Quantitative chemical exchange sensitive MRI using irradiation with toggling inversion preparation

Chemical exchange (CE) sensitive MRI contrast acquired with an off‐resonance irradiation pulse is affected by other relaxation mechanisms, such as longitudinal and transverse relaxations. In particular, for intermediate CEs, the effect of transverse relaxation often dominates CE contrast. Since water relaxation rates can change significantly in many pathological conditions or during physiological challenge, it is crucial to separate these relaxation effects in order to obtain pure CE contrast. Here we proposed a novel acquisition scheme in which a toggling inversion pulse is applied prior to the off‐resonance irradiation. By combined acquisition of irradiation images with and without an inversion pulse at both the labile proton frequency and the reference frequency, longitudinal and transverse relaxation contributions are cancelled, and the quantification of CE parameters, such as the exchange rate and the labile proton concentration, can be simplified. Furthermore, the CE‐mediated relaxation rate can be readily determined with a relatively short irradiation pulse and without approaching the steady state, therefore, reducing the limitations on hardware and specific absorption rate requirements. The signal characteristics of the proposed method are evaluated by numerical simulations and phantom experiments. Magn Reson Med, 2012. © 2012 Wiley Periodicals, Inc.

[1]  Jinyuan Zhou,et al.  Quantitative description of the asymmetry in magnetization transfer effects around the water resonance in the human brain , 2007, Magnetic resonance in medicine.

[2]  Asla Pitkänen,et al.  Quantitative magnetic resonance imaging assessment of cerebral ischemia in rat using on‐resonance T1 in the rotating frame , 1999, Magnetic resonance in medicine.

[3]  Ravinder Reddy,et al.  In vivo mapping of brain myo-inositol , 2011, NeuroImage.

[4]  Jinyuan Zhou,et al.  Detection of the Ischemic Penumbra Using pH-Weighted MRI , 2007, Journal of cerebral blood flow and metabolism : official journal of the International Society of Cerebral Blood Flow and Metabolism.

[5]  On‐ and off‐resonance T1ρ MRI in acute cerebral ischemia of the rat , 2003, Magnetic resonance in medicine.

[6]  Risto A Kauppinen,et al.  Proton transfer ratio, lactate, and intracellular pH in acute cerebral ischemia , 2007, Magnetic resonance in medicine.

[7]  R M Henkelman,et al.  Modeling magnetization transfer for biological-like systems using a semi-solid pool with a super-Lorentzian lineshape and dipolar reservoir. , 1995, Journal of magnetic resonance. Series B.

[8]  Tao Jin,et al.  MR imaging of the amide‐proton transfer effect and the pH‐insensitive nuclear overhauser effect at 9.4 T , 2013, Magnetic resonance in medicine.

[9]  Jinyuan Zhou,et al.  Amide proton transfer MR imaging of prostate cancer: A preliminary study , 2011, Journal of magnetic resonance imaging : JMRI.

[10]  A Gregory Sorensen,et al.  Correction for artifacts induced by B0 and B1 field inhomogeneities in pH‐sensitive chemical exchange saturation transfer (CEST) imaging , 2007, Magnetic resonance in medicine.

[11]  Phillip Zhe Sun,et al.  Association between pH-Weighted Endogenous Amide Proton Chemical Exchange Saturation Transfer MRI and Tissue Lactic Acidosis during Acute Ischemic Stroke , 2011, Journal of cerebral blood flow and metabolism : official journal of the International Society of Cerebral Blood Flow and Metabolism.

[12]  M. Garwood,et al.  Magnetization transfer using inversion recovery during off-resonance irradiation. , 2011, Magnetic resonance imaging.

[13]  Frederick Kelcz,et al.  Off‐resonance spin locking for MR imaging , 1994, Magnetic resonance in medicine.

[14]  Phillip Zhe Sun,et al.  Simplified quantification of labile proton concentration‐weighted chemical exchange rate (kws) with RF saturation time dependent ratiometric analysis (QUESTRA): Normalization of relaxation and RF irradiation spillover effects for improved quantitative chemical exchange saturation transfer (CEST) MRI , 2012, Magnetic resonance in medicine.

[15]  R. Kauppinen,et al.  Quantitative magnetic resonance imaging assessment of cerebral ischemia in rat using on-resonance T(1) in the rotating frame. , 1999, Magnetic resonance in medicine.

