The Advanced Radiographic Capability, A Major Upgrade Of The Computer Controls For The National Ignition Facility*

The Advanced Radiographic Capability (ARC) currently under development for the National Ignition Facility (NIF) will provide short (1-50 picoseconds) ultra high power (>1 Petawatt) laser pulses used for a variety of diagnostic purposes on NIF ranging from a high energy xray pulse source for backlighter imaging to an experimental platform for fast-ignition. A single NIF Quad (4 beams) is being upgraded to support experimentally driven, autonomous operations using either ARC or existing NIF pulses. Using its own seed oscillator, ARC generates short, wide bandwidth pulses that propagate down the existing NIF beamlines for amplification before being redirected through large aperture gratings that perform chirped pulse compression, generating a series of high-intensity pulses within the target chamber. This significant effort to integrate the ARC adds 70% additional control points to the existing NIF Quad and will be deployed in several phases over the coming year. This talk discusses some new unique ARC software controls used for short pulse operation on NIF and integration techniques being used to expedite deployment of this new diagnostic.