Automatic ventilation control algorithm considering the indoor environmental quality factors and occupant ventilation behavior using a logistic regression model

Abstract Building occupants find it difficult to achieve the optimal indoor environment quality (IEQ) through natural ventilation. To solve this problem, this study aimed to develop an automatic ventilation control algorithm considering the IEQ factors and occupant ventilation behavior. The algorithm was developed in four steps: (i) real-time collection of data on the IEQ factors and occupant ventilation behavior; (ii) development of the automatic ventilation control algorithm using logistic regression; (iii) determination of the automatic ventilation control algorithm using receiver operating characteristic curve analysis; and (iv) evaluation of the automatic ventilation control algorithm's performance according to the indoor environmental standards. Through this process, the logistic regression model with ridge regression (area under curve: 0.865), with the highest classification accuracy, was selected. Then Youden's index was used to define the decision criterion (i.e., optimal cutoff value) for the logistic regression model. As a result, the decision criterion for opening and closing the windows or doors was 0.533. When the developed algorithm was compared with the indoor environmental standards to analyze its performance, the compliance rate of the opening of the windows or doors based on the monitored data was 77.6%, but it increased to 99% based on the data classified by the developed algorithm. It is expected that if the automatic ventilation control algorithm is embedded in a building ventilation system, which is connected to various IEQ measurement sensors, it will offer a customized building ventilation system to the building occupants.

[1]  P. Fanger,et al.  Extension of the PMV model to non-air-conditioned buildings in warm climates , 2002 .

[2]  Joe Stork,et al.  Middle East oil and the energy crisis , 1975 .

[3]  Michael A. Humphreys,et al.  Updating the adaptive relation between climate and comfort indoors; new insights and an extended database , 2013 .

[4]  Wallace E. Oates,et al.  Tightening Environmental Standards: The Benefit-Cost or the No-Cost Paradigm? , 1995 .

[5]  Dirk Müller,et al.  Analysis of occupants' behavior related to the use of windows in German households , 2016 .

[6]  Dongqun Xu,et al.  Systematic review and meta-analysis of the adverse health effects of ambient PM2.5 and PM10 pollution in the Chinese population. , 2015, Environmental research.

[7]  Zoran Bursac,et al.  Purposeful selection of variables in logistic regression , 2008, Source Code for Biology and Medicine.

[8]  D Norbäck,et al.  Asthmatic symptoms and volatile organic compounds, formaldehyde, and carbon dioxide in dwellings. , 1995, Occupational and environmental medicine.

[9]  A. Worster,et al.  Understanding receiver operating characteristic (ROC) curves. , 2006, CJEM.

[10]  Lindsay Baker,et al.  A History of School Design and Its Indoor Environmental Standards, 1900 to Today. , 2012 .

[11]  Bjarne W. Olesen,et al.  Window opening behaviour modelled from measurements in Danish dwellings , 2013 .

[12]  S. Joshi,et al.  The sick building syndrome , 2008, Indian journal of occupational and environmental medicine.

[13]  Judy Sparer,et al.  Sick-building syndrome , 1997, The Lancet.

[14]  A Kramer,et al.  [Air pollution by volatile organic compounds (VOC) and health complaints]. , 2000, Deutsche medizinische Wochenschrift.

[15]  Erling B. Andersen,et al.  Logistic Regression Analysis , 1994 .

[16]  P O Fanger,et al.  Impact of indoor air temperature and humidity in an office on perceived air quality, SBS symptoms and performance. , 2004, Indoor air.

[17]  David R. Anderson,et al.  Model selection and multimodel inference : a practical information-theoretic approach , 2003 .

[18]  Nan Li,et al.  Probability of occupant operation of windows during transition seasons in office buildings , 2015 .

[19]  David P. Wyon,et al.  The effects of indoor air quality on performance, behaviour and productivity , 2005 .

[20]  P. Fanger Moderate Thermal Environments Determination of the PMV and PPD Indices and Specification of the Conditions for Thermal Comfort , 1984 .

[21]  Alberto Giretti,et al.  Stochastic behavioural models of occupants' main bedroom window operation for UK residential buildings , 2017 .

[22]  Isaac Turiel,et al.  Indoor air quality and human health , 1985 .

[23]  T. Sterling,et al.  Indirect health effects of relative humidity in indoor environments. , 1986, Environmental health perspectives.

[24]  J. Hanley,et al.  The meaning and use of the area under a receiver operating characteristic (ROC) curve. , 1982, Radiology.

[25]  W. Fisk,et al.  Is CO2 an Indoor Pollutant? Direct Effects of Low-to-Moderate CO2 Concentrations on Human Decision-Making Performance , 2012, Environmental health perspectives.

[26]  Juha Vinha,et al.  Carbon dioxide permeability of building materials and their impact on bedroom ventilation need , 2017 .

[27]  Francesca Stazi,et al.  Indoor air quality and thermal comfort optimization in classrooms developing an automatic system for windows opening and closing , 2017 .

[28]  Standard Ashrae Thermal Environmental Conditions for Human Occupancy , 1992 .

[29]  K. Steemers,et al.  Time-dependent occupant behaviour models of window control in summer , 2008 .

[30]  Sebastian Herkel,et al.  Towards a model of user behaviour regarding the manual control of windows in office buildings , 2008 .

[31]  Rita Streblow,et al.  CO2 based occupancy detection algorithm: Experimental analysis and validation for office and residential buildings , 2015 .

[32]  B. Reiser,et al.  Estimation of the Youden Index and its Associated Cutoff Point , 2005, Biometrical journal. Biometrische Zeitschrift.

[33]  Darren Robinson,et al.  Interactions with window openings by office occupants , 2009 .

[34]  E W Steyerberg,et al.  Stepwise selection in small data sets: a simulation study of bias in logistic regression analysis. , 1999, Journal of clinical epidemiology.

[35]  Peder Wolkoff Indoor air humidity, air quality, and health - An overview. , 2018, International journal of hygiene and environmental health.

[36]  Peter Barrett,et al.  Factors influencing occupants’ blind-control behaviour in a naturally ventilated office building , 2012 .

[37]  Tianzhen Hong,et al.  A data-mining approach to discover patterns of window opening and closing behavior in offices , 2014 .

[38]  J. F. Nicol Characterising occupant behaviour in buildings : towards a stochastic model of occupant use of windows, lights, blinds, heaters and fans , 2001 .

[39]  Joseph Andrew Clarke,et al.  Using results from field surveys to predict the effect of open windows on thermal comfort and energy use in buildings , 2007 .

[40]  Darren Robinson,et al.  Verification of stochastic models of window opening behaviour for residential buildings , 2012 .

[41]  Peter V. Nielsen,et al.  Indoor Environmental Modelling: Chapter 34 in ASHRAE Handbook, Fundamentals , 2005 .

[42]  E. George The Variable Selection Problem , 2000 .