Study of Low Voltage Ride through in Photovoltaic Grid-Tied Inverter Based on Unsymmetrical Grid Voltage Fall

In this paper, 10KW three-phase three-level photovoltaic grid-tied inverter is applied as hardware platform. Considering the insufficiency of PV arrays power output and low overall efficiency due to grid voltage falls asymmetrically, P-R current controller is used to provide unsymmetrical positive and negative sequence current to the grid so that low voltage ride through (LVPT) in photovoltaic inverter can be achieved. Through the implement of experiments, it is well proved that the requirement of LVPT when the grid voltage falls asymmetrically can be met by applying the solution proposed in this paper.