Energy harvesting by implantable abiotically catalyzed glucose fuel cells

Implantable glucose fuel cells are a promising approach to realize an autonomous energy supply for medical implants that solely relies on the electrochemical reaction of oxygen and glucose. Key advantage over conventional batteries is the abundant availability of both reactants in body fluids, rendering the need for regular replacement or external recharging mechanisms obsolete. Implantable glucose fuel cells, based on abiotic catalysts such as noble metals and activated carbon, have already been developed as power supply for cardiac pacemakers in the late-1960s. Whereas, in vitro and preliminary in vivo studies demonstrated their long-term stability, the performance of these fuel cells is limited to the μW-range. Consequently, no further developments have been reported since high-capacity lithium iodine batteries for cardiac pacemakers became available in the mid-1970s. In recent years research has been focused on enzymatically catalyzed glucose fuel cells. They offer higher power densities than their abiotically catalyzed counterparts, but the limited enzyme stability impedes long-term application. In this context, the trend towards increasingly energy-efficient low power MEMS (micro-electro-mechanical systems) implants has revived the interest in abiotic catalysts as a long-term stable alternative. This review covers the state-of-the-art in implantable abiotically catalyzed glucose fuel cells and their development since the 1960s. Different embodiment concepts are presented and the historical achievements of academic and industrial research groups are critically reviewed. Special regard is given to the applicability of the concept as sustainable micro-power generator for implantable devices.

[1]  Animal experiments with biogalvanic and biofuel cells. , 1976, Biomaterials, medical devices, and artificial organs.

[2]  Hubert A. Gasteiger,et al.  Handbook of fuel cells : fundamentals technology and applications , 2003 .

[3]  R. Drake,et al.  Studies of Electrooxidation of Dextrose in Neutral Media , 1969 .

[4]  S. Saeger,et al.  An electrocatalytic glucose sensor for in-vivo application. , 1991, Biomedical instrumentation & technology.

[5]  A. Tseung,et al.  Some studies related to electricity generation from biological fuel cells and galvanic cells,in vitro andin vivo , 2007, Medical and biological engineering.

[6]  V Parsonnet,et al.  Power sources for implantable cardiac pacemakers. , 1972, Chest.

[7]  S. Affrossman,et al.  Biological Fuel Cell Incorporating a Selective Anode Catalyst , 1976 .

[8]  A. K. Shukla,et al.  Biological fuel cells and their applications , 2004 .

[9]  S. J. Yao,et al.  Glucose sensing in the low and negative region: utilization of a thin-film electrode , 1991 .

[10]  V Parsonnet,et al.  Cardiac pacing, 1960-1985: a quarter century of medical and industrial innovation. , 1998, Circulation.

[11]  N. Kabei,et al.  Development of an electrostatic generator for a cardiac pacemaker that harnesses the ventricular wall motion , 2002, Journal of Artificial Organs.

[12]  F C Walsh,et al.  Biofuel cells and their development. , 2006, Biosensors & bioelectronics.

[13]  D. Gough,et al.  Effect of coreactants on electrochemical glucose oxidation , 1978 .

[14]  A. Appleby,et al.  Parametric study of the anode of an implantable biological fuel cell , 1971 .

[15]  T. K. Hunt,et al.  Direct measurement of wound and tissue oxygen tension in postoperative patients. , 1983, Annals of surgery.

[16]  R. Brodd,et al.  Electrode Materials and Catalysts for Oxygen Reduction in Isotonic Saline Solution , 1970 .

[17]  A. Heller Miniature biofuel cells , 2004 .

[18]  T. Perry,et al.  Technical pitfalls leading to errors in the quantitation of plasma amino acids. , 1969, Clinica chimica acta; international journal of clinical chemistry.

[19]  R. Brodd,et al.  Oxygen and Hydrogen Peroxide Reduction at a Ferric Phthalocyanine‐Catalyzed Graphite Electrode , 1970 .

[20]  G. Arzoumanidis,et al.  Electrocataytic oxidation of D-glucose in neutral media with electrodes catalyzed by 4,4',4'', 4'''-tetrasulfophthalocyanine , 1969 .

[21]  W Greatbatch,et al.  The solid-state lithium battery: a new improved chemical power source for implantable cardiac pacemakers. , 1971, IEEE transactions on bio-medical engineering.

[22]  A. Arvia,et al.  Potentiodynamic Study of Glucose Electro‐Oxidation at Bright Platinum Electrodes , 1982 .

[23]  S. Affrossman,et al.  Biological fuel cell incorporating selective membranes , 1975, Medical and biological engineering.

