Evaluation of sample hemolysis in blood collected by S-Monovette® using vacuum or aspiration mode

Background: In vitro hemolysis can be induced by several biological and technical sources, and may be worsened by forced aspiration of blood in vacuum tubes. This study was aimed to compare the probability of hemolysis by drawing blood with a commercial evacuated blood collection tube, and S-Monovette used either in the “vacuum” or “aspiration” mode. Materials and methods: The study population consisted in 20 healthy volunteers. A sample was drawn into 4.0 mL BD Vacutainer serum tube from a vein of one upper arm. Two other samples were drawn with a second venipuncture from a vein of the opposite arm, into 4.0 mL S-Monovette serum tubes, by both vacuum an aspiration modes. After separation, serum potassium, lactate dehydrogenase (LD) and hemolysis index (HI) were tested on Beckman Coulter DxC. Results: In no case the HI exceed the limit of significant hemolysis. As compared with BD Vacutainer, no significant differences were observed for potassium and LD using S-Monovette with vacuum method. Significant increased values of both parameters were however found in serum collected into BD Vacutainer and S-Monovette by vacuum mode, compared to serum drawn by S-Monovette in aspiration mode. The mean potassium bias was 2.2% versus BD Vacutainer and 2.4% versus S-Monovette in vacuum mode, that of LD was 2.7% versus BD Vacutainer and 2.1% versus S-Monovette in vacuum mode. None of these variations exceeded the allowable total error. Conclusions: Although no significant macro-hemolysis was observed with any collection system, the less chance of producing micro-hemolysis by S-Monovette in aspiration mode suggest that this device may be used when a difficult venipuncture combined with the vacuum may increase the probability of spurious hemolysis.

[1]  Mario Plebani,et al.  Continuous-Flow Automation and Hemolysis Index , 2013, Journal of laboratory automation.

[2]  G. Lippi,et al.  An Unusual Case of a Primary Blood Collection Tube with Floating Separator Gel , 2012, Journal of clinical laboratory analysis.

[3]  G. Lippi,et al.  Quality Standards for Sample Collection in Coagulation Testing , 2012, Seminars in Thrombosis & Hemostasis.

[4]  G. Lippi,et al.  Preanalytical management: serum vacuum tubes validation for routine clinical chemistry , 2012, Biochemia medica.

[5]  A. Šimundić,et al.  Special issue: Responsible writing in science , 2012 .

[6]  A. Dirican,et al.  Stability studies of common biochemical analytes in serum separator tubes with or without gel barrier subjected to various storage conditions , 2012, Biochemia medica.

[7]  G. Lippi,et al.  Primary blood tubes mixing: time for updated recommendations , 2012, Clinical chemistry and laboratory medicine.

[8]  G. Lippi,et al.  Incomplete filling of lithium heparin tubes affects the activity of creatine kinase and γ-glutamyltransferase , 2012, British journal of biomedical science.

[9]  G. Lippi,et al.  Studies on in vitro hemolysis and utility of corrective formulas for reporting results on hemolyzed specimens. , 2011, Biochemia medica.

[10]  A. Šimundić,et al.  Preanalytical quality improvement: from dream to reality , 2011, Clinical chemistry and laboratory medicine.

[11]  Mario Plebani,et al.  Hemolyzed specimens: a major challenge for emergency departments and clinical laboratories , 2011, Critical reviews in clinical laboratory sciences.

[12]  A. Šimundić,et al.  Overview on patient safety in healthcare and laboratory diagnostics , 2010 .

[13]  A. Šimundić,et al.  Hemolysis detection and management of hemolyzed specimens , 2010 .

[14]  M. Halm,et al.  Obtaining blood samples from peripheral intravenous catheters: best practice? , 2009, American journal of critical care : an official publication, American Association of Critical-Care Nurses.

[15]  Mario Plebani,et al.  Multicenter evaluation of the hemolysis index in automated clinical chemistry systems , 2009, Clinical chemistry and laboratory medicine.

[16]  Mario Plebani,et al.  Haemolysis: an overview of the leading cause of unsuitable specimens in clinical laboratories , 2008, Clinical chemistry and laboratory medicine.

[17]  Kiyoshi Ichihara,et al.  Insufficient filling of vacuum tubes as a cause of microhemolysis and elevated serum lactate dehydrogenase levels. Use of a data-mining technique in evaluation of questionable laboratory test results , 2006, Clinical chemistry and laboratory medicine.

[18]  G. Lippi,et al.  Preanalytical variability: the dark side of the moon in laboratory testing , 2006, Clinical chemistry and laboratory medicine.

[19]  G. Lippi,et al.  Preanalytical variability in laboratory testing: influence of the blood drawing technique , 2005, Clinical chemistry and laboratory medicine.

[20]  C Ricós,et al.  Current databases on biological variation: pros, cons and progress. , 1999, Scandinavian journal of clinical and laboratory investigation.

[21]  G. J. Wilcox,et al.  Does transfusion using a syringe infusion pump and small‐gauge needle cause hemolysis? , 1981, Transfusion.