Non-laser percutaneous extraction of pacemaker and defibrillation leads: a decade of progress

Aims Non-laser-based methods are safe in lead extraction but in the past have been less effective than laser methods. In the past decade, new equipment has been introduced including the Evolution® Mechanical Dilator Sheath and the Evolution® RL. We sought to determine the impact of new equipment on outcome in mechanical lead extraction. Methods and results We considered 288 consecutive patients (age 66 ± 18 years) who underwent transvenous lead extraction (TLE) of 522 leads in the decade to the end of 2014. Three groups were identified: Group 1 (pre-Evolution® period, 76 patients, 133 leads), Group 2 (original Evolution® period, 115 patients, 221 leads), and Group 3 (Evolution® RL period, 97 patients, 168 leads). The age of leads was significantly greater in Groups 2 and 3 (6.2 ± 4.4 and 6.1 ± 5.4 years vs.4.7 ± 4.5, P < 0.05) as was the proportion of implantable cardioverter defibrillator leads (27.2 and 28.9 vs. 14.3%, P < 0.05). The groups were similar in the number of leads extracted per patient. Despite the increasing complexity of the systems extracted, complete extraction was achieved in a progressively greater proportion of leads (88.0% in Group 1, 95.5% in Group 2, and 97.6% in Group 3, P < 0.05), and procedure duration was similar. The proportion of leads for which femoral access was required was greater in Group 3 (11%, 18/164) compared with Group 2 (3%, 7/211), P = 0.006. The only major complications were a post-procedure subacute tamponade in Group 1 and an oesophageal injury related to transoesophageal echocardiography in Group 3. Conclusion With current equipment, mechanical extraction provides a good combination of efficacy and safety.

[1]  C. Ervin,et al.  Lead extraction in the contemporary setting: the LExICon study: an observational retrospective study of consecutive laser lead extractions. , 2010, Journal of the American College of Cardiology.

[2]  Michael P. Brunner,et al.  Clinical predictors of adverse patient outcomes in an experience of more than 5000 chronic endovascular pacemaker and defibrillator lead extractions. , 2014, Heart rhythm.

[3]  A. Oto,et al.  Evolution in Transvenous Extraction of Pacemaker and Implantable Cardioverter Defibrillator Leads Using a Mechanical Dilator Sheath , 2012, Pacing and clinical electrophysiology : PACE.

[4]  M. Niebauer,et al.  Nonthoracotomy Implantable Defibrillator Lead Extraction: , 2003, Pacing and clinical electrophysiology : PACE.

[5]  J. Deharo,et al.  Pathways for training and accreditation for transvenous lead extraction: a European Heart Rhythm Association position paper. , 2012, Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology.

[6]  V. Falk,et al.  Transvenous lead extractions: comparison of laser vs. mechanical approach. , 2013, Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology.

[7]  M. Bongiorni,et al.  Safety and efficacy of internal transjugular approach for transvenous extraction of implantable cardioverter defibrillator leads. , 2014, Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology.

[8]  A. Oto,et al.  Percutaneous extraction of cardiac pacemaker and implantable cardioverter defibrillator leads with evolution mechanical dilator sheath: a single-centre experience. , 2011, Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology.

[9]  V. Falk,et al.  Clinical performance of a new bidirectional rotational mechanical lead extraction sheath. , 2016, Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology.

[10]  G. M. Chaudhry,et al.  Multicenter experience with extraction of the Sprint Fidelis implantable cardioverter-defibrillator lead. , 2011, Journal of the American College of Cardiology.

[11]  K. Aytemir,et al.  Initial experience with the TightRail™ Rotating Mechanical Dilator Sheath for transvenous lead extraction. , 2016, Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology.

[12]  David O. Martin,et al.  Initial experience with the Evolution mechanical dilator sheath for lead extraction: safety and efficacy. , 2010, Heart rhythm.

[13]  Giuseppe Boriani,et al.  From lead management to implanted patient management: systematic review and meta-analysis of the last 15 years of experience in lead extraction , 2013, Expert review of medical devices.

[14]  V. Falk,et al.  Compression coil provides increased lead control in extraction procedures. , 2015, Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology.

[15]  Robert G. Hauser,et al.  Deaths and cardiovascular injuries due to device-assisted implantable cardioverter–defibrillator and pacemaker lead extraction , 2009, Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology.

[16]  Maria Grazia Bongiorni,et al.  Transvenous lead extraction: Heart Rhythm Society expert consensus on facilities, training, indications, and patient management: this document was endorsed by the American Heart Association (AHA). , 2009, Heart rhythm.

[17]  D L Hayes,et al.  Pacemaker lead extraction with the laser sheath: results of the pacing lead extraction with the excimer sheath (PLEXES) trial. , 1999, Journal of the American College of Cardiology.