Ecology of Legionella pneumophila within water distribution systems

The reservoir for hospital-acquired Legionnaires disease has been shown to be the potable water distribution system. We investigated the influence of the natural microbial population and sediment (scale and organic particulates) found in water systems as growth-promoting factors for Legionella pneumophila. Our in vitro experiments showed that: (i) water from hot-water storage tank readily supported the survival of L. pneumophila, (ii) the concentration of sediment was directly related to the survival of L. pneumophila, (iii) the presence of environmental bacteria improved the survival of L. pneumophila via nutritional symbiosis, (iv) the combination of sediment and environmental bacteria acted synergistically to improve the survival of L. pneumophila, and (v) the role of sediment in this synergistic effect was determined to be nutritional. Sediment was found to stimulate the growth of environmental microflora, which in turn stimulated the growth of L. pneumophila. These findings confirm the empiric observations of the predilection of L. pneumophila for growth in hot-water tanks and its localization to sediment. L. pneumophila occupies an ecological niche within the potable water system, with interrelationships between microflora, sediment, and temperature.

[1]  C. Fliermans,et al.  Ecological distribution of Legionella pneumophila , 1981, Applied and environmental microbiology.

[2]  M. Blaser,et al.  Growth, survival, and resistance of the Legionnaires' disease bacterium. , 1979, Annals of internal medicine.

[3]  R M Wadowsky,et al.  Multiplication of Legionella pneumophila in unsterilized tap water , 1982, Applied and environmental microbiology.

[4]  R. Wadowsky,et al.  Satellite growth of Legionella pneumophila with an environmental isolate of Flavobacterium breve , 1983, Applied and environmental microbiology.

[5]  R. J. Gibson,et al.  Charcoal-yeast extract agar: primary isolation medium for Legionella pneumophila , 1979, Journal of clinical microbiology.

[6]  V. Yu,et al.  Ubiquitousness of Legionella pneumophila in the water supply of a hospital with endemic Legionnaires' disease. , 1982, The New England journal of medicine.

[7]  V. Yu,et al.  LEGIONELLACEAE IN THE HOSPITAL WATER-SUPPLY Epidemiological Link with Disease and Evaluation of a Method for Control of Nosocomial Legionnaires' Disease and Pittsburgh Pneumonia , 1983, The Lancet.

[8]  R. Fallon,et al.  Legionnaires' disease: further evidence to implicate water storage and distribution systems as sources. , 1981, British medical journal.

[9]  T. Rowbotham Preliminary report on thepathogenicity ofLegionella pneumophila forfreshwater andsoil amoebae , 1980 .

[10]  Dahlem Konferenzen,et al.  Strategies of microbial life in extreme environments : report of the Dahlem Workshop on Strategy of Life in Extreme Environments, Berlin, 1978, November 20-24 , 1979 .

[11]  T. Rowbotham,et al.  Preliminary report on the pathogenicity of Legionella pneumophila for freshwater and soil amoebae. , 1980, Journal of clinical pathology.

[12]  C. Fliermans,et al.  Isolation of Legionella pneumophila from nonepidemic-related aquatic habitats. , 1979, Applied and environmental microbiology.

[13]  J. Plouffe,et al.  Relationship between colonization of hospital building with Legionella pneumophila and hot water temperatures , 1983, Applied and environmental microbiology.

[14]  J. A. Taylor,et al.  LEGIONELLA PNEUMOPHILA IN WATER PLUMBING SYSTEMS , 1982, The Lancet.

[15]  V. Yu,et al.  POTABLE WATER SUPPLY AS THE HOSPITAL RESERVOIR FOR PITTSBURGH PNEUMONIA AGENT , 1982, The Lancet.

[16]  P. Skaliy,et al.  Survival of the Legionnaires' disease bacterium in water. , 1979, Annals of internal medicine.

[17]  R. J. Gibson,et al.  Pittsburgh pneumonia agent: direct isolation from human lung tissue. , 1980, The Journal of infectious diseases.

[18]  E. Steers,et al.  An inocula replicating apparatus for routine testing of bacterial susceptibility to antibiotics. , 1959, Antibiotics & chemotherapy.

[19]  J. Dowling,et al.  Hot water systems as sources of Legionella pneumophila in hospital and nonhospital plumbing fixtures , 1982, Applied and environmental microbiology.

[20]  C. Fliermans,et al.  Growth of Legionella pneumophila in association with blue-green algae (cyanobacteria) , 1980, Applied and environmental microbiology.

[21]  Cyanobacterial stimulation of growth and oxygen uptake by Legionella pneumophila , 1983, Applied and environmental microbiology.