A Modified Level-Shifted PWM Strategy for Fault-Tolerant Cascaded Multilevel Inverters With Improved Power Distribution

To increase the fault tolerance for cascaded H-bridge multilevel inverters (CHMIs) based on level-shifted pulse width modulation (LS-PWM), a modified LS-PWM method is proposed for the inverters operating under faulty conditions. To cover both open- and short-device fault cases, two types of switching scheme are included in this PWM method. With this PWM method, the neutral shift can be applied as fault-tolerant control for CHMIs based on LS-PWM. Finally, three-phase-balanced line-to-line voltages and currents with minimum harmonic distortion are produced for the inverter with disabled power cells. In addition, this LS-PWM method has the capability to improve power distribution among the H-bridge power cells under the faulty conditions. Simulation and experimental results show that the proposed PWM method performs satisfactorily to achieve fault tolerance.

[1]  Leon M. Tolbert,et al.  Fault Diagnosis and Reconfiguration for Multilevel Inverter Drive Using AI-Based Techniques , 2007, IEEE Transactions on Industrial Electronics.

[2]  Mariusz Malinowski,et al.  A Survey on Cascaded Multilevel Inverters , 2010, IEEE Transactions on Industrial Electronics.

[3]  J. Pontt,et al.  Operation of a medium-voltage drive under faulty conditions , 2004, The 4th International Power Electronics and Motion Control Conference, 2004. IPEMC 2004..

[4]  Bin Wu,et al.  High-Power Converters and ac Drives: Wu/High-Power Converters and ac Drives , 2006 .

[5]  Sheldon S. Williamson,et al.  Design and Development of an Efficient Multilevel DC/AC Traction Inverter for Railway Transportation Electrification , 2016, IEEE Transactions on Power Electronics.

[6]  L. Terens,et al.  Reliability, availability and maintainability (RAM) of high power variable speed drive systems (VSDS) , 1998, Record of Conference Papers. IEEE Industry Applications Society 45th Annual Petroleum and Chemical Industry Conference (Cat. No.98CH36234).

[7]  Ranganath Muthu,et al.  Comparison of Cascaded H-Bridge, Neutral Point Clamped and Flying Capacitor multilevel inverters using multicarrier PWM , 2011, 2011 Annual IEEE India Conference.

[8]  June-Seok Lee,et al.  Open-Switch Fault Tolerance Control for a Three-Level NPC/T-Type Rectifier in Wind Turbine Systems , 2015, IEEE Transactions on Industrial Electronics.

[9]  Ahmed Hammoda,et al.  Evaluation of modulation techniques for 5-level inverter based on multicarrier level shift PWM , 2014, MELECON 2014 - 2014 17th IEEE Mediterranean Electrotechnical Conference.

[10]  Pablo Lezana,et al.  Fault Detection on Multicell Converter Based on Output Voltage Frequency Analysis , 2009, IECON 2006 - 32nd Annual Conference on IEEE Industrial Electronics.

[11]  Bin Wu,et al.  Multilevel Voltage-Source-Converter Topologies for Industrial Medium-Voltage Drives , 2007, IEEE Transactions on Industrial Electronics.

[12]  Francesc Guinjoan,et al.  Energy-Balance Control of PV Cascaded Multilevel Grid-Connected Inverters Under Level-Shifted and Phase-Shifted PWMs , 2013, IEEE Transactions on Industrial Electronics.

[13]  Bin Wu,et al.  Control method for cascaded H-bridge multilevel inverter with faulty power cells , 2003, Eighteenth Annual IEEE Applied Power Electronics Conference and Exposition, 2003. APEC '03..

[14]  Ji-Yoon Yoo,et al.  Unbalanced three-phase control using offset-voltage for H-bridge multilevel inverter with faulty power cells , 2008, 2008 IEEE Power Electronics Specialists Conference.

[15]  Sergio Busquets-Monge,et al.  Analysis of the Fault-Tolerance Capacity of the Multilevel Active-Clamped Converter , 2013, IEEE Transactions on Industrial Electronics.

[16]  Domingo Biel Solé,et al.  Energy-balance control of PV cascaded multilevel grid-connected inverters for phase-shifted and level-shifted pulse-width modulations , 2012 .

[17]  J. Nazarzadeh,et al.  Cascaded multilevel inverters fault control , 2011, International Aegean Conference on Electrical Machines and Power Electronics and Electromotion, Joint Conference.

[18]  P. Hammond,et al.  Neutral shift [five years of continuous operation with adjustable frequency drives] , 2003 .

[19]  Bin Wu,et al.  High-Power Converters and AC Drives , 2006 .

[20]  Hirofumi Akagi,et al.  Fault-Tolerant Operation of a Battery-Energy-Storage System Based on a Multilevel Cascade PWM Converter With Star Configuration , 2010, IEEE Transactions on Power Electronics.

[21]  June-Seok Lee,et al.  A detection method for an open-switch fault in cascaded H-bridge multilevel inverters , 2014, 2014 IEEE Energy Conversion Congress and Exposition (ECCE).

[22]  June-Seok Lee,et al.  Cascaded H-bridge multilevel inverter for increasing output voltage levels , 2014, 2014 IEEE Conference on Energy Conversion (CENCON).

[23]  Lei Hu,et al.  Reconfiguration of Carrier-Based Modulation Strategy for Fault Tolerant Multilevel Inverters , 2007, IEEE Transactions on Power Electronics.

[24]  Alex Q. Huang,et al.  Fault-Tolerant Design and Control Strategy for Cascaded H-Bridge Multilevel Converter-Based STATCOM , 2010, IEEE Transactions on Industrial Electronics.