Liquid-crystal adaptive optics based on feedback interferometry for high-resolution retinal imaging.

A novel, to our knowledge, adaptive optical imaging system for high-resolution retinal imaging is described. The system is based on a feedback interferometer, in which two-dimensional output fringe intensity from a Mach-Zehnder interferometer with large radial shear is fed back, with the help of a video projector connected with a CCD camera, to an optically addressed phase-only liquid-crystal spatial light modulator. Experiments to verify the system performance have been conducted by use of an artificial eye consisting of a lens, an aberration plate, and a resolution test target. We observed that an image of the test target (mimicking a retina) blurred by the aberration plate (mimicking ocular aberrations) was successfully restored immediately after our adaptive optics system was activated.

[1]  P Artal,et al.  Simultaneous measurement of two-point-spread functions at different locations across the human fovea. , 1992, Applied optics.

[2]  Junzhong Liang,et al.  Aberrations and retinal image quality of the normal human eye. , 1997, Journal of the Optical Society of America. A, Optics, image science, and vision.

[3]  D. O'Neill 22 – The normal fundus , 1994 .

[4]  Tomohiro Shirai,et al.  Adaptive restoration of a partially coherent blurred image using an all-optical feedback interferometer with a liquid-crystal device. , 2002, Journal of the Optical Society of America. A, Optics, image science, and vision.

[5]  P Artal,et al.  High-resolution retinal images obtained by deconvolution from wave-front sensing. , 2000, Optics letters.

[6]  F. Delori,et al.  Monochromatic ophthalmoscopy and fundus photography. II. The pathological fundus. , 1979, Archives of ophthalmology.

[7]  R. Weinreb,et al.  Active optical depth resolution improvement of the laser tomographic scanner. , 1989, Applied optics.

[8]  G. Love,et al.  Liquid crystal adaptive optics , 2002, The 15th Annual Meeting of the IEEE Lasers and Electro-Optics Society.

[9]  G. M. Morris,et al.  Images of cone photoreceptors in the living human eye , 1996, Vision Research.

[10]  LARRY N. THIBOS,et al.  Use of Liquid-Crystal Adaptive-Optics to Alter the Refractive State of the Eye , 1997, Optometry and vision science : official publication of the American Academy of Optometry.

[11]  P Artal,et al.  High-resolution imaging of the living human fovea: measurement of the intercenter cone distance by speckle interferometry. , 1989, Optics letters.

[12]  H. W. Babcock,et al.  Adaptive Optics Revisited , 1990, Science.

[13]  Y Fainman,et al.  Adaptive control of a micromachined continuous-membrane deformable mirror for aberration compensation. , 1999, Applied optics.

[14]  D. Van Norren,et al.  Intensity and polarization of light scattered at small angles from the human fovea , 1986, Vision Research.

[15]  P Artal,et al.  Coherent imaging of the cone mosaic in the living human eye. , 1996, Journal of the Optical Society of America. A, Optics, image science, and vision.

[16]  Thomas H. Barnes,et al.  High resolution adaptive optics using an Interference Phase Loop , 1996 .

[17]  Austin Roorda,et al.  Wavefront Sensing And Compensation For The Human Eye , 1999 .

[18]  David Williams,et al.  The arrangement of the three cone classes in the living human eye , 1999, Nature.

[19]  P Artal,et al.  Correction of the aberrations in the human eye with a liquid-crystal spatial light modulator: limits to performance. , 1998, Journal of the Optical Society of America. A, Optics, image science, and vision.

[20]  P Artal,et al.  Dynamics of the eye's wave aberration. , 2001, Journal of the Optical Society of America. A, Optics, image science, and vision.

[21]  T H Barnes,et al.  Adaptive wave-front correction by means of all-optical feedback interferometry. , 2000, Optics letters.

[22]  R C Pruett,et al.  Monochromatic ophthalmoscopy and fundus photography. The normal fundus. , 1977, Archives of ophthalmology.

[23]  D R Williams,et al.  Supernormal vision and high-resolution retinal imaging through adaptive optics. , 1997, Journal of the Optical Society of America. A, Optics, image science, and vision.

[24]  T. Shirai,et al.  Real-time restoration of a blurred image with a liquid-crystal adaptive-optics system based on all-optical feedback interferometry , 2001 .

[25]  I Iglesias,et al.  Closed-loop adaptive optics in the human eye. , 2001, Optics letters.

[26]  D R Williams,et al.  Effect of rotation and translation on the expected benefit of an ideal method to correct the eye's higher-order aberrations. , 2001, Journal of the Optical Society of America. A, Optics, image science, and vision.

[27]  D. Williams,et al.  Monochromatic aberrations of the human eye in a large population. , 2001, Journal of the Optical Society of America. A, Optics, image science, and vision.

[28]  Naohisa Mukohzaka,et al.  High Efficiency Electrically-Addressable Phase-Only Spatial Light Modulator , 1999 .

[30]  David H. Sliney,et al.  Safety standards and measurement techniques for high intensity light sources , 1980, Vision Research.

[31]  R Navarro,et al.  Phase plates for wave-aberration compensation in the human eye. , 2000, Optics letters.

[32]  B. Singer,et al.  Improvement in retinal image quality with dynamic correction of the eye's aberrations. , 2001, Optics express.

[33]  J. Gorrand Reflection characteristics of the human fovea assessed by reflecto‐modulometry , 1989, Ophthalmic & physiological optics : the journal of the British College of Ophthalmic Opticians.