The Long-Term Outcome of Recurrent Defects after Rotator Cuff Repair

Background Retears of the rotator cuff are not uncommon after arthroscopic and mini-open rotator cuff repairs. In most studies, the clinical results in patients with persistent defects demonstrated significantly less pain and better function and strength compared with their preoperative state at an early follow-up. Hypothesis The clinical and structural outcomes of patients with known rotator cuff defects will remain unchanged after a longer period of follow-up. Study Design Case series; Level of evidence, 4. Methods This study was performed in 15 patients (18 shoulders) from a previous study who had recurrent rotator cuff defects 3.2 years after repair. Each patient completed the American Shoulder and Elbow Surgeons Scoring Survey, the Simple Shoulder Test, the L'Insalata Scoring Survey, and a visual analog scale for pain. Eleven patients (13 shoulders) were clinically reexamined at an average of 7.9 years for range of motion and strength, with targeted ultrasound. Results At the 7.9 year follow-up the average scores were 95 (American Shoulder and Elbow Surgeons), 95 (L'Insalata), 11 (Simple Shoulder Test), and 0 (visual analog for pain), which were not statistically significantly different from the scores at 3.2 years. There was no change in the average range of motion; however, there was a statistically significant reduction in forward flexion strength and external rotation strength, as measured by a dynamometer. The average external rotation strength decreased by a mean of 42% and the mean forward flexion strength decreased by a mean of 45% (P < .001). Furthermore, there was a statistically significant increase in the mean size of the defect, from 273 mm2 to 467 mm2 (P < .001). Finally, the size of the defect increased in all patients, and no defects healed structurally. Conclusion At an average of 7.9 years, patients with recurrent defects after rotator cuff repair still had an improvement in terms of pain, function, and satisfaction. However, the rotator cuff defect significantly increased in size, and there was a progression of strength deficits. These findings suggest that patients with recurrent defects can remain asymptomatic over the long term but will predictably lose strength in the involved extremity. Furthermore, the study demonstrated that defects after rotator cuff repair increase in size but often remain asymptomatic.

[1]  P. McClure,et al.  American Shoulder and Elbow Surgeons Standardized Shoulder Assessment Form, patient self-report section: reliability, validity, and responsiveness. , 2002, Journal of shoulder and elbow surgery.

[2]  R. Adler,et al.  All-arthroscopic versus mini-open rotator cuff repair: a retrospective review with minimum 2-year follow-up. , 2006, Arthroscopy : the journal of arthroscopic & related surgery : official publication of the Arthroscopy Association of North America and the International Arthroscopy Association.

[3]  William D Middleton,et al.  The outcome and repair integrity of completely arthroscopically repaired large and massive rotator cuff tears. , 2004, The Journal of bone and joint surgery. American volume.

[4]  C. Gerber,et al.  Clinical Outcome After Structural Failure of Rotator Cuff Repairs* , 2000, The Journal of bone and joint surgery. American volume.

[5]  C. Baker,et al.  Arthroscopically assisted rotator cuff repair: correlation of functional results with integrity of the cuff. , 1994, Arthroscopy : the journal of arthroscopic & related surgery : official publication of the Arthroscopy Association of North America and the International Arthroscopy Association.

[6]  G M Gartsman,et al.  Massive, Irreparable Tears of the Rotator Cuff. Results of Operative Débridement and Subacromial Decompression* , 1997, The Journal of bone and joint surgery. American volume.

[7]  A. Smith Arthroscopic Rotator Cuff Repair: Prospective Evaluation With Sequential Ultrasonography , 2010 .

[8]  K. Yamaguchi,et al.  Ultrasonography of the Rotator Cuff: A Comparison of Ultrasonographic and Arthroscopic Findings in One Hundred Consecutive Cases* , 2000, The Journal of bone and joint surgery. American volume.

[9]  P. Gleyze,et al.  Functional and anatomical results after rotator cuff repair. , 1994, Clinical orthopaedics and related research.

[10]  R. Cofield,et al.  Complications of rotator cuff repair. , 1997, The Orthopedic clinics of North America.

[11]  Peter Reilly,et al.  Supraspinatus tears: propagation and strain alteration. , 2003, Journal of shoulder and elbow surgery.

[12]  C Milgrom,et al.  Rotator-cuff changes in asymptomatic adults. The effect of age, hand dominance and gender. , 1995, The Journal of bone and joint surgery. British volume.

