The Conventional Non-Articulated SACH or a Multiaxial Prosthetic Foot for Hypomobile Transtibial Amputees? A Clinical Comparison on Mobility, Balance, and Quality of Life

The effects of a non-articulated SACH and a multiaxial foot-ankle mechanism on the performance of low-activity users are of great interest for practitioners in amputee rehabilitation. The aim of this study is to compare these two prosthetic feet and assess possible improvements introduced by the increased degrees of freedom provided by the multiaxial foot. For this purpose, a group of 20 hypomobile transtibial amputees (TTAs) had their usual SACH replaced with a multiaxial foot. Participants' functional mobility, involving ambulatory skills in overground level walking, ramps, and stairs, was evaluated by performing Six-Minute Walking Test (6MWT), Locomotor Capability Index-5 (LCI-5), Hill Assessment Index (HAI), and Stair Assessment Index (SAI). Balance performances were assessed using Berg Balance Scale (BBS) and analysing upper body accelerations during gait. Moreover, the Prosthesis Evaluation Questionnaire (PEQ) was performed to indicate the prosthesis-related quality of life. Results showed that participants walked faster using the multiaxial foot (p < 0.05) maintaining the same upright gait stability. Significant improvements with the multiaxial foot were also observed in BBS, LCI-5, and SAI times and 4 of 9 subscales of the PEQ. Our findings demonstrate that a multiaxial foot represents a considerable alternative solution with respect to the conventional SACH in the prosthetic prescription for hypomobile TTAs.

[1]  G. Beebe,et al.  The “Geriatric” Amputee , 1972, Annals of surgery.

[2]  Marco Iosa,et al.  Assessment of gait stability, harmony, and symmetry in subjects with lower-limb amputation evaluated by trunk accelerations. , 2014, Journal of rehabilitation research and development.

[3]  H J Yack,et al.  Physiological measurements of walking and running in people with transtibial amputations with 3 different prostheses. , 1999, The Journal of orthopaedic and sports physical therapy.

[4]  J. Cheng,et al.  Significance of non-level walking on transtibial prosthesis fitting with particular reference to the effects of anterior-posterior alignment. , 2001, Journal of rehabilitation research and development.

[5]  Francesco Paradisi,et al.  A comparison between the suction suspension system and the hypobaric Iceross Seal-In® X5 in transtibial amputees , 2013, Prosthetics and orthotics international.

[6]  Karl Swedberg,et al.  Six minute walk test. , 2005, European heart journal.

[7]  W. Miller,et al.  The influence of falling, fear of falling, and balance confidence on prosthetic mobility and social activity among individuals with a lower extremity amputation. , 2001, Archives of physical medicine and rehabilitation.

[8]  Nicolas Vuillerme,et al.  Biomechanics and physiological parameters during gait in lower-limb amputees: a systematic review. , 2011, Gait & posture.

[9]  Pamela Gallagher,et al.  Understanding the benefits of prosthetic prescription: exploring the experiences of practitioners and lower limb prosthetic users , 2011, Disability and rehabilitation.

[10]  J Perry,et al.  Below-knee amputee gait in stair ambulation. A comparison of stride characteristics using five different prosthetic feet. , 1994, Clinical orthopaedics and related research.

[11]  Xavier Bonnet,et al.  Evaluation of a new geriatric foot versus the Solid Ankle Cushion Heel foot for low-activity amputees , 2015, Prosthetics and orthotics international.

[12]  Israel Dudkiewicz,et al.  Satisfaction rates amongst elderly amputees provided with a static prosthetic foot , 2011, Disability and rehabilitation.

[13]  George N S Marinakis,et al.  Interlimb symmetry of traumatic unilateral transtibial amputees wearing two different prosthetic feet in the early rehabilitation stage. , 2004, Journal of rehabilitation research and development.

[14]  Stefania Fatone,et al.  Validity and reliability of the Berg Balance Scale for community-dwelling persons with lower-limb amputation. , 2013, Archives of physical medicine and rehabilitation.

[15]  Vimonwan Hiengkaew,et al.  Minimal detectable changes of the Berg Balance Scale, Fugl-Meyer Assessment Scale, Timed "Up & Go" Test, gait speeds, and 2-minute walk test in individuals with chronic stroke with different degrees of ankle plantarflexor tone. , 2012, Archives of physical medicine and rehabilitation.

