Failure mechanism of the interturn insulation of low voltage electric machines fed by pulse-controll

Partial discharges (PDs) occur in the air-filled gaps of enameled wires that are touching. They erode the insulation and consequently lead to an interturn breakdown. This paper describes the failure mechanism of low voltage interturn insulation as a consequence of PDs and shows why and how it is influenced by the insulation design, temperature, and the applied voltage. Understanding the failure mechanism leads to better founded maximal permissible stresses and a proper design of the interturn insulation to avoid premature drive failures.

[1]  E. Persson,et al.  Transient effects in application of PWM inverters to induction motors , 1991 .

[2]  M. Kaufhold,et al.  Failure mechanism of the interturn insulation of low voltage electric machines fed by pulse controlled inverters , 1995, Proceedings of 1995 Conference on Electrical Insulation and Dielectric Phenomena.

[3]  P. Paloniemi,et al.  Accelerated ageing of a partial discharge resistant enameled round wire [motor winding] , 1995, Proceedings:Electrical Electronics Insulation Conference and Electrical Manufacturing & Coil Winding Conference.

[4]  G. C. Stone,et al.  Implications for the application of adjustable speed drive electronics to motor stator winding insulation , 1995 .