Evaluation of blood glucose concentration measurement using photoacoustic spectroscopy in near-infrared region

Diabetes, a typical lifestyle-related disease, is an important disease presenting risks of various complications such as retinopathy, kidney failure, and nervous neuropathy. To treat diabetes, regular and continual self-measurement of blood glucose concentrations is necessary to maintain blood glucose levels and to prevent complications. Usually, daily measurements are taken using invasive methods such as finger-prick blood sampling. Some non-invasive optical techniques have been proposed to reduce pain and infection risk, however, few practical techniques exist today. To realize highly accurate and practical measurement of blood glucose concentrations, the feasibility of a photoacoustic method using near-infrared light was evaluated. A photoacoustic signal from a solution of glucose in water (+0–5 g/dl) or equine blood (+0–400 mg/dl) was measured using a hydrophone (9 mm diameter) at 800–1800 nm wavelengths. We investigated the relation between the glucose solution concentration and the photoacoustic signal intensity or peak position of the received photoacoustic signal (i.e. speed of sound in solutions). Results show that the signal intensity and sound speed of the glucose solution increase with increased glucose concentration for wavelengths at which light absorbance of glucose is high. For quantitative estimation of the glucose solution concentration, the photoacoustic signal intensity ratio between two wavelengths, at which dependence of the signal intensity on glucose concentration is high and low, was calculated. Results confirmed that the signal intensity ratios increase linearly with the glucose concentration. These analyses verified the feasibility of glucose level estimation using photoacoustic measurement in the near-infrared region.

[1]  R. Esenaliev,et al.  Noninvasive blood glucose monitoring with optical coherence tomography: a pilot study in human subjects. , 2002, Diabetes care.

[2]  P Vadgama Biosensors in the Body. Continuous In Vivo Monitoring , 1998 .

[3]  Markus W. Sigrist,et al.  Glucose sensing in human epidermis using mid-infrared photoacoustic detection , 2012, Biomedical optics express.

[4]  G. B. Christison,et al.  Laser photoacoustic determination of physiological glucose concentrations in human whole blood , 1993, Medical and Biological Engineering and Computing.

[5]  M Shichiri,et al.  Non-invasive blood glucose measurement by Fourier transform infrared spectroscopic analysis through the mucous membrane of the lip: application of a chalcogenide optical fiber system. , 1999, Frontiers of medical and biological engineering : the international journal of the Japan Society of Medical Electronics and Biological Engineering.

[6]  E. V. Thomas,et al.  Noninvasive glucose monitoring in diabetic patients: a preliminary evaluation. , 1992, Clinical chemistry.

[7]  G. Coté,et al.  The use of polarized laser light through the eye for noninvasive glucose monitoring. , 1999, Diabetes technology & therapeutics.

[8]  John Michael Morookian,et al.  Measurement of aqueous glucose in a model anterior chamber using Raman spectroscopy , 2002 .

[9]  Werner Mäntele,et al.  A novel approach to non-invasive glucose measurement by mid-infrared spectroscopy: The combination of quantum cascade lasers (QCL) and photoacoustic detection , 2005 .