Quantum cascade laser-based sensors for the detection of exhaled carbon monoxide

Carbon monoxide (CO) is an important biomarker as it originates in the human body from the heme (component of hemoglobin) degradation. Tunable laser absorption spectroscopy in the mid-infrared wavelength region is used for sensitive trace gas sensing of exhaled carbon monoxide (CO). Based on a quantum cascade laser emitting at 4.61 µm, two different spectroscopic methods are investigated: off-axis integrated cavity output spectroscopy (OA-ICOS) and wavelength modulation 2f/1f spectroscopy (WMS). The optical sensors integrate a slow feedback system to correct for wavelength drifts improving their stability over days. Both approaches demonstrate a high reproducibility and sensitivity during online measurements of exhaled human breath. Considering the detection limit to be the equal to the standard deviation of the background fluctuations, the noise-equivalent detection limit for both OA-ICOS and WMS is 7 ppbv (1-s averaging time), leading to a noise-equivalent absorption sensitivity of 3.1 × 10−7 cm−1 Hz−1/2, which is sufficient for measurements of exhaled CO (eCO). Collection and measurements of eCO samples were investigated, and different exhalation flow rates and breath-holding time were explored, to provide a reliable sampling method for future medical investigations.

[1]  Frans J. M. Harren,et al.  Quantum cascade laser-based carbon monoxide detection on a second time scale from human breath , 2006 .

[2]  I. Horváth,et al.  Exhaled nitric oxide and carbon monoxide in respiratory diseases , 2007, Journal of Breath Research.

[3]  H Sasaki,et al.  Increased carbon monoxide in exhaled air of asthmatic patients. , 1997, American journal of respiratory and critical care medicine.

[4]  P. Montuschi,et al.  Increased carbon monoxide in exhaled air of patients with cystic fibrosis , 1999, Thorax.

[5]  S. Ryter,et al.  Exhaled carbon monoxide as a biomarker of inflammatory lung disease , 2007, Journal of breath research.

[6]  S. Ishizuka,et al.  Relation between exhaled carbon monoxide levels and clinical severity of asthma , 2001, Clinical and experimental allergy : journal of the British Society for Allergy and Clinical Immunology.

[7]  H. Marver,et al.  The enzymatic conversion of heme to bilirubin by microsomal heme oxygenase. , 1968, Proceedings of the National Academy of Sciences of the United States of America.

[8]  A. Kosterev,et al.  Chemical sensors based on quantum cascade lasers , 2002 .

[9]  P. Hering,et al.  Mid-infrared laser spectroscopy for online analysis of exhaled CO , 2010, Journal of breath research.

[10]  D. Stevenson,et al.  Evaluation of a fully automated end-tidal carbon monoxide instrument for breath analysis. , 1996, Clinical chemistry.

[11]  Yixiang Duan,et al.  Breath biomarkers in diagnosis of pulmonary diseases. , 2012, Clinica chimica acta; international journal of clinical chemistry.

[12]  M. Zahniser,et al.  Clinical study of multiple breath biomarkers of asthma and COPD (NO, CO2, CO and N2O) by infrared laser spectroscopy , 2011, Journal of breath research.

[13]  E. J. Moyer,et al.  Design considerations in high-sensitivity off-axis integrated cavity output spectroscopy , 2008 .

[14]  M. Zahniser,et al.  Multicomponent Breath Analysis With Infrared Absorption Using Room-Temperature Quantum Cascade Lasers , 2010, IEEE Sensors Journal.

[15]  E. Ihre,et al.  Exhaled carbon monoxide is not elevated in patients with asthma or cystic fibrosis , 2002, European Respiratory Journal.

[16]  F. Keutsch,et al.  Ultrasensitive near-infrared integrated cavity output spectroscopy technique for detection of CO at 1.57 microm: new sensitivity limits for absorption measurements in passive optical cavities. , 2006, Applied optics.

[17]  P. Barnes,et al.  Exhaled carbon monoxide in childhood asthma. , 1999, The Journal of pediatrics.

[18]  W. J. Williams,et al.  EFFECT OF ERYTHROCYTE DESTRUCTION ON CARBON MONOXIDE PRODUCTION IN MAN. , 1964, The Journal of clinical investigation.

[19]  P. Barnes,et al.  Increase in exhaled carbon monoxide during exacerbations of cystic fibrosis , 2000, Thorax.

[20]  Anthony O'Keefe,et al.  Integrated cavity output analysis of ultra-weak absorption , 1998 .

[21]  Lingyun Wu,et al.  Carbon Monoxide: Endogenous Production, Physiological Functions, and Pharmacological Applications , 2005, Pharmacological Reviews.

[22]  R. Uddman,et al.  Carbon monoxide is endogenously produced in the human nose and paranasal sinuses. , 2000, The Journal of allergy and clinical immunology.

[23]  Joseph R. Stetter,et al.  The properties and applications of amperometric gas sensors , 1992 .

[24]  P. Barnes,et al.  Raised levels of exhaled carbon monoxide are associated with an increased expression of heme oxygenase-1 in airway macrophages in asthma: a new marker of oxidative stress , 1998, Thorax.

[25]  B. Mizaikoff,et al.  Potential and Challenges for Mid-Infrared Sensors in Breath Diagnostics , 2010, IEEE Sensors Journal.

[26]  Denis D Arslanov,et al.  Optical parametric oscillator based off-axis integrated cavity output spectroscopy for rapid chemical sensing. , 2010, Optics letters.

[27]  G. Griffith,et al.  Spectroscopic monitoring of NO traces in plants and human breath: applications and perspectives , 2013 .

[28]  R. Hanson,et al.  Calibration-free wavelength-modulation spectroscopy for measurements of gas temperature and concentration in harsh environments. , 2009, Applied optics.

[29]  W. Miekisch,et al.  Diagnostic potential of breath analysis--focus on volatile organic compounds. , 2004, Clinica chimica acta; international journal of clinical chemistry.

[30]  I. Nikberg,et al.  [Carbon monoxide concentration in the air exhaled by the healthy and the ill]. , 1972, Vrachebnoe delo.

[31]  P. Silkoff Nasal nitric oxide: clue to a diagnosis of ciliary dyskinesia. , 2004, Chest.

[32]  T. Fritsch,et al.  Infrared laser spectroscopy for online recording of exhaled carbon monoxide—a progress report , 2007, Journal of breath research.

[33]  J. Lelieveld,et al.  QUALITAS: A mid-infrared spectrometer for sensitive trace gas measurements based on quantum cascade lasers in CW operation , 2005 .