Undersampled projection reconstruction for active catheter imaging with adaptable temporal resolution and catheter‐only views

In this study undersampled projection reconstruction (PR) was used for rapid catheter imaging in the heart, employing steady‐state free precession (SSFP) contrast. Active catheters and phased‐array coils were used for combined imaging of anatomy and catheter position in swine. Real‐time imaging of catheter position was performed with relatively high spatial and temporal resolution, providing 2 × 2 × 8 mm spatial resolution and four to eight frames per second. Two interactive features were introduced. The number of projections (Np) was adjusted interactively to trade off imaging speed and artifact reduction, allowing acquisition of high‐quality or high‐frame‐rate images. Thin‐slice imaging was performed, with interactive requests for thick‐slab projection images of the signal received solely from the active catheter. Briefly toggling on catheter‐only projection images was valuable for verifying that the catheter tip was contained within the selected slice, or for locating the catheter when part of it was outside the selected slice. Magn Reson Med 49:216–222, 2003. Published 2003 Wiley‐Liss, Inc.

[1]  A Shankaranarayanan,et al.  A method for fast 3D tracking using tuned fiducial markers and a limited projection reconstruction FISP (LPR‐FISP) sequence , 2001, Journal of magnetic resonance imaging : JMRI.

[2]  J S Lewin,et al.  Segmented k-space and real-time cardiac cine MR imaging with radial trajectories. , 2001, Radiology.

[3]  D C Peters,et al.  Myocardial wall tagging with undersampled projection reconstruction † , 2001, Magnetic resonance in medicine.

[4]  Robert J Lederman,et al.  Incomplete retention after direct myocardial injection , 2002, Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions.

[5]  T Schaeffter,et al.  Real‐time MR fluoroscopy for MR‐guided iliac artery stent placement , 2000, Journal of magnetic resonance imaging : JMRI.

[6]  Jonathan M Sorger,et al.  Catheter-Based Endomyocardial Injection With Real-Time Magnetic Resonance Imaging , 2002, Circulation.

[7]  Volker Rasche,et al.  Continuous radial data acquisition for dynamic MRI , 1995, Magnetic resonance in medicine.

[8]  V Rasche,et al.  Catheter tracking using continuous radial MRI , 1997, Magnetic resonance in medicine.

[9]  E R McVeigh,et al.  Techniques for fast stereoscopic MRI , 2001, Magnetic resonance in medicine.

[10]  Younes Boudjemline,et al.  Steps Toward Percutaneous Aortic Valve Replacement , 2002, Circulation.

[11]  G H Glover,et al.  Projection Reconstruction Techniques for Reduction of Motion Effects in MRI , 1992, Magnetic resonance in medicine.

[12]  D. Peters,et al.  Undersampled projection reconstruction applied to MR angiography , 2000, Magnetic resonance in medicine.

[13]  T M Grist,et al.  Single breath‐hold 3D contrast‐enhanced method for assessment of cardiac function , 2000, Magnetic resonance in medicine.

[14]  A Shankaranarayanan,et al.  Radial keyhole sequences for low field projection reconstruction interventional MRI , 2001, Journal of magnetic resonance imaging : JMRI.

[15]  H. K. Charles,et al.  Catheter‐tracking FOV MR fluoroscopy , 1998, Magnetic resonance in medicine.

[16]  J N Lee,et al.  MR fluoroscopy: Technical feasibility , 1988, Magnetic resonance in medicine.

[17]  J S Lewin,et al.  Invited. Remember true FISP? a high SNR, near 1‐second imaging method for T2‐like contrast in interventional MRI at .2 T , 1998, Journal of magnetic resonance imaging : JMRI.

[18]  Ergin Atalar,et al.  Toward MRI‐guided coronary catheterization: Visualization of guiding catheters, guidewires, and anatomy in real time , 2000, Journal of magnetic resonance imaging : JMRI.

[19]  S. Souza,et al.  Real‐time position monitoring of invasive devices using magnetic resonance , 1993, Magnetic resonance in medicine.

[20]  Ron Kikinis,et al.  Rapid tip tracking with MRI by a limited projection reconstruction technique , 1998, Journal of magnetic resonance imaging : JMRI.

[21]  M D Schnall,et al.  Simultaneous acquisition of multiple resolution images for dynamic contrast enhanced imaging of the breast , 2001, Magnetic resonance in medicine.

[22]  Warren J Manning,et al.  Magnetic Resonance–Guided Coronary Artery Stent Placement in a Swine Model , 2002, Circulation.

[23]  H Eggers,et al.  Projection reconstruction balanced fast field echo for interactive real‐time cardiac imaging , 2001, Magnetic resonance in medicine.

[24]  C J Hardy,et al.  Real‐time interactive MRI on a conventional scanner , 1997, Magnetic resonance in medicine.

[25]  A. Macovski,et al.  Selection of a convolution function for Fourier inversion using gridding [computerised tomography application]. , 1991, IEEE transactions on medical imaging.