[16]  Tao Jin,et al.  Spin‐locking versus chemical exchange saturation transfer MRI for investigating chemical exchange process between water and labile metabolite protons , 2011, Magnetic resonance in medicine.

[17]  Oleg Trott,et al.  R1rho relaxation outside of the fast-exchange limit. , 2002, Journal of magnetic resonance.

[18]  Gil Navon,et al.  Assessment of glycosaminoglycan concentration in vivo by chemical exchange-dependent saturation transfer (gagCEST) , 2008, Proceedings of the National Academy of Sciences.

[19]  Jinyuan Zhou,et al.  Using the amide proton signals of intracellular proteins and peptides to detect pH effects in MRI , 2003, Nature Medicine.

[20]  K. Akasaka Longitudinal relaxation of protons under cross saturation and spin diffusion , 1981 .

[21]  Gottfried Otting,et al.  Proton exchange rates from amino acid side chains— implications for image contrast , 1996, Magnetic resonance in medicine.

[22]  A Gregory Sorensen,et al.  Imaging pH using the chemical exchange saturation transfer (CEST) MRI: Correction of concomitant RF irradiation effects to quantify CEST MRI for chemical exchange rate and pH , 2008, Magnetic resonance in medicine.

[23]  R. Ishima,et al.  Proton spin relaxation in biopolymers at high magnetic fields , 1990 .

[24]  C. Morrison,et al.  A Model for Magnetization Transfer in Tissues , 1995, Magnetic resonance in medicine.

[25]  Ravinder Reddy,et al.  On B1 inhomogeneity correction of in vivo human brain glutamate chemical exchange saturation transfer contrast at 7T , 2013, Magnetic resonance in medicine.

[26]  John A. Detre,et al.  Magnetic Resonance Imaging of Glutamate , 2011, Nature Medicine.

[27]  R S Balaban,et al.  A new class of contrast agents for MRI based on proton chemical exchange dependent saturation transfer (CEST). , 2000, Journal of magnetic resonance.

[28]  Peter C M van Zijl,et al.  MRI detection of glycogen in vivo by using chemical exchange saturation transfer imaging (glycoCEST) , 2007, Proceedings of the National Academy of Sciences.

[29]  Erik Tryggestad,et al.  Differentiation between glioma and radiation necrosis using molecular magnetic resonance imaging of endogenous proteins and peptides , 2010, Nature Medicine.

[30]  Yrjö Hiltunen,et al.  Estimation of the Onset Time of Cerebral Ischemia Using T1&rgr; and T2 MRI in Rats , 2010, Stroke.

[31]  Thomas Benner,et al.  Investigation of optimizing and translating pH‐sensitive pulsed‐chemical exchange saturation transfer (CEST) imaging to a 3T clinical scanner , 2008, Magnetic resonance in medicine.

[32]  Ileana Hancu,et al.  A concentration‐independent method to measure exchange rates in PARACEST agents , 2010, Magnetic resonance in medicine.

[33]  Craig K. Jones,et al.  Four‐pool modeling of proton exchange processes in biological systems in the presence of MRI–paramagnetic chemical exchange saturation transfer (PARACEST) agents , 2008, Magnetic resonance in medicine.

[34]  Peter C M van Zijl,et al.  High-throughput screening of chemical exchange saturation transfer MR contrast agents. , 2010, Contrast media & molecular imaging.

[35]  Matthew E Merritt,et al.  Numerical solution of the Bloch equations provides insights into the optimum design of PARACEST agents for MRI , 2005, Magnetic resonance in medicine.

[36]  Tao Jin,et al.  Change of the cerebrospinal fluid volume during brain activation investigated by T1ρ-weighted fMRI , 2010, NeuroImage.

[37]  Tao Jin,et al.  Magnetic resonance imaging of the Amine–Proton EXchange (APEX) dependent contrast , 2012, NeuroImage.

[38]  Peter Bachert,et al.  Cartilage quality assessment by using glycosaminoglycan chemical exchange saturation transfer and (23)Na MR imaging at 7 T. , 2011, Radiology.

[39]  Robert E Lenkinski,et al.  pCEST: Positive contrast using Chemical Exchange Saturation Transfer. , 2012, Journal of magnetic resonance.