A novel application of frequency response analysis for wireless power transfer system

A method of frequency response analysis (FRA) is broadly used to observe a deformation of power transformers. The transmitting and receiving windings in magnetically coupled wireless power transfer (WPT) system can be considered as an air core transformer. This paper presents a new application of FRA with the circuit analysis, finite element method (FEM) simulations and the practical analyses on the prototype of two-winding WPT system that operates at the resonance frequency of 1.16 MHz. The FRA results contribute to a verification of the power transfer coefficient over the distance and to an enhancement of the transfer efficiency of WPT system. In addition, the critical distance occurring the maximum power transfer and the decline of the efficiency due to the frequency bifurcation at the near gap between the windings can be analyzed.

[1]  Ahmed Abu-Siada,et al.  State-of-the-art literature review of WPT: Current limitations and solutions on IPT , 2018 .

[2]  N. Tesla,et al.  High frequency oscillators for electro-therapeutic and other purposes , 2015, Proceedings of the IEEE.

[3]  Hua Zhang,et al.  An Inductive and Capacitive Combined Wireless Power Transfer System With LC-Compensated Topology , 2016, IEEE Transactions on Power Electronics.

[4]  Ryszard Malewski,et al.  Impulse testing of power transformers using the transfer function method , 1988 .

[5]  Jon Are Suul,et al.  Wireless Charging for Ships: High-Power Inductive Charging for Battery Electric and Plug-In Hybrid Vessels , 2017, IEEE Electrification Magazine.

[6]  D. A. Frickey Conversions between S, Z, Y, H, ABCD, and T parameters which are valid for complex source and load impedances , 1994 .

[7]  A. Abu-Siada,et al.  Improved power transformer winding fault detection using FRA diagnostics – part 2: radial deformation simulation , 2015, IEEE Transactions on Dielectrics and Electrical Insulation.

[8]  Toit Mouton,et al.  An inductive power tapping (IPT) system for HVDC lines , 2014, 2014 IEEE 5th International Symposium on Power Electronics for Distributed Generation Systems (PEDG).

[9]  A. Abu-Siada,et al.  Improved power transformer winding fault detection using FRA diagnostics – part 1: axial displacement simulation , 2015, IEEE Transactions on Dielectrics and Electrical Insulation.

[10]  Bang-Jun Che,et al.  A Method of Using Nonidentical Resonant Coils for Frequency Splitting Elimination in Wireless Power Transfer , 2015, IEEE Transactions on Power Electronics.

[11]  Masahito Shoyama,et al.  Wireless power transmission using LC cancellation , 2013, 2013 IEEE ECCE Asia Downunder.

[12]  УДК,et al.  System of Transmission of Electrical Energy Specification Forming Part of Letters , 2016 .

[13]  P.T.M. Vaessen,et al.  A new frequency response analysis method for power transformers , 1992 .

[14]  Songcheol Hong,et al.  A Study on Magnetic Field Repeater in Wireless Power Transfer , 2013, IEEE Transactions on Industrial Electronics.

[15]  Gyu-Hyeong Cho,et al.  Innovative 5-m-Off-Distance Inductive Power Transfer Systems With Optimally Shaped Dipole Coils , 2015, IEEE Transactions on Power Electronics.

[16]  Grant Covic,et al.  Inductive Power Transfer , 2013, Proceedings of the IEEE.

[17]  A. Abu-Siada,et al.  Detection of power transformer bushing faults and oil degradation using frequency response analysis , 2016, IEEE Transactions on Dielectrics and Electrical Insulation.

[18]  Grant Covic,et al.  Power transfer capability and bifurcation phenomena of loosely coupled inductive power transfer systems , 2004, IEEE Transactions on Industrial Electronics.

[19]  B. Gustavsen,et al.  Wideband Modeling of Power Transformers Using Commercial sFRA Equipment , 2014, IEEE Transactions on Power Delivery.

[20]  Johann W. Kolar,et al.  Multi-Objective Optimization of 50 kW/85 kHz IPT System for Public Transport , 2016, IEEE Journal of Emerging and Selected Topics in Power Electronics.

[21]  E.P. Dick,et al.  Transformer Diagnostic Testing by Frequuency Response Analysis , 1978, IEEE Transactions on Power Apparatus and Systems.

[22]  S. Y. Ron Hui,et al.  Magnetic Resonance for Wireless Power Transfer [A Look Back] , 2016, IEEE Power Electronics Magazine.

[23]  Seung-Hwan Lee,et al.  Development of 1-MW Inductive Power Transfer System for a High-Speed Train , 2015, IEEE Transactions on Industrial Electronics.

[24]  Weiguo Liu,et al.  Six-Plate Capacitive Coupler to Reduce Electric Field Emission in Large Air-Gap Capacitive Power Transfer , 2018, IEEE Transactions on Power Electronics.

[25]  Eldon J. Rogers,et al.  Instrumentation Techniques for Low Voltage Impulse Testing of Power Transformers , 1972 .

[26]  A. Abu-Siada,et al.  Application of digital image processing to detect transformer bushing faults and oil degradation using FRA polar plot signature , 2017, IEEE Transactions on Dielectrics and Electrical Insulation.

[27]  M. Soljačić,et al.  Wireless Power Transfer via Strongly Coupled Magnetic Resonances , 2007, Science.