X-CSIT: a toolkit for simulating 2D pixel detectors

A new, modular toolkit for creating simulations of 2D X-ray pixel detectors, X-CSIT (X-ray Camera SImulation Toolkit), is being developed. The toolkit uses three sequential simulations of detector processes which model photon interactions, electron charge cloud spreading with a high charge density plasma model and common electronic components used in detector readout. In addition, because of the wide variety in pixel detector design, X-CSIT has been designed as a modular platform so that existing functions can be modified or additional functionality added if the specific design of a detector demands it. X-CSIT will be used to create simulations of the detectors at the European XFEL, including three bespoke 2D detectors: the Adaptive Gain Integrating Pixel Detector (AGIPD), Large Pixel Detector (LPD) and DePFET Sensor with Signal Compression (DSSC). These simulations will be used by the detector group at the European XFEL for detector characterisation and calibration. For this purpose, X-CSIT has been integrated into the European XFEL's software framework, Karabo. This will further make it available to users to aid with the planning of experiments and analysis of data. In addition, X-CSIT will be released as a standalone, open source version for other users, collaborations and groups intending to create simulations of their own detectors.

[1]  Markus Kuster,et al.  Detector Development for the European XFEL: Requirements and Status , 2012, 1210.1750.

[2]  Gianluca Geloni,et al.  The European X-ray Free-Electron Laser , 2015 .

[3]  C. Angelsen,et al.  Development of the LPD, a high dynamic range pixel detector for the European XFEL , 2012, 2012 IEEE Nuclear Science Symposium and Medical Imaging Conference Record (NSS/MIC).

[4]  Heinz Graafsma,et al.  Requirements for and development of 2 dimensional X-ray detectors for the European X-ray Free Electron Laser in Hamburg , 2009 .

[5]  Matej Batic,et al.  Photon Elastic Scattering Simulation: Validation and Improvements to Geant4 , 2012, IEEE Transactions on Nuclear Science.

[6]  Steffen Hauf,et al.  Karabo: An Integrated Software Framework Combining Control, Data Management, and Scientific Computing Tasks , 2013 .

[7]  Robert Klanner,et al.  Impact of plasma effects on the performance of silicon sensors at an X-ray FEL , 2010 .

[8]  Matteo Porro,et al.  DEPFET sensor with intrinsic signal compression developed for use at the XFEL free electron laser radiation source , 2010 .

[9]  Giuseppe A. P. Cirrone,et al.  Validation of the Geant4 electromagnetic photon cross-sections for elements and compounds , 2010 .

[10]  J. Joseph,et al.  Development of a compact fast CCD camera and resonant soft x-ray scattering endstation for time-resolved pump-probe experiments. , 2011, The Review of scientific instruments.

[11]  Norbert Meidinger,et al.  pnCCD for photon detection from near-infrared to X-rays , 2006 .

[12]  H. Graafsma,et al.  2 0 0 9 J I N S T 4 P 0 9 0 1 0 , 2009 .

[13]  Georg Weidenspointner,et al.  MEGAlib: simulation and data analysis for low-to-medium-energy gamma-ray telescopes , 2008, Astronomical Telescopes + Instrumentation.

[14]  C. Greenough,et al.  Computational modelling of semiconducting X-ray detectors , 2002 .

[15]  Georg Weidenspointner,et al.  Development of the DEPFET Sensor With Signal Compression: A Large Format X-Ray Imager With Mega-Frame Readout Capability for the European XFEL , 2011, IEEE Transactions on Nuclear Science.

[16]  Th. Tschentscher,et al.  Technical Report: The European X-ray Free-Electron Laser Facility: A New Infrastructure for Research Using Ultrashort, Coherent X-ray Pulses of Extreme Brightness , 2006 .

[17]  Matteo Porro Development of the DEPFET Sensor With Signal Compression: A Large Format X-Ray Imager With Mega-Frame Readout Capability for the European XFEL , 2011, IEEE Transactions on Nuclear Science.

[18]  S. Incerti,et al.  Geant4 developments and applications , 2006, IEEE Transactions on Nuclear Science.

[19]  Steffen Hauf,et al.  Performance of an LPD prototype detector at MHz frame rates under Synchrotron and FEL radiation , 2013 .

[20]  H. Brauninger,et al.  The x-ray telescope of CAST , 2007 .

[21]  E. A. Schneidmiller,et al.  Photon beam properties at the European XFEL , 2011 .

[22]  A. H. Walenta,et al.  Large-format, high-speed, X-ray pnCCDs combined with electron and ion imaging spectrometers in a multipurpose chamber for experiments at 4th generation light sources , 2010 .

[23]  H. Graafsma,et al.  Performance simulation of a detector for 4th generation photon sources: The AGIPD , 2009 .