Detection of ochratoxin A (OTA) in coffee using chemiluminescence resonance energy transfer (CRET) aptasensor.

We report a chemiluminescence resonance energy transfer (CRET) aptasensor for the detection of ochratoxin A (OTA) in roasted coffee beans. The aptamer sequences used in this study are 5'-DNAzyme-Linker-OTA aptamer-3'-dabcyl. Dabcyl at the end of the OTA aptamer region plays as a quencher in CRET aptasensor. When hemin and OTA are added, the dabcyl-labeled OTA aptamer approaches to the G-quadruplex-hemin complex by formation of the G-quadruplex-OTA complex. The G-quadruplex-hemin complexes possess horseradish peroxidase (HRP)-like activity, and therefore, the HRP-mimicking DNAzyme (HRPzyme) catalyzes peroxidation in the presence of luminol and H2O2. Resonance energy transfer between luminol (donor) and dabcyl (acceptor) enables quenching of chemiluminescence signals. The signal decreases with increasing the concentration of OTA within the range of 0.1-100ngmL(-1) (limit of detection 0.22ngmL(-1)), and the level of recovery of the respective 1ngmL(-1) and 10ngmL(-1) spiked coffee samples was 71.5% and 93.3%. These results demonstrated the potential of the proposed method for OTA analysis in diverse foods.

[1]  Miao He,et al.  Matrix Effects on the Microcystin-LR Fluorescent Immunoassay Based on Optical Biosensor , 2009, Sensors.

[2]  E. Wang,et al.  Chemiluminescence thrombin aptasensor using high-activity DNAzyme as catalytic label. , 2008, Chemical communications.

[3]  Itamar Willner,et al.  Chemiluminescent and chemiluminescence resonance energy transfer (CRET) detection of DNA, metal ions, and aptamer-substrate complexes using hemin/G-quadruplexes and CdSe/ZnS quantum dots. , 2011, Journal of the American Chemical Society.

[4]  Min-Gon Kim,et al.  A label-free fluorescence immunoassay system for the sensitive detection of the mycotoxin, ochratoxin A. , 2012, Chemical communications.

[5]  Mariana Tozlovanu,et al.  Ochratoxin A in Roasted Coffee from French Supermarkets and Transfer in Coffee Beverages: Comparison of Analysis Methods , 2010, Toxins.

[6]  Min-Gon Kim,et al.  Homogeneous assay of target molecules based on chemiluminescence resonance energy transfer (CRET) using DNAzyme-linked aptamers. , 2013, Biosensors & bioelectronics.

[7]  Jicun Ren,et al.  Gold nanoparticles based chemiluminescent resonance energy transfer for immunoassay of alpha fetoprotein cancer marker. , 2011, Analytica chimica acta.

[8]  Heidi R. C. Dietrich,et al.  Biosensors and multiple mycotoxin analysis , 2003 .

[9]  Liguang Xu,et al.  Fluorescent strip sensor for rapid determination of toxins. , 2011, Chemical communications.

[10]  F. Yu,et al.  Development of a monoclonal antibody against ochratoxin A and its application in enzyme-linked immunosorbent assay and gold nanoparticle immunochromatographic strip. , 2008, Analytical chemistry.

[11]  D M Goldberg,et al.  Assay of ochratoxin A in wine and beer by high-pressure liquid chromatography photodiode array and gas chromatography mass selective detection. , 2001, Journal of agricultural and food chemistry.

[12]  C. O’Sullivan Aptasensors – the future of biosensing? , 2002, Analytical and bioanalytical chemistry.

[13]  Ingrid Bazin,et al.  Rapid Visual Tests: Fast and Reliable Detection of Ochratoxin A , 2010, Toxins.

[14]  Huifeng Qian,et al.  A resonance energy transfer between chemiluminescent donors and luminescent quantum-dots as acceptors (CRET). , 2006, Angewandte Chemie.

[15]  Jean-Louis Marty,et al.  Novel highly-performing immunosensor-based strategy for ochratoxin A detection in wine samples. , 2008, Biosensors & bioelectronics.

[16]  Min-Gon Kim,et al.  Graphene-based chemiluminescence resonance energy transfer for homogeneous immunoassay. , 2012, ACS nano.

[17]  J. Vidal,et al.  An electrochemical competitive biosensor for ochratoxin A based on a DNA biotinylated aptamer. , 2011, Biosensors & bioelectronics.

[18]  J. Marty,et al.  Aptamer-based colorimetric biosensing of Ochratoxin A using unmodified gold nanoparticles indicator. , 2011, Biosensors & bioelectronics.

[19]  Min-Gon Kim,et al.  A label-free, direct and noncompetitive FRET immunoassay for ochratoxin A based on intrinsic fluorescence of an antigen and antibody complex. , 2011, Chemical communications.

[20]  Kun Han,et al.  Design Strategies for Aptamer-Based Biosensors , 2010, Italian National Conference on Sensors.

[21]  Won-Bo Shim,et al.  One-step simultaneous immunochromatographic strip test for multianalysis of ochratoxin a and zearalenone. , 2009, Journal of microbiology and biotechnology.

[22]  X. Le,et al.  Selection and analytical applications of aptamers , 2006 .

[23]  L. Al-Anati,et al.  Immunotoxic activity of ochratoxin A. , 2006, Journal of veterinary pharmacology and therapeutics.

[24]  B Zimmerli,et al.  Determination of ochratoxin A at the ppt level in human blood, serum, milk and some foodstuffs by high-performance liquid chromatography with enhanced fluorescence detection and immunoaffinity column cleanup: methodology and Swiss data. , 1995, Journal of chromatography. B, Biomedical applications.

[25]  A. Wölfling,et al.  Sensitive ELISA Test for Determination of Ochratoxin A , 1996 .

[26]  Ioanis Katakis,et al.  Aptamers: molecular tools for analytical applications , 2008, Analytical and bioanalytical chemistry.

[27]  Yan Jin,et al.  Label-free fluorescent detection of thrombin using G-quadruplex-based DNAzyme as sensing platform. , 2011, The Analyst.

[28]  J. Marty,et al.  Aptamer-DNAzyme hairpins for biosensing of Ochratoxin A. , 2012, Biosensors & bioelectronics.

[29]  Joanna Kosman,et al.  Peroxidase-mimicking DNAzymes for biosensing applications: a review. , 2011, Analytica chimica acta.

[30]  J. Cruz-Aguado,et al.  Determination of ochratoxin a with a DNA aptamer. , 2008, Journal of agricultural and food chemistry.

[31]  I. Willner,et al.  Chemiluminescence and chemiluminescence resonance energy transfer (CRET) aptamer sensors using catalytic hemin/G-quadruplexes. , 2011, ACS nano.

[32]  W. Kong,et al.  Application of aptamer identification technology in rapid analysis of mycotoxins , 2013 .

[33]  Itamar Willner,et al.  DNAzymes for sensing, nanobiotechnology and logic gate applications. , 2008, Chemical Society reviews.

[34]  J Gilbert,et al.  Liquid chromatographic method with immunoaffinity column cleanup for determination of ochratoxin A in barley: collaborative study. , 2000, Journal of AOAC International.