Power Quality Improvement by using Shunt Active Power Filter at Various Load Conditions Using Source Side Sensing Control

Power quality problems such as three-phase unbalanced and harmonics, reactive power, power factor and so on, have become serious increasingly, passive power filter may not provide better solution and the development of APF has been one of the ways to solve these problems. This paper presents a three-phase, 3-level voltage source inverter based active filter for power line conditioning to improve power quality in the distribution network. The active filter compensates both reactive power and harmonic currents drawn by non-linear loads; additionally it facilitates power factor corrections. The compensation process is based on concept of source side sensing. This proposed 3-level active power filter system is validated through MATLAB/SIMULINK Platform with different load conditions.

[1]  W. M. Grady,et al.  Survey of active power line conditioning methodologies , 1990 .

[2]  P Karuppanan,et al.  Shunt Active Power Line Conditioners for compensating harmonics and reactive power , 2010, 2010 9th International Conference on Environment and Electrical Engineering.

[3]  Hirofumi Akagi,et al.  Instantaneous Reactive Power Compensators Comprising Switching Devices without Energy Storage Components , 1984, IEEE Transactions on Industry Applications.

[4]  Fang Zheng Peng,et al.  Reactive power and harmonic compensation based on the generalized instantaneous reactive power theory for three-phase power systems , 1996 .

[5]  Arindam Ghosh,et al.  Switching Characterization of Cascaded Multilevel-Inverter-Controlled Systems , 2008, IEEE Transactions on Industrial Electronics.

[6]  L. Gyugyi,et al.  Active ac power filters , 1976 .

[7]  L.S. Czarnecki,et al.  Instantaneous reactive power p-q theory and power properties of three-phase systems , 2006, IEEE Transactions on Power Delivery.

[8]  Hirofumi Akagi,et al.  Control Strategy of Active Power Filters Using Multiple Voltage-Source PWM Converters , 1986, IEEE Transactions on Industry Applications.

[9]  Shyh-Jier Huang,et al.  Design and operation of cascaded active power filters for the reduction of harmonic distortions in a power system , 1999 .

[10]  Júlio S. Martins,et al.  Active filters with control based on the p-q theory , 2000 .

[11]  Hirofumi Akagi Trends in active power line conditioners , 1994 .

[12]  D. J. Adams,et al.  A power line conditioner using cascade multilevel inverters for distribution systems , 1997, IAS '97. Conference Record of the 1997 IEEE Industry Applications Conference Thirty-Second IAS Annual Meeting.

[13]  Mariusz Malinowski,et al.  A Survey on Cascaded Multilevel Inverters , 2010, IEEE Transactions on Industrial Electronics.

[14]  W. M. Grady,et al.  Meeting IEEE-519 harmonic voltage and voltage distortion constraints with an active power line conditioner , 1994 .

[15]  Mauricio Aredes,et al.  New concepts of instantaneous active and reactive powers in electrical systems with generic loads , 1993 .