Data‐driven optimal binning for respiratory motion management in PET

PURPOSE Respiratory gating has been used in PET imaging to reduce the amount of image blurring caused by patient motion. Optimal binning is an approach for using the motion-characterized data by binning it into a single, easy to understand/use, optimal bin. To date, optimal binning protocols have utilized externally driven motion characterization strategies that have been tuned with population-derived assumptions and parameters. In this work, we are proposing a new strategy with which to characterize motion directly from a patient's gated scan, and use that signal to create a patient/instance-specific optimal bin image. METHODS Two hundred and nineteen phase-gated FDG PET scans, acquired using data-driven gating as described previously, were used as the input for this study. For each scan, a phase-amplitude motion characterization was generated and normalized using principle component analysis. A patient-specific "optimal bin" window was derived using this characterization, via methods that mirror traditional optimal window binning strategies. The resulting optimal bin images were validated by correlating quantitative and qualitative measurements in the population of PET scans. RESULTS In 53% (n = 115) of the image population, the optimal bin was determined to include 100% of the image statistics. In the remaining images, the optimal binning windows averaged 60% of the statistics and ranged between 20% and 90%. Tuning the algorithm, through a single acceptance window parameter, allowed for adjustments of the algorithm's performance in the population toward conservation of motion or reduced noise-enabling users to incorporate their definition of optimal. In the population of images that were deemed appropriate for segregation, average lesion SUV max were 7.9, 8.5, and 9.0 for nongated images, optimal bin, and gated images, respectively. The Pearson correlation of FWHM measurements between optimal bin images and gated images were better than with nongated images, 0.89 and 0.85, respectively. Generally, optimal bin images had better resolution than the nongated images and better noise characteristics than the gated images. DISCUSSION We extended the concept of optimal binning to a data-driven form, updating a traditionally one-size-fits-all approach to a conformal one that supports adaptive imaging. This automated strategy was implemented easily within a large population and encapsulated motion information in an easy to use 3D image. Its simplicity and practicality may make this, or similar approaches ideal for use in clinical settings.

[1]  Florian Büther,et al.  On transcending the impasse of respiratory motion correction applications in routine clinical imaging - a consideration of a fully automated data driven motion control framework , 2014, EJNMMI Physics.

[2]  Marc Faraggi,et al.  Impact of a new respiratory amplitude-based gating technique in evaluation of upper abdominal PET lesions. , 2014, European journal of radiology.

[3]  Claudia Kuntner,et al.  A new fast and fully automated software based algorithm for extracting respiratory signal from raw PET data and its comparison to other methods. , 2010, Medical physics.

[4]  Darrell Burckhardt,et al.  Validation of Software Gating: A Practical Technology for Respiratory Motion Correction in PET. , 2016, Radiology.

[5]  S. Hapdey,et al.  Management of respiratory motion in PET/computed tomography: the state of the art , 2014, Nuclear medicine communications.

[6]  Valentino Bettinardi,et al.  Respiratory gated PET/CT in a European multicentre retrospective study: added diagnostic value in detection and characterization of lung lesions , 2012, European Journal of Nuclear Medicine and Molecular Imaging.

[7]  Florian Büther,et al.  Impact of Data-driven Respiratory Gating in Clinical PET. , 2016, Radiology.

[8]  Paul E Kinahan,et al.  Respiratory motion correction for quantitative PET/CT using all detected events with internal-external motion correlation. , 2011, Medical physics.

[9]  A. Chi,et al.  4D PET/CT as a Strategy to Reduce Respiratory Motion Artifacts in FDG-PET/CT , 2014, Front. Oncol..

[10]  Doumit Daou,et al.  Respiratory motion handling is mandatory to accomplish the high-resolution PET destiny , 2008, European Journal of Nuclear Medicine and Molecular Imaging.

[11]  Adam Leon Kesner The relevance of data driven motion correction in diagnostic PET , 2017, European Journal of Nuclear Medicine and Molecular Imaging.

[12]  J. Humm,et al.  Using an external gating signal to estimate noise in PET with an emphasis on tracer avid tumors , 2010, Physics in medicine and biology.

[13]  Habib Zaidi,et al.  Strategies for Motion Tracking and Correction in PET. , 2007, PET clinics.

[14]  Loïc Fin,et al.  Improved attenuation correction via appropriate selection of respiratory-correlated PET data , 2008, Comput. Methods Programs Biomed..

[15]  O. Schober,et al.  Respiratory gating in positron emission tomography: a quantitative comparison of different gating schemes. , 2007, Medical physics.

[16]  Andrea Lupi,et al.  The effect of 18F-FDG-PET/CT respiratory gating on detected metabolic activity in lung lesions , 2009, Annals of nuclear medicine.

[17]  Paul E Kinahan,et al.  The impact of respiratory motion on tumor quantification and delineation in static PET/CT imaging , 2009, Physics in medicine and biology.

[18]  Drew A. Torigian,et al.  Repeatability of 18F-FDG PET/CT in Advanced Non–Small Cell Lung Cancer: Prospective Assessment in 2 Multicenter Trials , 2015, The Journal of Nuclear Medicine.

[19]  C. Ling,et al.  Effect of respiratory gating on reducing lung motion artifacts in PET imaging of lung cancer. , 2002, Medical physics.

[20]  James Hamill,et al.  Optimal gating compared to 3D and 4D PET reconstruction for characterization of lung tumours , 2011, European Journal of Nuclear Medicine and Molecular Imaging.

[21]  Xiao Jin,et al.  Data-driven event-by-event respiratory motion correction using TOF PET list-mode centroid of distribution , 2017, Physics in medicine and biology.

[22]  A J Reader,et al.  List-mode-based reconstruction for respiratory motion correction in PET using non-rigid body transformations , 2007, Physics in medicine and biology.

[23]  Kris Thielemans,et al.  Quiescent period respiratory gating for PET/CT. , 2010, Medical physics.

[24]  Paul K Marsden,et al.  Impact of respiratory motion correction and spatial resolution on lesion detection in PET: a simulation study based on real MR dynamic data , 2014, Physics in medicine and biology.

[25]  Mark Lubberink,et al.  Quantification, improvement, and harmonization of small lesion detection with state-of-the-art PET , 2017, European Journal of Nuclear Medicine and Molecular Imaging.

[26]  V. Bettinardi,et al.  Detection and compensation of organ/lesion motion using 4D-PET/CT respiratory gated acquisition techniques. , 2010, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.