UNLABELLED
The main justification for ventilation has historically been to create a healthy indoor environment. Ventilation removes air pollutants originating inside the building, including bio-effluents. The outdoor air supply rate that has been found by experience to provide subjectively acceptable indoor air quality and to prevent the accumulation of moisture in the building is generally sufficient to maintain the concentration of pollutants at healthily low levels. Until 5 years ago this would have been the justification for current ventilation practices, but in 1999 the first of a series of experiments was published, revealing new mechanisms by which raised levels of indoor air pollution may reduce productivity, either in addition to or instead of having negative effects on comfort and health. It was shown in realistic experimental exposures lasting up to 5 h that the performance of simulated office work could be significantly increased by removing common indoor sources of air pollution, such as floor-coverings, used supply air filters and personal computers, or by keeping them in place and increasing the rate at which clean outdoor air was supplied from 3 to 10 to 30 l s(-1) per person. These short-term effects were demonstrated repeatedly even at pollutant levels that had no measurable effects on the perception of air quality by the occupants themselves, although there were effects on subclinical SBS symptoms such as headache. Temperature and noise distraction have since been studied in directly comparable exposures. The prediction arising from these experiments, that the performance of real office work over time would be significantly and substantially affected by the changes in indoor environmental quality that take place in the course of normal building operation, have recently been validated in 8-week field intervention experiments carried out in call-centers in northern Europe and the Tropics. These findings have far-reaching implications for the efficient use of energy in buildings.
PRACTICAL IMPLICATIONS
It has now been shown beyond reasonable doubt that poor indoor air quality in buildings can decrease productivity in addition to causing visitors to express dissatisfaction. The size of the effect on most aspects of office work performance appears to be as high as 6-9%, the higher value being obtained in field validation studies. It is usually more energy-efficient to eliminate sources of pollution than to increase outdoor air supply rates. The experiments summarized in this article have documented and quantified relationships that can be used in making cost-benefit analyses of either solution for a given building. The high cost of labor per unit floor area ensures that payback times will usually be as low as 2 years.
[1]
Povl Ole Fanger,et al.
Limiting criteria for human exposure to low humidity indoors
,
2002
.
[2]
K. W. Tham,et al.
Call-centre operator performance with new and used filters at two outdoor air supply rates
,
2003
.
[3]
Pawel Wargocki,et al.
PRODUCTIVITY IS AFFECTED BY THE AIR QUALITY IN OFFICES
,
2000
.
[4]
P. Fanger,et al.
Human response to personalized ventilation and mixing ventilation.
,
2004,
Indoor air.
[5]
A. Stuart,et al.
Non-Parametric Statistics for the Behavioral Sciences.
,
1957
.
[6]
D K Milton,et al.
Risk of sick leave associated with outdoor air supply rate, humidification, and occupant complaints.
,
2000,
Indoor air.
[7]
Povl Ole Fanger,et al.
Pollution source control and ventilation improve health, comfort and productivity
,
2000
.
[8]
Povl Ole Fanger,et al.
Sensory emission rates from personal computers and television sets
,
2003
.
[9]
D. Wyon.
Enhancing productivity while reducing energy use in buildings
,
2000
.
[10]
G. Clausen,et al.
The effects of moderate heat stress and open-plan office noise distraction on SBS symptoms and on the performance of office work.
,
2004,
Indoor air.
[11]
P Wargocki,et al.
Subjective perceptions, symptom intensity and performance: a comparison of two independent studies, both changing similarly the pollution load in an office.
,
2002,
Indoor air.
[12]
P. Fanger,et al.
The effects of outdoor air supply rate in an office on perceived air quality, sick building syndrome (SBS) symptoms and productivity.
,
2000,
Indoor air.
[13]
Povl Ole Fanger,et al.
Call-centre occupant response to new and used filters at two outdoor air supply rates
,
2002
.
[14]
P Wargocki,et al.
Effects of pollution from personal computers on perceived air quality, SBS symptoms and productivity in offices.
,
2004,
Indoor air.
[15]
Povl Ole Fanger,et al.
Perceived air quality, SBS-symptoms and productivity in an office at two pollution loads
,
1999
.
[16]
Pawel Wargocki,et al.
The performance and subjective responses of call-center operators with new and used supply air filters at two outdoor air supply rates.
,
2004,
Indoor air.
[17]
P Wargocki,et al.
Perceived air quality, sick building syndrome (SBS) symptoms and productivity in an office with two different pollution loads.
,
1999,
Indoor air.