Noninvasive Measurement of the Human Brachial Artery Pressure–Area Relation in Collapse and Hypertension

AbstractA noninvasive method to obtain pressure–lumen area (P-A) measurements of the human brachial artery is introduced. The data obtained from this method are analyzed using a mathematical model of the relationship between vessel pressure and lumen area including vessel collapse and hypertension. An occlusive arm cuff is applied to the brachial artery of ten normal subjects. The cuff compliance is determined continuously by means of a known external volume calibration pump. This permits the computation of the P-A curve of the brachial artery under the cuff. A model is applied to analyze the P-A relation of each subject. The results show that the lumen area varies considerably between subjects. The in vivo resting P-A curve of the brachial artery possesses features similar to that of in vitro measurements. A primary difference is that the buckling pressure is higher in vivo, presumably due to axial tension, as opposed to in vitro where it is near zero or negative. It is found that hypertension causes a shift in the P-A curve towards larger lumen areas. Also, the compliance–pressure curve is shown to shift towards higher transmural pressures. Increased lumen area provides an adaptive mechanism by which compliance can be maintained constant in the face of elevated blood pressure, in spite of diminished distensibility. © 1998 Biomedical Engineering Society. PAC98: 8745Hw, 8710+e

[1]  A. Rovick,et al.  Influence of vascular smooth muscle on contractile mechanics and elasticity of arteries. , 1969, The American journal of physiology.

[2]  M. A. Greene,et al.  Distensibility of Arteries in Human Hypertension , 1966, Proceedings of the Society for Experimental Biology and Medicine. Society for Experimental Biology and Medicine.

[3]  J K Raines,et al.  A noninvasive pressure-pulse recorder: development and rationale. , 1973, Medical instrumentation.

[4]  M. Ramsey Noninvasive automatic determination of mean arterial pressure , 2006, Medical and Biological Engineering and Computing.

[5]  Alain Simon,et al.  Mechanical Pressure Versus Intrinsic Effects of Hypertension on Large Arteries in Humans , 1991, Hypertension.

[6]  Noninvasive determination of elastic properties and diameter of human limb arteries , 1983, Pflügers Archiv.

[7]  G. Drzewiecki,et al.  Transmural pressure-area relation for veins and arteries , 1988, Proceedings of the 1988 Fourteenth Annual Northeast Bioengineering Conference.

[8]  A. Coats,et al.  Validation of ambulatory monitors in special populations. , 1992, American Journal of Hypertension.

[9]  Y. Tardy,et al.  Conduit artery compliance and distensibility are not necessarily reduced in hypertension. , 1992, Hypertension.

[10]  A. Simon,et al.  Evidence for in vivo carotid and femoral wall thickening in human hypertension. Groupe de Prévention Cardio-vasculaire en Médecine du Travail. , 1993, Hypertension.

[11]  S Field,et al.  Vessel growth and collapsible pressure-area relationship. , 1997, The American journal of physiology.

[12]  H. Shimazu,et al.  Electric impedance cuff for the indirect measurement of blood pressure and volume elastic modulus in human limb and finger arteries , 2006, Medical and Biological Engineering and Computing.

[13]  G. Drzewiecki,et al.  A nonlinear model of the arterial system incorporating a pressure-dependent compliance , 1990, IEEE Transactions on Biomedical Engineering.

[14]  J. Levenson,et al.  Estimation of forearm arterial compliance in normal and hypertensive men from simultaneous pressure and flow measurements in the brachial artery, using a pulsed Doppler device and a first-order arterial model during diastole. , 1983, Cardiovascular research.

[15]  A. Bank,et al.  Contribution of collagen, elastin, and smooth muscle to in vivo human brachial artery wall stress and elastic modulus. , 1996, Circulation.

[16]  C. Roy,et al.  The Elastic Properties of the Arterial Wall , 1881, The Journal of physiology.

[17]  G. Drzewiecki,et al.  Theory of the oscillometric maximum and the systolic and diastolic detection ratios , 2006, Annals of Biomedical Engineering.

[18]  M. O'Rourke,et al.  Arterial dilation and reduced wave reflection. Benefit of dilevalol in hypertension. , 1989, Hypertension.

[19]  S. I. Rubinow,et al.  Post Buckling Behavior of Elastic Tubes and Rings with Opposite Sides in Contact , 1972 .

[20]  Studies on innocent praecordial vibratory murmurs in children. I. Systolic time intervals and pulse wave transmission times in normal children. , 1973, British heart journal.

[21]  L. Geddes,et al.  Characterization of the oscillometric method for measuring indirect blood pressure , 2006, Annals of Biomedical Engineering.

[22]  J.G. Webster,et al.  Noninvasive measurement of compliance of human leg arteries , 1991, IEEE Transactions on Biomedical Engineering.

[23]  Y. Tardy,et al.  Evaluation of Arterial Compliance‐Pressure Curves Effect of Antihypertensive Drugs , 1991, Hypertension.

[24]  G. Drzewiecki,et al.  Mechanics of the occlusive arm cuff and its application as a volume sensor , 1993, IEEE Transactions on Biomedical Engineering.

[25]  A. Noordergraaf,et al.  Cross-sectional shape of collapsible tubes. , 1972, Biophysical journal.

[26]  A I Katz,et al.  An integrated approach to the study of the venous system with steps toward a detailed model of the dynamics of venous return to the right heart. , 1969, IEEE transactions on bio-medical engineering.

[27]  A. Noordergraaf Circulatory System Dynamics , 1978 .

[28]  A. Noordergraaf,et al.  The Krotkoff sound , 1989, Annals of Biomedical Engineering.