: a software for reporting organ doses from CT for adult and pediatric patients

We investigated the possibility of reducing radiation dose to the breast tissue of pediatric females by using multiple tube voltages within a single CT examination. The peak kilovoltage (kVp) was adjusted when the x-ray beam was directly exposing the representative breast tissue of a 5-year-old, 10-yearold, and an adult female anthropomorphic phantom; this strategy was called kVp splitting and was emulated by using a different kVp over the anterior and posterior tube angles. Dose savings from kVp splitting were calculated relative to using a fixed kVp over all tube angles and the results indicated savings in all three phantoms when using 80 kVp over the posterior tube angles regardless of the anterior kVp. Monte Carlo (MC) simulations with and without kVp splitting were performed to estimate absorbed breast dose in voxelized models constructed from the CT images of pediatric female patients; 80 kVp was used over the posterior tube angles. The MC simulations revealed breast dose savings of between 9.8% and 33% from using kVp splitting compared to simulations using a fixed kVp protocol with the anterior technique. Before this strategy could be implemented clinically, the development of suitable image reconstruction algorithms and the image quality of scans with kVp splitting would need further study. (Some figures may appear in colour only in the online journal)

[1]  Willi A. Kalender,et al.  Reduction of dose to the female breast in thoracic CT: a comparison of standard-protocol, bismuth-shielded, partial and tube-current-modulated CT examinations , 2008, European Radiology.

[2]  Beverley Newman,et al.  Evaluation of a radiation dose reduction strategy for pediatric chest CT. , 2010, AJR. American journal of roentgenology.

[3]  James H Thrall,et al.  Multi-detector row CT: radiation dose characteristics. , 2003, Radiology.

[4]  H. Kauczor,et al.  Radiation dose reduction in chest CT: a review. , 2008, AJR. American journal of roentgenology.

[5]  Holger Greess,et al.  Dose reduction in CT by on-line tube current control: principles and validation on phantoms and cadavers , 1999, European Radiology.

[6]  Frank Bergner,et al.  Water calibration for CT scanners with tube voltage modulation. , 2010, Physics in medicine and biology.

[7]  J J DeMarco,et al.  A Monte Carlo based method to estimate radiation dose from multidetector CT (MDCT): cylindrical and anthropomorphic phantoms. , 2005, Physics in medicine and biology.

[8]  P. Schonken,et al.  Health effects of exposure to low levels of ionizing radiation , 1991 .

[9]  Bernhard Schmidt,et al.  Radiation dose and image quality in pediatric CT: effect of technical factors and phantom size and shape. , 2004, Radiology.

[10]  J J DeMarco,et al.  Estimating radiation doses from multidetector CT using Monte Carlo simulations: effects of different size voxelized patient models on magnitudes of organ and effective dose , 2007, Physics in medicine and biology.

[11]  Lee W Goldman,et al.  Principles of CT: Radiation Dose and Image Quality* , 2007, Journal of Nuclear Medicine Technology.

[12]  Cynthia H McCollough,et al.  A method to generate equivalent energy spectra and filtration models based on measurement for multidetector CT Monte Carlo dosimetry simulations. , 2009, Medical physics.

[13]  C. Engeler,et al.  Christensen's Physics of Diagnostic Radiology. 4th ed , 1991 .