Transfer of metallic debris from the metal surface of an acetabular cup to artificial femoral heads by scraping: comparison between alumina and cobalt-chrome heads.

We aimed to investigate the transfer of metal to both ceramic (alumina) and metal (cobalt-chrome) heads that were scraped by a titanium alloy surface under different load conditions. The ceramic and metal heads for total hip arthroplasties were scraped by an acetabular metal shell under various loads using a creep tester. Microstructural changes in the scraped area were visualized with a scanning electron microscope, and chemical element changes were assessed using an energy dispersive X-ray spectrometry. Changes in the roughness of the scraped surface were evaluated by a three-dimensional surface profiling system. Metal transfer to the ceramic and metal heads began to be detectable at a 10 kg load, which could be exerted by one-handed force. The surface roughness values significantly increased with increasing test loads in both heads. When the contact force increased, scratching of the head surface occurred in addition to the transfer of metal. The results documented that metallic debris was transferred from the titanium alloy acetabular shell to both ceramic and metal heads by minor scraping. This study suggests that the greatest possible effort should be made to protect femoral heads, regardless of material, from contact with metallic surfaces during total hip arthroplasty.

[1]  B. Cho,et al.  Vascularized compared with nonvascularized fibular grafts for large osteonecrotic lesions of the femoral head. , 2005, The Journal of bone and joint surgery. American volume.

[2]  C. Hardaker,et al.  Surface roughness of ceramic femoral heads after in vivo transfer of metal: correlation to polyethylene wear. , 2005, The Journal of bone and joint surgery. American volume.

[3]  C. Chung,et al.  Valgus femoral osteotomy for hinge abduction in Perthes' disease. Decision-making and outcomes. , 2004, The Journal of bone and joint surgery. British volume.

[4]  Jove Graham,et al.  Wear and surface cracking in early retrieved highly cross-linked polyethylene acetabular liners. , 2004, The Journal of bone and joint surgery. American volume.

[5]  Young-Min Kim,et al.  Damage of an alumina-on-alumina bearing surface from a difficult reduction of a total hip arthroplasty. A report of three cases. , 2004, The Journal of bone and joint surgery. American volume.

[6]  C. Mclean,et al.  Delayed fracture of the ceramic femoral head after trauma. , 2002, The Journal of arthroplasty.

[7]  N. Sugano,et al.  Analysis of Survivorship After Total Hip Arthroplasty Using a Ceramic Head , 2001, Clinical orthopaedics and related research.

[8]  P. Campbell,et al.  Osteolysis in a Cementless, Second Generation Metal-on-Metal Hip Replacement , 2001, Clinical orthopaedics and related research.

[9]  M. Hasegawa,et al.  Poor outcome of 44 cemented total hip arthroplasties with alumina ceramic heads: Clinical evaluation and retrieval analysis after 10-16 years , 2001, Acta orthopaedica Scandinavica.

[10]  B. K. Vaughn,et al.  Early osteolysis following total hip arthroplasty with use of a Hylamer liner in combination with a modular ceramic femoral head. A case report. , 1999, The Journal of bone and joint surgery. American volume.

[11]  W. Maloney,et al.  Osteolysis in Association with a Total Hip Arthroplasty with Ceramic Bearing Surfaces* , 1998, The Journal of bone and joint surgery. American volume.

[12]  E. Vresilovic,et al.  Drain entrapment and titanium to ceramic head deposition: two unique complications following closed reduction of a dislocated total hip arthroplasty. , 1998, The Journal of arthroplasty.

[13]  J Fisher,et al.  Quantification of third-body damage and its effect on UHMWPE wear with different types of femoral head. , 1998, The Journal of bone and joint surgery. British volume.

[14]  P. Z. Wirganowicz,et al.  Massive osteolysis after ceramic on ceramic total hip arthroplasty. A case report. , 1997, Clinical orthopaedics and related research.

[15]  E. A. Reeves,et al.  The Influence of Scratches to Metallic Counterfaces on the Wear of Ultra-High Molecular Weight Polyethylene , 1995, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.

[16]  K. Takaoka,et al.  Polyethylene sockets and alumina ceramic heads in cemented total hip arthroplasty. A ten-year study. , 1995, The Journal of bone and joint surgery. British volume.

[17]  J Kärrholm,et al.  Osteolysis after ceramic-on-ceramic hip arthroplasty. A case report. , 1991, Acta orthopaedica Scandinavica.

[18]  P. D. Di Cesare,et al.  Catastrophic failure of the acetabular component in a ceramic-polyethylene bearing total hip arthroplasty. , 1998, The Journal of arthroplasty.