[16]  K. Turcot,et al.  Comparison of the International Committee of the Red Cross foot with the solid ankle cushion heel foot during gait: a randomized double-blind study. , 2013, Archives of physical medicine and rehabilitation.

[17]  Janice J Eng,et al.  A comparison of two prosthetic feet on the multi-joint and multi-plane kinetic gait compensations in individuals with a unilateral trans-tibial amputation. , 2004, Clinical biomechanics.

[18]  L. Mollinger,et al.  Age- and gender-related test performance in community-dwelling elderly people: Six-Minute Walk Test, Berg Balance Scale, Timed Up & Go Test, and gait speeds. , 2002, Physical therapy.

[19]  K. Andrews,et al.  Rehabilitation in limb deficiency. 3. The geriatric amputee. , 1996, Archives of physical medicine and rehabilitation.

[20]  ATS statement: guidelines for the six-minute walk test. , 2002, American journal of respiratory and critical care medicine.

[21]  R. Neptune,et al.  The effect of foot and ankle prosthetic components on braking and propulsive impulses during transtibial amputee gait. , 2006, Archives of physical medicine and rehabilitation.

[22]  Marco Iosa,et al.  Ability and Stability of Running and Walking in Children with Cerebral Palsy , 2013, Neuropediatrics.

[23]  G D Reiber,et al.  Prosthesis evaluation questionnaire for persons with lower limb amputations: assessing prosthesis-related quality of life. , 1998, Archives of physical medicine and rehabilitation.

[24]  A L Hof,et al.  Comparison of gait using a Multiflex foot versus a Quantum foot in knee disarticulation amputees , 1993, Prosthetics and orthotics international.

[25]  J. Perry,et al.  The effect of five prosthetic feet on the gait and loading of the sound limb in dysvascular below-knee amputees. , 1995, Journal of rehabilitation research and development.

[26]  M. Iosa,et al.  Assessment of the effects of carbon fiber and bionic foot during overground and treadmill walking in transtibial amputees. , 2013, Gait & posture.

[27]  S. Lin,et al.  Six-minute walk test in persons with transtibial amputation. , 2008, Archives of physical medicine and rehabilitation.

[28]  Katheryn J Allyn,et al.  Evaluation of function, performance, and preference as transfemoral amputees transition from mechanical to microprocessor control of the prosthetic knee. , 2007, Archives of physical medicine and rehabilitation.

[29]  Jason T. Kahle,et al.  Ramp descent performance with the C-Leg and interrater reliability of the Hill Assessment Index , 2013, Prosthetics and orthotics international.

[30]  Giovanni Morone,et al.  Assessment of upper-body dynamic stability during walking in patients with subacute stroke. , 2012, Journal of rehabilitation research and development.

[31]  Vibhor Agrawal,et al.  Application of self-report and performance-based outcome measures to determine functional differences between four categories of prosthetic feet. , 2012, Journal of rehabilitation research and development.

[32]  L. Resnik,et al.  Reliability of Outcome Measures for People With Lower-Limb Amputations: Distinguishing True Change From Statistical Error , 2011, Physical Therapy.

[33]  W. A. Hubbard,et al.  Establishment of consistent gait after fitting of new components. , 1995, Journal of rehabilitation research and development.

[34]  Franco Franchignoni,et al.  Reliability, validity, and responsiveness of the locomotor capabilities index in adults with lower-limb amputation undergoing prosthetic training. , 2004, Archives of physical medicine and rehabilitation.

[35]  A Cappozzo,et al.  Low frequency self-generated vibration during ambulation in normal men. , 1982, Journal of biomechanics.

[36]  S. E. Solomonidis,et al.  Biomechanical evaluation of SACH and uniaxial feet , 1984, Prosthetics and orthotics international.

[37]  D. Shurr,et al.  Comparison of Energy Cost and Gait Efficiency During Ambulation in Below-Knee Amputees Using Different Prosthetic Feet—A Preliminary Report , 1988 .

[38]  S. Wood-Dauphinée,et al.  The Balance Scale: reliability assessment with elderly residents and patients with an acute stroke. , 1995, Scandinavian journal of rehabilitation medicine.