[24]  Anthony Turner,et al.  Biosensors and Biofuel Cells , 1984 .

[25]  Shadrach Roundy,et al.  On the Effectiveness of Vibration-based Energy Harvesting , 2005 .

[26]  G Richter,et al.  Metal-oxygen and glucose-oxygen cells for implantable devices. , 1974, Biomedical engineering.

[27]  Martin Blank,et al.  Bioelectrochemistry I : biological redox reactions , 1983 .

[28]  R. Erbel,et al.  Microgenerators for Energy Autarkic Pacemakers and Defibrillators: Fact or Fiction? , 2001, Herz.

[29]  E. Gileadi,et al.  Anodic oxidation of cellulose and lower carbohydrates , 1964 .

[30]  F. Sturm,et al.  The performance of glucose electrodes and the characteristics of different biofuel cell constructions , 1976 .

[31]  G. Richter,et al.  Implantable bio-electrochemical power sources , 1974, Naturwissenschaften.

[32]  C. Swahn,et al.  The Inhibition of the Electrochemical Oxidation of Glucose at Platinum at pH = 7.4 by Chloride Ions. , 1973 .

[33]  U. Gebhardt,et al.  A special type of raney-alloy catalyst used in compact biofuel cells , 1976 .

[34]  S. J. Yao,et al.  Anodic Oxidation of Carbohydrates and their Derivatives in Neutral Saline Solution , 1969, Nature.

[35]  A. Arvia,et al.  Comparative study of the electrochemical behaviour of glucose and other compounds of biological interest , 1982 .

[36]  N. Mano,et al.  Characteristics of a miniature compartment-less glucose-O2 biofuel cell and its operation in a living plant. , 2003, Journal of the American Chemical Society.

[37]  Adam Heller,et al.  Potentially implantable miniature batteries , 2006, Analytical and bioanalytical chemistry.

[38]  유영제,et al.  Biotechnology에서 배우는 교훈 , 2006 .

[39]  C. Colton,et al.  Electrochemical Glucose Oxidation on a Platinized Platinum Electrode in Krebs‐Ringer Solution IV . Effect of Amino Acids , 1981 .

[40]  Yu.B. Vassilyev,et al.  Kinetics and mechanism of glucose electrooxidation on different electrode-catalysts: Part II. Effect of the nature of the electrode and the electrooxidation mechanism , 1985 .

[41]  Bernard H. Stark,et al.  Mems inertial power generators for biomedical applications , 2006 .

[42]  B. Beden,et al.  On line chromatographic analysis of the products resulting from the electrocatalytic oxidation of D-glucose on Pt, Au and adatoms modified Pt electrodes. Part I : Acid and neutral media , 1992 .

[43]  L.S.Y. Wong,et al.  A very low-power CMOS mixed-signal IC for implantable pacemaker applications , 2004, IEEE Journal of Solid-State Circuits.

[44]  G. Luft,et al.  Electrochemical behavior of amino acids and their influence on the anodic oxidation of glucose in neutral media. , 1978, Biomaterials, medical devices, and artificial organs.

[45]  H. Bremer Disturbances of amino acid metabolism : clinical chemistry and diagnosis , 1981 .

[46]  Kiichi Tsuchiya,et al.  Development of an Electrostatic Generator that Harnesses the Motion of a Living Body : Use of a Resonant Phenomenon , 2000 .

[47]  W. Tamborlane,et al.  Interstitial fluid concentrations of glycerol, glucose, and amino acids in human quadricep muscle and adipose tissue. Evidence for significant lipolysis in skeletal muscle. , 1995, The Journal of clinical investigation.

[48]  D. Stetten,et al.  The metabolism of gluconic acid. , 1950, The Journal of biological chemistry.

[49]  Rahul Sarpeshkar,et al.  An ultra-low-power programmable analog bionic ear processor , 2005, IEEE Transactions on Biomedical Engineering.

[50]  Scott Calabrese Barton,et al.  Enzymatic biofuel cells for implantable and microscale devices. , 2004, Chemical reviews.

[51]  C. Colton,et al.  Electrochemical Glucose Oxidation on a Platinized Platinum Electrode in Krebs‐Ringer Solution II . Potentiostatic Studies , 1979 .

[52]  O. Siggaard‐Andersen,et al.  Composition of interstitial fluid. , 1995, Clinical chemistry.

[53]  Frank Davis,et al.  Biofuel cells--recent advances and applications. , 2007, Biosensors & bioelectronics.

[54]  Yu.B. Vassilyev,et al.  Kinetics and mechanism of glucose electrooxidation on different electrode-catalysts: Part I. Adsorption and oxidation on platinum , 1985 .