Staff extremity doses in interventional radiology. Results of the ORAMED measurement campaign

Abstract The introduction of interventional radiology (IR) procedures in the 20th century has demonstrated significant advantages over surgery procedures. As a result, their number is continuously rising in diagnostic, as well as, in therapy field and is connected with progress in highly sophisticated equipment used for these purposes. Nowadays, in the European countries more than 400 fluoroscopically guided IR procedures were identified with a 10–12% increase in the number of IR examinations every year ( UNSCEAR, 2010 ). Depending on the complexity of the different types of the interventions large differences in the radiation doses of the staff are observed. The staff that carries out IR procedures is likely to receive relatively high radiation doses, because IR procedures require the operator to remain close to the patient and close to the primary radiation beam. In spite of the fact that the operator is shielded by protective apron, the hands, eyes and legs remain practically unshielded. For this reason, one of the aims of the ORAMED project was to provide a set of standardized data on extremity doses for the personnel that are involved in IR procedures and to optimize their protection by evaluating the various factors that affect the doses. In the framework of work package 1 of the ORAMED project the impact of protective equipment, tube configuration and access routes were analyzed for the selected IR procedures. The position of maximum dose measured is also investigated. The results of the extremity doses in IR workplaces are presented in this study together with the influence of the above mentioned parameters on the doses.

[1]  A pilot experience launching a national dose protocol for vascular and interventional radiology. , 2008, Radiation protection dosimetry.

[2]  B. Wall,et al.  Doses to Patients from Medical X-ray Examinations in the UK - 2000 Review , 1996 .

[3]  Haraldur Bjarnason,et al.  An investigation of operator exposure in interventional radiology. , 2006, Radiographics : a review publication of the Radiological Society of North America, Inc.

[4]  M Ginjaume,et al.  An overview on extremity dosimetry in medical applications. , 2008, Radiation protection dosimetry.

[5]  F. Vanhavere,et al.  Extremity and eye lens doses in interventional radiology and cardiology procedures: first results of the ORAMED project. , 2011, Radiation protection dosimetry.

[6]  Filip Vanhavere,et al.  Recommendations to reduce extremity and eye lens doses in interventional radiology and cardiology , 2011 .

[7]  M. P. Judkins,et al.  Transluminal Treatment of Arteriosclerotic Obstruction: Description of a New Technic and a Preliminary Report of Its Application , 1964, Circulation.

[8]  E Vañó,et al.  Radiation exposure to medical staff in interventional and cardiac radiology. , 1998, The British journal of radiology.

[9]  C J Martin,et al.  A study of the distribution of dose across the hands of interventional radiologists and cardiologists. , 2005, The British journal of radiology.

[10]  G. Gualdrini,et al.  Principles for the design and calibration of radiation protection dosemeters for operational and protection quantities for eye lens dosimetry. , 2011, Radiation protection dosimetry.

[11]  J. Valentin,et al.  Abstract: Avoidance of radiation injuries from medical interventional procedures, ICRP Publication 85 , 2000 .