[13]  A. Tomonaga,et al.  Pathology and pathogenesis of the intratendinous tearing of the rotator cuff viewed from en bloc histologic sections. , 1994, Clinical orthopaedics and related research.

[14]  C. Petersson Degeneration of the gleno-humeral joint. An anatomical study. , 1983, Acta orthopaedica Scandinavica.

[15]  Jason S. Lin,et al.  Prospective Evaluation of the Effect of Rotator Cuff Integrity on the Outcome of Open Rotator Cuff Repairs , 2004, The American journal of sports medicine.

[16]  F A Matsen,et al.  Repairs of the rotator cuff. Correlation of functional results with integrity of the cuff. , 1991, The Journal of bone and joint surgery. American volume.

[17]  C. Gerber,et al.  Long-term outcome after structural failure of rotator cuff repairs. , 2006, The Journal of bone and joint surgery. American volume.

[18]  M. Mansat,et al.  [Results of the surgical repair of the rotator cuff. Radio-clinical correlation]. , 1994, Revue de chirurgie orthopedique et reparatrice de l'appareil moteur.

[19]  W. Seitz,et al.  Sonography of the shoulder in patients with tears of the rotator cuff: accuracy and value for selecting surgical options. , 1993, AJR. American journal of roentgenology.

[20]  C. Gerber,et al.  Quantitative assessment of the muscles of the rotator cuff with magnetic resonance imaging. , 1998, Investigative radiology.

[21]  Christian Gerber,et al.  The Results of Repair of Massive Tears of the Rotator Cuff*† , 2000, The Journal of bone and joint surgery. American volume.

[22]  Kurt P. Spindler,et al.  Magnetic resonance imaging of the shoulder. Sensitivity, specificity, and predictive value , 1991 .

[23]  Steven B Cohen,et al.  A Self-Administered Questionnaire for Assessment of Symptoms and Function of the Shoulder* , 1997, The Journal of bone and joint surgery. American volume.

[24]  D Goutallier,et al.  Fatty muscle degeneration in cuff ruptures. Pre- and postoperative evaluation by CT scan. , 1994, Clinical orthopaedics and related research.

[25]  R. Adler,et al.  Prospective analysis of arthroscopic rotator cuff repair: prognostic factors affecting clinical and ultrasound outcome. , 2009, Journal of shoulder and elbow surgery.

[26]  M. Wirth,et al.  Arthroscopic treatment of full-thickness rotator cuff tears: 2- to 7-year follow-up study. , 1993, Arthroscopy : the journal of arthroscopic & related surgery : official publication of the Arthroscopy Association of North America and the International Arthroscopy Association.

[27]  J. O. Søjbjerg,et al.  Functional and magnetic resonance imaging evaluation after single-tendon rotator cuff reconstruction. , 1999, Journal of shoulder and elbow surgery.

[28]  C. Gerber,et al.  MR imaging after rotator cuff repair: full-thickness defects and bursitis-like subacromial abnormalities in asymptomatic subjects , 2000, Skeletal Radiology.

[29]  C. Lehman,et al.  The incidence of full thickness rotator cuff tears in a large cadaveric population. , 1995, Bulletin (Hospital for Joint Diseases (New York, N.Y.)).

[30]  R. Adler,et al.  Ultrasound of Rotator Cuff Tears: Current Status , 2003 .

[31]  K. Yamanaka,et al.  The joint side tear of the rotator cuff. A followup study by arthrography. , 1994, Clinical orthopaedics and related research.

[32]  P. Stefani,et al.  Supraspinatus tendon tears: comparison of US and MR arthrography with surgical correlation , 2002, European Radiology.

[33]  Richard J Hawkins,et al.  Accuracy of magnetic resonance imaging in determining the presence and size of recurrent rotator cuff tears. , 2002, Journal of shoulder and elbow surgery.

[34]  N Morcet,et al.  Prediction of Rotator Cuff Repair Results by Magnetic Resonance Imaging , 1997, Clinical orthopaedics and related research.

[35]  J. Zvijac,et al.  Arthroscopic subacromial decompression in the treatment of full thickness rotator cuff tears: a 3- to 6-year follow-up. , 1994, Arthroscopy : the journal of arthroscopic & related surgery : official publication of the Arthroscopy Association of North America and the International Arthroscopy Association.