Chronic Performance of a Subcutaneous Hemodynamic Sensor

Background: A subcutaneous photoplethysmography (PPG) sensor uses light to detect changes in vascular volume from a location outside the bloodstream. Incorporation into a chronically implanted device, such as a pacemaker or an implantable cardioverter defibrillator, may facilitate therapy optimization and disease monitoring by providing continuous assessment of hemodynamic function and arterial oxygen saturation. However, performance of a chronically placed subcutaneous sensor has not been established.

[1]  R. Anderson,et al.  The optics of human skin. , 1981, The Journal of investigative dermatology.

[2]  Robert G. Turcott,et al.  Hemodynamic sensing using subcutaneous photoplethysmography. , 2008, American journal of physiology. Heart and circulatory physiology.

[3]  M. Südkamp,et al.  Perioperative hemodynamic measurements with an implantable monitoring system (Chronicle®) in a patient with severe heart failure undergoing non-cardiac surgery , 2004, Zeitschrift für Kardiologie.

[4]  G. Kay,et al.  Two‐Year Experience with Rate‐Modulated Pacing Controlled by Mixed Venous Oxygen Saturation , 1998, Pacing and clinical electrophysiology : PACE.

[5]  D. Kristo,et al.  Overnight pulse oximetry for sleep-disordered breathing in adults: a review. , 2001, Chest.

[6]  J. Sinex Pulse oximetry: principles and limitations. , 1999, The American journal of emergency medicine.

[7]  L Stangeland,et al.  Long‐Term Clinical Performance of a Central Venous Oxygen Saturation Sensor for Rate Adaptive Cardiac Pacing , 1994, Pacing and clinical electrophysiology : PACE.

[8]  L. Rydén,et al.  Ongoing right ventricular hemodynamics in heart failure: clinical value of measurements derived from an implantable monitoring system. , 2003, Journal of the American College of Cardiology.

[9]  Ross Flewelling,et al.  Noninvasive Optical Monitoring , 1999 .

[10]  H F Mahieu,et al.  Photoelectric plethysmography--some fundamental aspects of the reflection and transmission method. , 1981, Clinical physics and physiological measurement : an official journal of the Hospital Physicists' Association, Deutsche Gesellschaft fur Medizinische Physik and the European Federation of Organisations for Medical Physics.

[11]  J. Weinman,et al.  Reflection photoplethysmography of arterial-blood-volume pulses , 2006, Medical and Biological Engineering and Computing.

[12]  R. Graaff,et al.  Effect of location of the sensor on reflectance pulse oximetry , 1997, British journal of obstetrics and gynaecology.

[13]  P. Larsen,et al.  Spectral analysis of AC and DC components of the pulse photoplethysmograph at rest and during induction of anaesthesia , 1997, International journal of clinical monitoring and computing.

[14]  R. Turcott,et al.  Identification of Hemodynamically Unstable Arrhythmias Using Subcutaneous Photoplethysmography , 2010, Journal of cardiovascular electrophysiology.

[15]  W. B. Murray,et al.  The peripheral pulse wave: Information overlooked , 1996, Journal of clinical monitoring.

[16]  Monitoring heart failure hemodynamics with an implanted device: its potential to improve outcome. , 2003, Journal of the American College of Cardiology.

[17]  M J Dennis Plethysmography: the new wave in haemodynamic monitoring--a review of clinical applications. , 2000, Australian critical care : official journal of the Confederation of Australian Critical Care Nurses.