Clinical evaluation of time-resolved spectroscopy by measuring cerebral hemodynamics during cardiopulmonary bypass surgery.

We developed a three-wavelength time-resolved spectroscopy (TRS) system, which allows quantitative measurement of hemodynamics within relatively large living tissue. We clinically evaluated this TRS system by monitoring cerebral circulation during cardiopulmonary bypass surgery. Oxyhemoglobin, deoxyhemoglobin, total hemoglobin and oxygen saturation (SO(2)) were determined by TRS on the left forehead attached with an optode spacing of 4 cm. We also simultaneously monitored jugular venous oxygen saturation (SjvO(2)) and arterial blood hematocrit (Hct) using conventional methods. The validity and usefulness of the TRS system were assessed by comparing parameters obtained with the TRS and conventional methods. Although the changes in SO(2) were lower than those in SjvO(2), SO(2) obtained by TRS paralleled the fluctuations in SjvO(2), and a good correlation between these values was observed. The only exceptions occurred during the perfusion period. Moreover, there was a good correlation between tHb and Hct values (r(2)=0.63). We concluded that time-resolved spectroscopy reflected the conditions of cerebral hemodynamics of patients during surgical operations.

[1]  B Barzilai,et al.  Adverse cerebral outcomes after coronary bypass surgery. , 1997, The New England journal of medicine.

[2]  B Chance,et al.  Quantitative Measurement of Optical Parameters in the Breast Using Time-Resolved Spectroscopy: Phantom and Preliminary In Vivo Results , 1994, Investigative radiology.

[3]  Keiji Shimizu,et al.  Near-infrared time-resolved spectroscopy system for tissue oxygenation monitor , 1999, Photonics West - Biomedical Optics.

[4]  K. Kitaguchi,et al.  The Association of High Jugular Bulb Venous Oxygen Saturation with Cognitive Decline After Hypothermic Cardiopulmonary Bypass , 2001, Anesthesia and analgesia.

[5]  J. Berridge,et al.  Does Hypothermia Prevent Cerebral Ischaemia during Cardiopulmonary Bypass? , 1999, Cardiovascular surgery.

[6]  Akira Matsunaga,et al.  Continuous, noninvasive measurement of cytochrome oxidase in cerebral cortex by near-infrared spectrophotometry during aortic arch surgery , 1996, Journal of Anesthesia.

[7]  Takashi Kusaka,et al.  Developmental Changes of Optical Properties in Neonates Determined by Near-Infrared Time-Resolved Spectroscopy , 2005, Pediatric Research.

[8]  Yutaka Tsuchiya,et al.  Simple Subtraction Method for Determining the Mean Path Length Traveled by Photons in Turbid Media , 1998 .

[9]  de Vries Jw,et al.  Neuromonitoring in defibrillation threshold testing. A comparison between EEG, near-infrared spectroscopy and jugular bulb oximetry. , 1997 .

[10]  Britton Chance,et al.  Time-resolved spectroscopy and imaging , 1995, Photonics West.

[11]  D. Mark,et al.  Longitudinal assessment of neurocognitive function after coronary-artery bypass surgery. , 2001, New England Journal of Medicine.

[12]  Mark F. Newman,et al.  Longitudinal assessment of neurocognitive function after coronary-artery bypass surgery. , 2001 .

[13]  Preliminary evaluation of a prototype spatially resolved spectrometer. , 1998, Acta neurochirurgica. Supplement.

[14]  Yutaka Tsuchiya,et al.  Calculation of Photon Path Distribution Based on Photon Behavior Analysis in a Scattering Medium , 2003 .

[15]  Yoko Hoshi,et al.  Intraoperative monitoring of depth-dependent hemoglobin concentration changes during carotid endarterectomy by time-resolved spectroscopy. , 2007, Applied optics.

[16]  M. Tamura,et al.  Quantitation of absolute concentration change in scattering media by the time-resolved microscopic Beer-Lambert law. , 1994, Advances in experimental medicine and biology.

[17]  S. Nicolson,et al.  Arterial and Venous Contributions to Near-infrared Cerebral Oximetry , 2000, Anesthesiology.

[18]  F. Kunimoto,et al.  Effects of hypothermic and normothermic cardiopulmonary bypass on brain oxygenation. , 1999, The Annals of thoracic surgery.

[19]  C. Fraser,et al.  A noninvasive estimation of mixed venous oxygen saturation using near‐infrared spectroscopy by cerebral oximetry in pediatric cardiac surgery patients , 2005, Paediatric anaesthesia.

