MRI-SPECT image registration using multiple MR pulse sequences to examine osteoarthritis of the knee

We have examined whether automated image registration can be used to combine metabolic information from SPECT knee scans with anatomical information from MRI. Ten patients, at risk of developing OA due to meniscal surgery, were examined. 99mTc methyldiphosphonate SPECT, T2-weighted fast spin echo (FSE) MRI, and T1-weighted, 3D fat-suppressed gradient recalled echo (SPGR) MRI images were obtained. Registration was performed using normalized mutual information. For each patient, FSE data was registered to SPGR data, providing a composite MRI image with each voxel represented by two intensities (ISPGR, IFSE). Modifications to the registration algorithm were made to allow registration of SPECT data (one intensity per voxel) to composite MRI data (2 intensities per voxel). Registration sources was assessed by visual inspection of uptake localization over expected anatomical locations, and the absence of uptake over unlikely sites. Three patients were discarded from SPECT-MRI registration tests since they had metallic artifacts that prevented co-registration of MR data. Registration of SPECT to SPGR or FSE data alone proved unreliable, with less than 50% of attempts succeeding. The modified algorithm, treating co-registered SPGR and FSE data as a two-value-per-voxel image, proved most reliable, allowing registration of all patients with no metallic artifacts on MRI.

[1]  M. Feinsod,et al.  Quantitative bone scintigraphy using SPECT. , 1989, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[2]  T D Cooke,et al.  Radiographic assessment of progression in osteoarthritis. , 1987, Arthritis and rheumatism.

[3]  P Young,et al.  Prediction of the progression of joint space narrowing in osteoarthritis of the knee by bone scintigraphy. , 1993, Annals of the rheumatic diseases.

[4]  I. Murray,et al.  SPECT for acute knee pain. , 1990, Clinical nuclear medicine.

[5]  Paul A. Viola,et al.  Multi-modal volume registration by maximization of mutual information , 1996, Medical Image Anal..

[6]  R. P. Johnson,et al.  Chronic knee pain assessed by SPECT: comparison with other modalities. , 1985, Radiology.

[7]  C. Pelizzari,et al.  Clinical validation of SPECT and CT/MRI image registration in radiolabeled monoclonal antibody studies of colorectal carcinoma. , 1994, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[8]  Colin Studholme,et al.  An overlap invariant entropy measure of 3D medical image alignment , 1999, Pattern Recognit..

[9]  Max A. Viergever,et al.  A survey of medical image registration , 1998, Medical Image Anal..

[10]  Colin Studholme,et al.  Measures of 3D medical image alignment , 1997 .

[11]  J. Mazziotta,et al.  MRI‐PET Registration with Automated Algorithm , 1993, Journal of computer assisted tomography.

[12]  B. Munch,et al.  3-D repositioning and differential images of volumetric CT measurements. , 1993, IEEE transactions on medical imaging.

[13]  Colin Studholme,et al.  Automated 3-D registration of MR and CT images of the head , 1996, Medical Image Anal..

[14]  I. Fogelman,et al.  The bone scan: where are we now? , 1995, Seminars in nuclear medicine.

[15]  Colin Studholme,et al.  Voxel similarity measures for automated image registration , 1994, Other Conferences.

[16]  I. Fogelman,et al.  SPECT bone scintigraphy of anterior cruciate ligament injury. , 1996, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[17]  C. E. Henning,et al.  Knee joint surface changes. Long-term follow-up meniscus tear treatment in stable anterior cruciate ligament reconstructions. , 1983, Clinical orthopaedics and related research.

[18]  J. Mazziotta,et al.  Rapid Automated Algorithm for Aligning and Reslicing PET Images , 1992, Journal of computer assisted tomography.

[19]  P. C. Jackson,et al.  99mTc HMDP bone scanning in generalised nodal osteoarthritis. II. The four hour bone scan image predicts radiographic change. , 1986, Annals of the rheumatic diseases.

[20]  P F Hemler,et al.  A versatile system for multimodality image fusion. , 1995, Journal of image guided surgery.