Optimizing multiphoton fluorescence microscopy light collection from living tissue by noncontact total emission detection (epiTED)

A benefit of multiphoton fluorescence microscopy is the inherent optical sectioning that occurs during excitation at the diffraction‐limited spot. The scanned collection of fluorescence emission is incoherent; that is, no real image needs to be formed on the detector plane. The nearly isotropic emission of fluorescence excited at the focal spot allows for new detection schemes that efficiently funnel all attainable photons to detector(s). We previously showed [Combs, C.A., et al. (2007) Optimization of multiphoton excitation microscopy by total emission detection using a parabolic light reflector. J. Microsc. 228, 330–337] that parabolic mirrors and condensers could be combined to collect the totality of solid angle around the excitation spot for tissue blocks, leading to ∼8‐fold signal gain. Using a similar approach, we have developed an in vivo total emission detection (epiTED) instrument modified to make noncontact images from outside of living tissue. Simulations suggest that a ∼4‐fold enhancement may be possible (much larger with lower NA objectives than the 0.95 NA used here) with this approach, depending on objective characteristics, imaging depth and the characteristics of the sample being imaged. In our initial prototype, 2‐fold improvements were demonstrated in the mouse brain and skeletal muscle as well as the rat kidney, using a variety of fluorophores and no compromise of spatial resolution. These results show this epiTED prototype effectively doubles emission signal in vivo; thus, it will maintain the image signal‐to‐noise ratio at two times the scan rate or enable full scan rate at approximately 30% reduced laser power (to minimize photo‐damage).

[1]  W. Denk,et al.  Deep tissue two-photon microscopy , 2005, Nature Methods.

[2]  Fritjof Helmchen,et al.  Enhanced fluorescence signal in nonlinear microscopy through supplementary fiber-optic light collection. , 2009, Optics express.

[3]  K. Svoboda,et al.  Principles of Two-Photon Excitation Microscopy and Its Applications to Neuroscience , 2006, Neuron.

[4]  L Leybaert,et al.  A simple and practical method to acquire geometrically correct images with resonant scanning‐based line scanning in a custom‐built video‐rate laser scanning microscope , 2005, Journal of microscopy.

[5]  Thomas M Bartol,et al.  Hybrid reflecting objectives for functional multiphoton microscopy in turbid media. , 2006, Optics letters.

[6]  P. So,et al.  Handbook of Biomedical Nonlinear Optical Microscopy , 2009 .

[7]  H. J. van Staveren,et al.  Light scattering in Intralipid-10% in the wavelength range of 400-1100 nm. , 1991, Applied optics.

[8]  Michael L. Dustin,et al.  MYELOMONOCYTIC CELL RECRUITMENT CAUSES FATAL CNS VASCULAR INJURY DURING ACUTE VIRAL MENINGITIS , 2008, Nature.

[9]  G. Patterson,et al.  Photobleaching in two-photon excitation microscopy. , 2000, Biophysical journal.

[10]  Andrew K. Dunn,et al.  Two-Photon Microscopy in Highly Scattering Tissue , 2001 .

[11]  W. Denk,et al.  Two-photon laser scanning fluorescence microscopy. , 1990, Science.

[12]  W. Webb,et al.  Nonlinear magic: multiphoton microscopy in the biosciences , 2003, Nature Biotechnology.

[13]  Jerome Mertz,et al.  Nonlinear microscopy: new techniques and applications , 2004, Current Opinion in Neurobiology.

[14]  Alberto Diaspro,et al.  Biomedical Engineering Online Multi-photon Excitation Microscopy , 2006 .

[15]  Olivier D. Faugeras,et al.  Flows of diffeomorphisms for multimodal image registration , 2002, Proceedings IEEE International Symposium on Biomedical Imaging.

[16]  Olivier D. Faugeras,et al.  Variational Methods for Multimodal Image Matching , 2002, International Journal of Computer Vision.

[17]  Mark J. Miller,et al.  Chapter 16. Two-photon microscopy and multidimensional analysis of cell dynamics. , 2009, Methods in enzymology.

[18]  C. Chefd'Hotel,et al.  Short Communication: Subcellular Motion Compensation for Minimally Invasive Microscopy, In Vivo: Evidence for Oxygen Gradients in Resting Muscle , 2010, Circulation research.

[19]  Leslie M Loew,et al.  Second-harmonic imaging microscopy for visualizing biomolecular arrays in cells, tissues and organisms , 2003, Nature Biotechnology.

[20]  W. Gan,et al.  ATP mediates rapid microglial response to local brain injury in vivo , 2005, Nature Neuroscience.

[21]  Jay R Knutson,et al.  Optimization of multiphoton excitation microscopy by total emission detection using a parabolic light reflector , 2007, Journal of microscopy.