Combination of pulsed-wave Doppler and real-time three-dimensional color Doppler echocardiography for quantifying the stroke volume in the left ventricular outflow tract.

Real-time three-dimensional (3-D) color Doppler echocardiography (RT3D) is capable of quantifying flow. However, low temporal resolution limits its application to stroke volume (SV) measurements. The aim of the present study was, therefore, to develop a reliable method to quantify SV. In animal experiments, cross-sectional images of the LV outflow tract were selected from the RT3D data to calculate peak flow rates (Q(p3D)). Conventional pulsed-wave (PW) Doppler was performed to measure the velocity-time integral (VTI) and the peak velocity (V(p)). By assuming that the flow is proportional to the velocity temporal waveform, SV was calculated as alpha x Q(p3D) x VTI/V(p), where alpha is a temporal correction factor. There was an excellent correlation between the reference flow meter and RT3D SV (mean difference = -1. 3 mL, y = 1. 05 x -2. 5, r = 0. 94, p < 0. 01). The new method allowed accurate SV estimations without any geometric assumptions of the spatial velocity distributions.

[1]  J. Thomas,et al.  Real-time three-dimensional color Doppler echocardiography for characterizing the spatial velocity distribution and quantifying the peak flow rate in the left ventricular outflow tract. , 2001, Ultrasound in medicine & biology.

[2]  T. Shiota Automated cardiac flow measurement by digital colour Doppler echocardiography , 2002, Heart.

[3]  Yoshiki Mori,et al.  Direct quantification of transmitral flow volume with dynamic 3-dimensional digital color Doppler: a validation study in an animal model. , 2002, Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography.

[4]  D. Altman,et al.  STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT , 1986, The Lancet.

[5]  B Wranne,et al.  Subaortic flow profiles in aortic valve disease: a two-dimensional color Doppler study. , 1994, Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography.

[6]  J D Thomas,et al.  Automated cardiac output measurement by spatiotemporal integration of color Doppler data. In vitro and clinical validation. , 1997, Circulation.

[7]  D J Sahn,et al.  The Effect of Variations on Pulsed Doppler Sampling Site on Calculation of Cardiac Output: An Experimental Study in Open‐chest Dogs , 1983, Circulation.

[8]  M Jones,et al.  Calculation of aortic regurgitant volume by a new digital Doppler color flow mapping method: an animal study with quantified chronic aortic regurgitation. , 1997, Journal of the American College of Cardiology.

[9]  H. Torp,et al.  Measurement of volumetric mitral and aortic blood flow based on a new freehand three-dimensional colour flow imaging method. An in vivo validation. , 2000, European journal of echocardiography : the journal of the Working Group on Echocardiography of the European Society of Cardiology.

[10]  H P Meinzer,et al.  Three-dimensional color Doppler: a clinical study in patients with mitral regurgitation. , 1999, Journal of the American College of Cardiology.

[11]  V. Poutanen,et al.  Cross sectional profiles of systolic flow velocities in left ventricular outflow tract of normal subjects. , 1995, British heart journal.

[12]  N C Nanda,et al.  Accuracy of color doppler velocity in the flow field proximal to a regurgitant orifice: implications for color doppler quantitation of valvular incompetence. , 1996, Ultrasound in medicine & biology.

[13]  M Jones,et al.  Validation of the accuracy of both right and left ventricular outflow volume determinations and semiautomated calculation of shunt volumes through atrial septal defects by digital color Doppler flow mapping in a chronic animal model. , 1999, Journal of the American College of Cardiology.

[14]  H. Tsujino,et al.  Quantitative measurement of volume flow rate (cardiac output) by the multibeam Doppler method. , 1995, Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography.

[15]  A. Zetts,et al.  Impact of temporal resolution on flow quantification by real-time 3D color Doppler echocardiography: numerical modeling and animal validation study , 2000, Computers in Cardiology 2000. Vol.27 (Cat. 00CH37163).

[16]  M Jones,et al.  A comparison of failure modes of glutaraldehyde-treated versus antibiotic-preserved mitral valve allografts implanted in sheep. , 1995, The Journal of thoracic and cardiovascular surgery.

[17]  A. Beckett,et al.  AKUFO AND IBARAPA. , 1965, Lancet.

[18]  L L Huntsman,et al.  Noninvasive Doppler Determination of Cardiac Output in Man: Clinical Validation , 1983, Circulation.