Two-fluid non-linear model for flow in catheterized blood vessels

Abstract Blood flow through a catheterized artery is analyzed, assuming the flow is steady and blood is treated as a two-fluid model with the suspension of all the erythrocytes in the core region as a Casson fluid and the plasma in the peripheral region as a Newtonian fluid. The expressions for velocity, flow rate, wall shear stress and frictional resistance are obtained. The variations of these flow quantities with yield stress, catheter radius ratio and peripheral layer thickness are discussed. It is noticed that the velocity and flow rate decrease while the wall shear stress and resistance to flow increase when the yield stress or the catheter radius ratio increases while all the other parameters were held fixed. It is found that the velocity and flow rate increase while the wall shear stress and frictional resistance decrease with the increase of the peripheral layer thickness. The estimates of the increase in the frictional resistance are significantly very small for the present two-fluid model than those of the single-fluid Casson model.

[1]  K. Rajagopal,et al.  A Model for the Formation and Lysis of Blood Clots , 2006, Pathophysiology of Haemostasis and Thrombosis.

[2]  V P Srivastava,et al.  Two-layered model of Casson fluid flow through stenotic blood vessels: applications to the cardiovascular system. , 1994, Journal of biomechanics.

[3]  M. Panteleev,et al.  Mathematical models of blood coagulation and platelet adhesion: clinical applications. , 2007, Current pharmaceutical design.

[4]  V. P. Srivastava Two-phase model of blood flow through stenosed tubes in the presence of a peripheral layer: applications. , 1996, Journal of biomechanics.

[5]  P. K. Mandal An unsteady analysis of nonlinear two‐layered 2D model of pulsatile flow through stenosed arteries 1 , 2003 .

[6]  E. Deutsch Flow Properties of Blood and Other Biological Systems , 1961 .

[7]  Kumbakonam R. Rajagopal,et al.  A Model Incorporating Some of the Mechanical and Biochemical Factors Underlying Clot Formation and Dissolution in Flowing Blood , 2003 .

[8]  Liviu Moraru,et al.  Catheter-based impedance measurements in the right atrium for continuously monitoring hematocrit and estimating blood viscosity changes; an in vivo feasibility study in swine. , 2004, Biosensors & bioelectronics.

[9]  A. I. Lobanov,et al.  Spatio-Temporal Dynamics of Blood coagulation and Pattern Formation: a Theoretical Approach , 2002, Int. J. Bifurc. Chaos.

[10]  J F Gross,et al.  Pulsatile flow in small blood vessels. I. Casson theory. , 1972, Biorheology.

[11]  G Jayaraman,et al.  Correction to flow rate--pressure drop relation in coronary angioplasty: steady streaming effect. , 1998, Journal of biomechanics.

[12]  G. Thurston,et al.  Rheological parameters for the viscosity viscoelasticity and thixotropy of blood. , 1979, Biorheology.

[13]  K. Rajagopal,et al.  A viscoelastic fluid model for describing the mechanics of a coarse ligated plasma clot , 2006 .

[14]  G. Karahalios Some possible effects of a catheter on the arterial wall. , 1990, Medical physics.

[15]  G Jayaraman,et al.  Estimation of increased flow resistance in a narrow catheterized artery--a theoretical model. , 1996, Journal of biomechanics.

[16]  D. C. Spanner,et al.  An introduction to biorheology , 1974 .

[17]  W. Brugge,et al.  EUS-guided portal vein catheterization and pressure measurement in an animal model: a pilot study of feasibility. , 2004, Gastrointestinal endoscopy.

[18]  P. O'kelly,et al.  A Prospective Comparison of Two Types of Tunneled Hemodialysis Catheters: The Ash Split Versus the PermCath , 2005, CardioVascular and Interventional Radiology.

[19]  G. Thurston Light transmission through blood in oscillatory flow. , 1990, Biorheology.

[20]  G. Thurston,et al.  THE KINETICS OF VISCOELASTIC CHANGES DUE TO BLOOD CLOT FORMATION , 1992 .

[21]  Prabir Daripa,et al.  A numerical study of pulsatile blood flow in an eccentric catheterized artery using a fast algorithm , 2002 .

[22]  G. Thurston,et al.  Viscoelasticity of human blood. , 1972, Biophysical journal.

[23]  G. W. Blair,et al.  An Equation for the Flow of Blood, Plasma and Serum through Glass Capillaries , 1959, Nature.

[24]  S. Charm,et al.  Viscometry of Human Blood for Shear Rates of 0-100,000 sec−1 , 1965, Nature.

[25]  P. Chaturani,et al.  Pulsatile flow of Casson's fluid through stenosed arteries with applications to blood flow. , 1986, Biorheology.

[26]  K. Mann,et al.  Complex-dependent inhibition of factor VIIa by antithrombin III and heparin. , 1993, The Journal of biological chemistry.

[27]  K. Mann,et al.  A model for the tissue factor pathway to thrombin. I. An empirical study. , 1994, The Journal of biological chemistry.

[28]  G. Jayaraman,et al.  Flow in catheterised curved artery , 1995, Medical and Biological Engineering and Computing.

[29]  Aaron L. Fogelson,et al.  Continuum models of platelet aggregation: formulation and mechanical properties , 1992 .

[30]  D. S. Sankar,et al.  A non-Newtonian fluid flow model for blood flow through a catheterized artery—Steady flow , 2007 .

[31]  G. Thurston Plasma release-cell layering theory for blood flow. , 1989, Biorheology.

[32]  G. Thurston Erythrocyte Rigidity as a Factor in Blood Rheology: Viscoelastic Dilatancy , 1979 .

[33]  E W Salzman,et al.  Pressure-flow relations of human blood in hollow fibers at low flow rates. , 1965, Journal of applied physiology.

[34]  A. Popel,et al.  A two-phase model for flow of blood in narrow tubes with increased effective viscosity near the wall. , 2001, Biorheology.

[35]  G. Jayaraman,et al.  Numerical study of flow in a constricted curved annulus: An application to flow in a catheterised artery , 2001 .

[36]  S. Trerotola,et al.  Measurement of portal blood and transjugular intrahepatic portosystemic shunt flow with use of a retrograde thermodilutional catheter. , 2004, Journal of vascular and interventional radiology : JVIR.

[37]  G. Bugliarello,et al.  Velocity distribution and other characteristics of steady and pulsatile blood flow in fine glass tubes. , 1970, Biorheology.

[38]  Aaron L Fogelson,et al.  Platelet-wall interactions in continuum models of platelet thrombosis: formulation and numerical solution. , 2004, Mathematical medicine and biology : a journal of the IMA.

[39]  M. Anand,et al.  A SHEAR-THINNING VISCOELASTIC FLUID MODEL FOR DESCRIBING THE FLOW OF BLOOD , 2004 .

[40]  G Jayaraman,et al.  Flow in a catheterized curved artery with stenosis. , 1999, Journal of biomechanics.

[41]  Prashanta Kumar Mandal,et al.  Unsteady Flow of a Two-Layer Blood Stream Past a Tapered Flexible Artery under Stenotic Conditions , 2004 .

[42]  D. A. MacDonald Pulsatile flow in a catheterised artery. , 1986, Journal of biomechanics.

[43]  K. Mann,et al.  The dynamics of thrombin formation. , 2003, Arteriosclerosis, thrombosis, and vascular biology.