[20]  M. Tamura,et al.  A simple and novel algorithm for time-resolved multiwavelength oximetry. , 1996, Physics in medicine and biology.

[21]  Yutaka Tsuchiya,et al.  Frequency Domain Analysis of Photon Migration Based on the Microscopic Beer-Lambert Law , 1996 .

[22]  Gerhard H. Visser,et al.  Neuromonitoring in defibrillation threshold testing. A comparison between EEG, near-infrared spectroscopy and jugular bulb oximetry. , 2004, Journal of Clinical Monitoring.

[23]  A. Sorensen,et al.  Improved sensitivity to cerebral hemodynamics during brain activation with a time-gated optical system: analytical model and experimental validation. , 2005, Journal of biomedical optics.

[24]  B. Wilson,et al.  Frequency-domain reflectance for the determination of the scattering and absorption properties of tissue. , 1991, Applied optics.

[25]  S Nioka,et al.  Time-resolved spectroscopy of hemoglobin and myoglobin in resting and ischemic muscle. , 1988, Analytical biochemistry.

[26]  Mitsuharu Miwa,et al.  Tissue spectroscopy with a newly developed phase modulation system based on the microscopic Beer-Lambert law , 2001, SPIE BiOS.

[27]  Y. Shingu,et al.  Real-time cerebral monitoring using multichannel near-infrared spectroscopy in total arch replacement. , 2003, The Japanese journal of thoracic and cardiovascular surgery : official publication of the Japanese Association for Thoracic Surgery = Nihon Kyobu Geka Gakkai zasshi.

[28]  Sergio Fantini,et al.  Semi-infinite-geometry boundary problem for light migration in highly scattering media: a frequency-domain study in the diffusion approximation , 1994 .

[29]  E. Ohmae,et al.  Continuous measurement of oxy- and deoxyhemoglobin of piglet brain by time-resolved spectroscopy , 1998 .

[30]  P. Poulet,et al.  Detection of cortical activation with time-resolved diffuse optical methods. , 2005, Applied optics.

[31]  E Gratton,et al.  Propagation of photon-density waves in strongly scattering media containing an absorbing semi-infinite plane bounded by a straight edge. , 1993, Journal of the Optical Society of America. A, Optics and image science.

[32]  D. Boas,et al.  Three dimensional Monte Carlo code for photon migration through complex heterogeneous media including the adult human head. , 2002, Optics express.

[33]  T. Kusaka,et al.  Changes in cerebral hemoglobin concentration and oxygen saturation immediately after birth in the human neonate using full-spectrum near infrared spectroscopy. , 2000, Journal of biomedical optics.

[34]  B. Wilson,et al.  Time resolved reflectance and transmittance for the non-invasive measurement of tissue optical properties. , 1989, Applied optics.

[35]  Britton Chance,et al.  Quantitative detection of hemoglobin saturation on piglet brain by near-infrared frequency-domain spectroscopy , 1998, European Conference on Biomedical Optics.

[36]  Clare E Elwell,et al.  Abnormal cerebral haemodynamics in perinatally asphyxiated neonates related to outcome , 1999, Archives of disease in childhood. Fetal and neonatal edition.

[37]  M. Harmer,et al.  Spatially resolved spectroscopy (NIRO-300) does not agree with jugular bulb oxygen saturation in patients undergoing warm bypass surgery , 2001, Canadian journal of anaesthesia = Journal canadien d'anesthesie.

[38]  T. Nishino,et al.  [Regional cerebral oxygen saturation as a monitor of cerebral oxygenation and perfusion during deep hypothermic circulatory arrest and selective cerebral perfusion]. , 1998, Masui. The Japanese journal of anesthesiology.

[39]  Denham S. Ward,et al.  Estimation of Jugular Venous O2 Saturation from Cerebral Oximetry or Arterial O2 Saturation during Isocapnic Hypoxia , 2004, Journal of Clinical Monitoring and Computing.

[40]  Ch. Fusch,et al.  Body Water, Lean Body and Fat Mass of Healthy Children as Measured by Deuterium Oxide Dilution , 1993 .

[41]  [Evaluation of cerebral circulation during cardiopulmonary bypass using near-infrared spectroscopy]. , 1998, The Japanese journal of thoracic and cardiovascular surgery : official publication of the Japanese Association for Thoracic Surgery = Nihon Kyobu Geka Gakkai zasshi.

[42]  M. Ferrari,et al.  Brain oxygenation monitoring during cardiopulmonary bypass by near infrared spectroscopy. , 1997, Advances in experimental medicine and biology.