Registration-based filtering: An acceptable tool for noise reduction in left ventricular dynamic rotational angiography images?

VT ablations could benefit from Dynamic 3D (4D) left ventricle (LV) visualization as road-map for anatomy-guided procedures. We developed a registration-based method that combines information of several cardiac phases to filter out noise and artifacts in low-dose 3D Rotational Angiography (3DRA) images. This also enables generation of accurate multi-phase surface models by semi-automatic segmentation (SAS). The method uses B-spline non-rigid inter-phase registration (IPR) and subsequent averaging of the registered 3DRA images of 4 cardiac phases, acquired with a slow atrial pacing protocol, and was validated on data from 5 porcine experiments. IPR parameter settings were optimized against manual delineations of the LVs using a composed similarity score (Q), dependent on DICE-coefficient, RMSDistance, Hausdorff (HD) and the percentage of inter-surface distances ≤3mm and ≤4mm. The latter are clinically acceptable error cut-off values. Validation was performed after SAS for varying voxel intensity thresholds (ISO), by comparison between models with and without prior use of IPR. Distances to the manual delineations at optimal ISO were reduced to ≤3mm for 95.6±2.7% and to ≤4mm for 97.1±2.0% of model surfaces. Improved quality was proven by significant mean Q-increase irrespective of ISO (7.6% at optimal ISO (95%CI 4.6-10.5,p<0.0001)). Quality improvement was more important at suboptimal ISO values. Significant (p<0.0001) differences were also noted in HD (-20.5%;95%CI -12.1%-- 29.0%), RMSD (-28.3%;95%CI -21.7%--35.0%) and DICE (1.7%;95%CI 0.9%-2.6%). Generating 4D LV models proved feasible, with sufficient accuracy for clinical applications, opening the perspective of more accurate overlay and guidance during ablation in locations with high degrees of movement.

[1]  Johan Nuyts,et al.  Metal artifact reduction in computed tomography using local models in an image block-iterative scheme. , 2012, Medical physics.

[2]  H. Heidbuchel,et al.  Cardiac three-dimensional rotational angiography can be performed with low radiation dose while preserving image quality. , 2013, Europace.

[3]  H. Heidbuchel,et al.  Three-dimensional cardiac rotational angiography: effective radiation dose and image quality implications. , 2010, Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology.

[4]  Thorsten M Buzug,et al.  A fully 3D approach for metal artifact reduction in computed tomography. , 2012, Medical physics.

[5]  Fei Zuo,et al.  Real-time lesion assessment using a novel combined ultrasound and radiofrequency ablation catheter. , 2011, Heart rhythm.

[6]  Max A. Viergever,et al.  elastix: A Toolbox for Intensity-Based Medical Image Registration , 2010, IEEE Transactions on Medical Imaging.

[7]  L. Feldkamp,et al.  Practical cone-beam algorithm , 1984 .

[8]  F. Maes,et al.  Biplane three-dimensional augmented fluoroscopy as single navigation tool for ablation of atrial fibrillation: accuracy and clinical value. , 2008, Heart rhythm.

[9]  Piet Claus,et al.  A new approach for prospectively gated cardiac rotational angiography , 2013, Medical Imaging.

[10]  Joachim Hornegger,et al.  4-D motion field estimation by Combined Multiple Heart Phase Registration (CMHPR) for cardiac C-arm data , 2012, 2012 IEEE Nuclear Science Symposium and Medical Imaging Conference Record (NSS/MIC).

[11]  Babak Movassaghi,et al.  Segmentation and registration of three-dimensional rotational angiogram on live fluoroscopy to guide atrial fibrillation ablation: a new online imaging tool. , 2009, Heart rhythm.

[12]  H Bosmans,et al.  Effective dose analysis of three-dimensional rotational angiography during catheter ablation procedures , 2010, Physics in medicine and biology.