Comparison of 2D and 3D algorithms for adding a margin to the gross tumor volume in the conformal radiotherapy planning of prostate cancer.

PURPOSE To evaluate the adequacy of tumor volume coverage using a three-dimensional (3D) margin-growing algorithm compared to a two-dimensional (2D) margin-growing algorithm in the conformal radiotherapy planning of prostate cancer. METHODS AND MATERIALS Two gross tumor volumes (GTV) were segmented in each of 10 patients with localized prostate cancer; prostate gland only (PO) and prostate with seminal vesicles (PSV). A predetermined margin of 10 mm was applied to these two groups (PO and PSV) using both 2D and 3D margin-growing algorithms. The 2D algorithm added a transaxial margin to each GTV slice, whereas the 3D algorithm added a volumetric margin all around the GTV. The true planning target volume (PTV) was defined as the region delineated by the 3D algorithm. The adequacy of geometric coverage of the GTV by the two algorithms was examined in a series of transaxial planes throughout the target volume. RESULTS The 2D margin-growing algorithm underestimated the PTV by 17% (range 12-20) in the PO group and by 20% (range 13-28) for the PSV group when compared to the 3D-margin algorithm. For the PO group, the mean transaxial difference between the 2D and 3D algorithm was 3.8 mm inferiorly (range 0-20), 1.8 mm centrally (range 0-9), and 4.4 mm superiorly (range 0-22). Considering all of these regions, the mean discrepancy anteriorly was 5.1 mm (range 0-22), posteriorly 2.2 (range 0-20), right border 2.8 mm (range 0-14), and left border 3.1 mm (range 0-12). For the PSV group, the mean discrepancy in the inferior region was 3.8 mm (range 0-20), central region of the prostate was 1.8 mm ( range 0-9), the junction region of the prostate and the seminal vesicles was 5.5 mm (range 0-30), and the superior region of the seminal vesicles was 4.2 mm (range 0-55). When the different borders were considered in the PSV group, the mean discrepancies for the anterior, posterior, right, and left borders were 6.4 mm (range 0-55), 2.5 mm (range 0-20), 2.6 mm (range 0-14), and 3.9 mm (range 0-45), respectively. Underestimation of the required margin with the 2D algorithm occurred when the transaxial definition of the GTV shifted in position significantly between successive adjacent slices, resulting in transaxial discrepancies of up to 22 mm and 55 mm, respectively, for the PO and PSV groups. In the superior regions, the 2D algorithm was inadequate, often providing a margin of less than 3 mm compared to the 10 mm margin delineated by the 3D algorithm. CONCLUSION This study illustrates that target margins added by a laminar method in the transaxial plane are inadequate for covering a 3D tumor volume so that a margin-growing algorithm which fully takes into account the 3D shape of the GTV should be used. If a 2D-margin method is utilized, an appreciation of spatial margins in 3D is required.

[1]  C H Ketting,et al.  Consistency of three-dimensional planning target volumes across physicians and institutions. , 1997, International journal of radiation oncology, biology, physics.

[2]  Douglas L. Jones ICRU Report 50—Prescribing, Recording and Reporting Photon Beam Therapy , 1994 .

[3]  P Kijewski,et al.  Analysis of prostate and seminal vesicle motion: implications for treatment planning. , 1996, International journal of radiation oncology, biology, physics.

[4]  D. Gladstone,et al.  A numerical simulation of organ motion and daily setup uncertainties: implications for radiation therapy. , 1997, International journal of radiation oncology, biology, physics.

[5]  I. Kalet,et al.  Three dimensional planning target volumes: a model and a software tool. , 1995, International Journal of Radiation Oncology, Biology, Physics.

[6]  J C Stroom,et al.  Automatic calculation of three-dimensional margins around treatment volumes in radiotherapy planning. , 1997, Physics in medicine and biology.

[7]  G E Hanks,et al.  Conformal static field radiation therapy treatment of early prostate cancer versus non-conformal techniques: a reduction in acute morbidity. , 1992, International journal of radiation oncology, biology, physics.

[8]  J L Bedford,et al.  A digital method for computing target margins in radiotherapy. , 1998, Medical physics.

[9]  C. Coleman,et al.  Analysis of prostate and seminal vesicle motion , 1993 .

[10]  R Mohan,et al.  The biological basis and clinical application of three-dimensional conformal external beam radiation therapy in carcinoma of the prostate. , 1994, Seminars in oncology.

[11]  L. Verhey,et al.  The value of nonuniform margins for six-field conformal irradiation of localized prostate cancer. , 1995, International journal of radiation oncology, biology, physics.

[12]  S. Webb The Physics of Conformal Radiotherapy: Advances in Technology , 1997 .

[13]  C. Perez,et al.  Technical and tumor-related factors affecting outcome of definitive irradiation for localized carcinoma of the prostate. , 1993, International journal of radiation oncology, biology, physics.

[14]  R Mohan,et al.  A method of incorporating organ motion uncertainties into three-dimensional conformal treatment plans. , 1996, International journal of radiation oncology, biology, physics.

[15]  L M Fagan,et al.  Evaluation of an expert system producing geometric solids as output. , 1995, Proceedings. Symposium on Computer Applications in Medical Care.

[16]  S L Schoeppel,et al.  Treatment planning issues related to prostate movement in response to differential filling of the rectum and bladder. , 1991, International journal of radiation oncology, biology, physics.

[17]  Lawrence M. Fagan,et al.  Automated planning target volume generation: an evaluation pitting a computer-based tool against human experts. , 1997, International journal of radiation oncology, biology, physics.

[18]  Chantal Ginestet,et al.  Acute toxicity in pelvic radiotherapy; a randomised trial of conformal versus conventional treatment , 1997 .

[19]  C. Pelizzari,et al.  Evaluation of changes in the size and location of the prostate, seminal vesicles, bladder, and rectum during a course of external beam radiation therapy. , 1995, International journal of radiation oncology, biology, physics.

[20]  H. Sandler,et al.  Dose escalation for stage C (T3) prostate cancer: minimal rectal toxicity observed using conformal therapy. , 1992, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.