efficiency particulate air (HEPA) filters and longitudinal airflow on airborne contaminant transport in airliner cabins with minimal computing effort.

[1]  Q Chen,et al.  Theoretical and numerical studies of coupling multizone and CFD models for building air distribution simulations. , 2007, Indoor air.

[2]  P. Quinlisk,et al.  Update: multistate outbreak of mumps--United States, January 1-May 2, 2006. , 2006, MMWR. Morbidity and mortality weekly report.

[3]  D. Musher How contagious are common respiratory tract infections? , 2003, The New England journal of medicine.

[4]  Qingyan Chen,et al.  Influence of cabin conditions on placement and response of contaminant detection sensors in a commercial aircraft. , 2008, Journal of environmental monitoring : JEM.

[5]  Zhiqiang John Zhai,et al.  Evaluation of Various Turbulence Models in Predicting Airflow and Turbulence in Enclosed Environments by CFD: Part 2—Comparison with Experimental Data from Literature , 2007 .

[6]  K. Castro,et al.  Transmission of multidrug-resistant Mycobacterium tuberculosis during a long airplane flight. , 1996, The New England journal of medicine.

[7]  L Mora,et al.  Comparing zonal and CFD model predictions of isothermal indoor airflows to experimental data. , 2003, Indoor air.

[8]  M. Osterholm,et al.  Exposure to Mycobacterium tuberculosis during air travel , 1993, The Lancet.

[9]  L. Rosenhead Conduction of Heat in Solids , 1947, Nature.

[10]  A J Policastro,et al.  THE USE OF TECHNOLOGY IN PREPARING SUBWAY SYSTEMS FOR CHEMICAL/BIOLOGICAL TERRORISM , 1999 .

[11]  M. N. Özişik Boundary value problems of heat conduction , 1989 .

[12]  Kow-Tong Chen,et al.  Transmission of the severe acute respiratory syndrome on aircraft. , 2003, The New England journal of medicine.

[13]  John D. Spengler,et al.  Sequential box models for indoor air quality: Application to airliner cabin air quality , 1988 .

[14]  Kimberly M Thompson,et al.  Estimation of Tuberculosis Risk on a Commercial Airliner , 2004, Risk analysis : an official publication of the Society for Risk Analysis.

[15]  Farhad Memarzadeh,et al.  Methodology for Minimizing Risk from Airborne Organisms in Hospital Isolation Rooms , 2000 .

[16]  S. Orszag,et al.  Renormalization group analysis of turbulence. I. Basic theory , 1986 .

[17]  John D. Spengler,et al.  Indoor Air Quality Factors in Designing a Healthy Building , 2000 .

[18]  Chao-Hsin Lin,et al.  Optimal Sensor Placement for Airborne Contaminant Detection in an Aircraft Cabin , 2007 .

[19]  K H Dunn,et al.  Numerical simulation of airflow and airborne pathogen transport in aircraft cabins. 1. Numerical simulation of the flow field. , 2005 .

[20]  A. Mangili,et al.  Review Transmission , 2022 .

[21]  David L Powers,et al.  Boundary Value Problems and Partial Differential Equations Ed. 6 , 2009 .

[22]  Leslie M. Smith,et al.  Renormalization group analysis of turbulence , 2003 .

[23]  Tze Wai Wong,et al.  Evidence of airborne transmission of the severe acute respiratory syndrome virus. , 2004, The New England journal of medicine.

[24]  Qingyan Chen COMPARISON OF DIFFERENT k-ε MODELS FOR INDOOR AIR FLOW COMPUTATIONS , 1995 .

[25]  Zhao Zhang,et al.  Experimental and numerical investigation of airflow and contaminant transport in an airliner cabin mockup , 2009 .

[26]  Peter V. Nielsen,et al.  Application of Computer Simulated Persons in Indoor Environmental Modeling , 2002 .

[27]  Charles DeJohn,et al.  Responding to medical events during commercial airline flights. , 2002, The New England journal of medicine.