Determination of critical breakage conditions for double glazing in fire

Abstract Double glazing unit normally demonstrates better fire resistance than single glazing, but the knowledge on its thermal behavior and heat transfer mechanism during fire is limited. In this work, nine double glazing units were heated by a 500 × 500 mm2 pool fire. The incident heat flux, temperature on four surfaces, breakage time and cracking behavior were obtained. The critical breakage conditions for interior and exterior panes were determined through gradually decreasing the glass-burner distance from 750 mm to 450 mm. It is established that in double glazing the pane at ambient side can withstand significantly more time than the pane exposed to fire. The critical temperature difference for interior pane is 60 °C; the critical temperature of exterior pane breakage is much higher due to no frame-covered area. In addition, the heat flux at the time of crack initiation is 6 kW/m2 for the pane at fire side, while more than 25 kW/m2 for ambient side pane. To reveal the heat transfer mechanism in glazing-air-glazing, theoretical and numerical investigations are also performed, which agrees well with the experimental results.

[1]  Jim Shields,et al.  Behaviour of Double Glazing in Corner Fires , 2005 .

[2]  Nadia C. L. Chow,et al.  Apron design for protecting double‐skin façade fires , 2015 .

[3]  G. W. H. Silcock,et al.  Performance of a single glazing assembly exposed to a fire in the centre of an enclosure , 2002 .

[4]  Brent Wedding,et al.  Measurements of High‐Temperature Absorption Coefficients of Glasses , 1975 .

[5]  A. Abdel-azim Fundamentals of Heat and Mass Transfer , 2011 .

[6]  J. Xamán,et al.  Thermal performance of a double pane window with a solar control coating for warm climate of Mexico , 2016 .

[7]  Craig L. Beyler,et al.  An Experimental Investigation of Glass Breakage in Compartment Fires , 1991 .

[8]  K. M. Liew,et al.  Experimental Study on Thermal Breakage of Four-Point Fixed Glass Façade , 2014 .

[9]  K. Hollands,et al.  Heat Transfer by Natural Convection Across Vertical and Inclined Air Layers , 1982 .

[10]  Michael S. Klassen,et al.  Transmission Through and Breakage of Single and Multi-Pane Glazing Due to Radiant Exposure: State of Research , 2010 .

[11]  Jennifer X. Wen,et al.  Thermal breakage of window glass in room fires conditions – Analysis of some important parameters , 2012 .

[12]  Takao Wakamatsu,et al.  An Experimental Study On Glass Cracking And Fallout By Radiant Heat Exposure , 2000 .

[13]  Yu Wang,et al.  A stochastic analysis of glass crack initiation under thermal loading , 2014 .

[14]  Umarani Gunasekaran,et al.  Facades of Tall Buildings - State of the Art , 2010 .

[15]  Jun-Seok Nam,et al.  Experimental and Numerical Studies on the Failure of Curtain Wall Double Glazed for Radiation Effect , 2015 .

[16]  Samuel L. Manzello,et al.  An Experimental Determination of a Real Fire Performance of a Non-Load Bearing Glass Wall Assembly , 2007 .

[17]  Yu Wang,et al.  Fracture behavior of framing coated glass curtain walls under fire conditions , 2015 .

[18]  Patrick J. Pagni,et al.  Thermal Breakage of Double-Pane Glazing By Fire , 1998 .

[19]  Guohui Gan,et al.  Thermal transmittance of multiple glazing: computational fluid dynamics prediction , 2001 .

[20]  H. W. Emmons,et al.  The Needed Fire Science , 1986 .

[21]  Patrick J. Pagni Causes of the 20 October 1991 Oakland Hills conflagration , 1993 .

[22]  Yu Wang,et al.  Experimental study on critical breaking stress of float glass under elevated temperature , 2014 .

[23]  G. W. H. Silcock,et al.  Performance of a single glazing assembly exposed to enclosure corner fires of increasing severity , 2001 .

[24]  Isabel Pérez-Grande,et al.  Influence of glass properties on the performance of double-glazed facades , 2005 .

[25]  Liu Yong Study of heat release rate of normal heptane , 2006 .

[26]  Olavi Keski-Rahkonen,et al.  Breaking of Window Glass Close to Fire , 1988 .

[27]  Yu Wang,et al.  Influence of fire location on the thermal performance of glass façades , 2016 .

[28]  Frank P. Incropera,et al.  Fundamentals of Heat and Mass Transfer , 1981 .

[29]  K. Kang,et al.  Assessment of a model development for window glass breakage due to fire exposure in a field model , 2009 .

[30]  G. Heskestad,et al.  Dynamics of the fire plume , 1998, Philosophical Transactions of the Royal Society of London. Series A: Mathematical, Physical and Engineering Sciences.

[31]  Orhan Aydin,et al.  Conjugate heat transfer analysis of double pane windows , 2006 .

[32]  Michael Spearpoint,et al.  A Probabilistic Model for the Fallout Area of Single Glazing under Radiant Heat Exposure , 2014 .