Layer thickness in panoramic radiography as defined by different noise-equivalent passbands.

The layer thickness in rotational panoramic radiography is presented with the use of the concept of the noise-equivalent passband. Conventionally, the layer thickness has been calculated only from one-dimensional data in the horizontal or rotational dimension of panoramic radiography. In the present study, results from calculations using both one- and two-dimensional data are presented. When the vertical dimension is included in the calculations, the layer is wider than when calculated from data in the horizontal dimension only. It is pointed out that the wider layer that follows from the introduction of the vertical dimension may be the most reliable measure of layer thickness in panoramic radiography.

[1]  W. McDavid,et al.  Transfer Function Analysis in Rotational Panoramic Radiography , 1983, Acta radiologica: diagnosis.

[2]  Sanderink Gc Imaging characteristics in rotational panoramic radiography. , 1987 .

[3]  U Welander,et al.  An analysis of different planes within the image layer in rotational panoramic radiography. , 1987, Dento maxillo facial radiology.

[4]  W. McDavid,et al.  Resolution of several screen-film combinations in rotational panoramic radiography. , 1986, Oral surgery, oral medicine, and oral pathology.

[5]  W. McDavid,et al.  Blurring effects in rotational panoramic radiography. , 1982, Oral surgery, oral medicine, and oral pathology.

[6]  R. F. Wagner,et al.  Toward a unified view of radiological imaging systems. Part II: Noisy images , 1974 .

[7]  W. McDavid,et al.  A new method for image layer analysis in rotational panoramic radiography. , 1981, Oral surgery, oral medicine, and oral pathology.

[8]  C. Moore,et al.  A suggested theory of the conventional tomographic imaging process. , 1981, Physics in medicine and biology.

[9]  W. McDavid,et al.  Definitions of unsharpness and layer thickness in rotational panoramic radiography. , 1984, Oral surgery, oral medicine, and oral pathology.

[10]  R. F. Wagner,et al.  Toward a unified view of radiological imaging systems. Part II: Noisy images. , 1977, Medical physics.

[11]  Otto H. Schade Image Gradation, Graininess and Sharpness in Television and Motion-Picture Systems: Part IV, A & B: Image Analysis in Photographic and Television Systems (Definition and Sharpness) , 1955 .

[12]  Otto H. Schade Evaluation Of Noisy Images , 1974, Other Conferences.

[13]  U. Welander,et al.  Position, Form, and Thickness of the Image Layer in Narrow Beam Rotation Radiography , 1978, Acta radiologica: diagnosis.

[14]  Otto H. Schade Image Gradation, Graininess and Sharpness in Television and Motion Picture Systems: Part II: The Grain Structure of Motion Picture Images—An Analysis of Deviations and Fluctuations of the Sample Number , 1952 .

[15]  W. McDavid,et al.  The effect of system parameters on resolution in rotational panoramic radiography. A mathematical analysis. , 1989, Dento maxillo facial radiology.

[16]  U. Rao,et al.  Gaussian and Exponential Approximations of the Modulation Transfer Function , 1967 .

[17]  A. L. Evans,et al.  The Evaluation of Medical Images , 1981 .

[18]  U. Welander,et al.  Blurring and Layer Thickness in Narrow Beam Rotation Radiography , 1977, Acta radiologica: diagnosis.