A simple analytical solution to the three-compartment pharmacokinetic model suitable for computer-controlled infusion pumps

The disposition of many drugs following an intravenous bolus injection can be described by a biexponential or triexponential equation. Computer-controlled infusion pumps have been developed which dose intravenous drugs based on models of drug disposition. These pumps can maintain steady plasma drug concentrations and facilitate controlled increases and decreases in drug concentration, enhancing titration of intravenous drugs. Several investigators have proposed analytical solutions to the biexponential and triexponential disposition functions for use in computer-controlled infusion pumps. Because of the complexity of these analytical solutions, other investigators have used numerical techniques to approximate the analytical solution. The authors have derived an extremely simple analytical solution to polyexponential disposition functions. This solution simplifies both the prediction of the plasma drug concentration by a computer-controlled infusion pump and the stepwise calculation of the infusion rate required to maintain constant plasma drug concentrations.<<ETX>>

[1]  James C. Scott,et al.  Pharmacokinetics of fentanyl administered by computer-controlled infusion pump. , 1990, Anesthesiology.

[2]  D B Raemer,et al.  The prospective use of population pharmacokinetics in a computer-driven infusion system for alfentanil. , 1990, Anesthesiology.

[3]  J.R. Jacobs,et al.  Analytical solution to the three-compartment pharmacokinetic model , 1988, IEEE Transactions on Biomedical Engineering.

[4]  James C. Scott,et al.  Testing computer-controlled infusion pumps by simulation. , 1988, Anesthesiology.

[5]  D R Stanski,et al.  Evaluating the Accuracy of Using Population Pharmacokinetic Data to Predict Plasma Concentrations of Alfentanil , 1988, Anesthesiology.

[6]  D R Stanski,et al.  Decreased fentanyl and alfentanil dose requirements with age. A simultaneous pharmacokinetic and pharmacodynamic evaluation. , 1987, The Journal of pharmacology and experimental therapeutics.

[7]  D R Stanski,et al.  An evaluation of the accuracy of pharmacokinetic data for the computer assisted infusion of alfentanil. , 1985, British journal of anaesthesia.

[8]  J A Spain,et al.  Computer‐assisted Continuous Infusions of Fentanyl during Cardiac Anesthesia: Comparison with a Manual Method , 1985, Anesthesiology.

[9]  Louis C. Sheppard,et al.  Computer-Assisted Continuous Infusion of the Intravenous Analgesic Fentanyl During General Anesthesia-An Interactive System , 1985, IEEE Transactions on Biomedical Engineering.

[10]  R. Süverkrüp Segmentally continuous input functions in linear multicompartment systems. , 1985, Journal of pharmaceutical sciences.

[11]  D E Wurster,et al.  Simulation package for multiple intravenous infusions of two compartment pharmacokinetic drugs. , 1981, International journal of bio-medical computing.

[12]  Lewis B. Sheiner,et al.  Simultaneous modeling of pharmacokinetics and pharmacodynamics: Application to d‐tubocurarine , 1979 .

[13]  E. Krüger-Thiemer,et al.  Continuous intravenous infusion and multicompartment accumulation. , 1968, European journal of pharmacology.

[14]  J. R. Jacobs,et al.  Algorithm for optimal linear model-based control with application to pharmacokinetic model-driven drug delivery , 1990, IEEE Transactions on Biomedical Engineering.