Dopamine detection with fast-scan cyclic voltammetry used with analog background subtraction.

Fast-scan cyclic voltammetry has been used in a variety of applications and has been shown to be especially useful to monitor chemical fluctuations of neurotransmitters such as dopamine within the mammalian brain. A major limitation of this procedure, however, is the large amplitude of the background current relative to the currents for the solution species of interest. Furthermore, the background tends to drift, and this drift limits the use of digital background subtraction techniques to intervals less than 90 s before distortion of dopamine signals occurs. To minimize the impact of the background, a procedure termed analog background subtraction is reported here. The background is recorded, and its inverse is played back to the current transducer during data acquisition so that it cancels the background in subsequent scans. Background drift still occurs and is recorded, but its magnitude is small compared to the original background. This approach has two advantages. First it allows the use of higher gains in the current transducer, minimizing quantization noise. Second, because the background amplitude is greatly reduced, principal component regression could be used to separate the contributions from drift, dopamine, and pH when appropriate calibrations were performed. We demonstrate the use of this approach with several applications. First, transient dopamine fluctuations were monitored for 15 min in a flowing injection apparatus. Second, evoked release of dopamine was monitored for a similar period in the brain of an anesthetized rat. Third, dopamine was monitored in the brain of freely moving rats over a 30 min interval. By analyzing the fluctuations in each resolved component, we were able to show that cocaine causes significant fluctuations in dopamine concentration in the brain while those for the background and pH remain unchanged from their predrug value.

[1]  Royce W Murray,et al.  Voltammetric detection of metal nanoparticles separated by liquid chromatography. , 2004, Analytical chemistry.

[2]  Edmund R. Malinowski,et al.  Statistical F‐tests for abstract factor analysis and target testing , 1989 .

[3]  Hua Yang,et al.  Voltammetric study of extracellular dopamine near microdialysis probes acutely implanted in the striatum of the anesthetized rat , 2005, Journal of Neuroscience Methods.

[4]  R. Compton,et al.  Marcus theory of outer-sphere heterogeneous electron transfer reactions: dependence of the standard electrochemical rate constant on the hydrodynamic radius from high precision measurements of the oxidation of anthracene and its derivatives in nonaqueous solvents using the high-speed channel electro , 2004, Journal of the American Chemical Society.

[5]  Christian Amatore,et al.  When voltammetry reaches nanoseconds. , 2005, Analytical Chemistry.

[6]  B. J. Venton,et al.  Subsecond detection of physiological adenosine concentrations using fast-scan cyclic voltammetry. , 2007, Analytical chemistry.

[7]  Daniel S Schrock,et al.  Feedback effects in combined fast-scan cyclic voltammetry-scanning electrochemical microscopy. , 2007, Analytical chemistry.

[8]  C. Lefrou,et al.  Is cyclic voltammetry above a few hundred kilovolts per second still cyclic voltammetry , 1990 .

[9]  R. Wightman,et al.  Electrochemical, pharmacological and electrophysiological evidence of rapid dopamine release and removal in the rat caudate nucleus following electrical stimulation of the median forebrain bundle. , 1985, European journal of pharmacology.

[10]  R. Wightman,et al.  Extinction of Cocaine Self-Administration Reveals Functionally and Temporally Distinct Dopaminergic Signals in the Nucleus Accumbens , 2005, Neuron.

[11]  E. Pothos,et al.  Regulation of Quantal Size by Presynaptic Mechanisms , 2000, Reviews in the neurosciences.

[12]  Robert T Kennedy,et al.  Monitoring dopamine in vivo by microdialysis sampling and on-line CE-laser-induced fluorescence. , 2006, Analytical chemistry.

[13]  Lawrence K Duffy,et al.  An ultrastructural analysis of tissue surrounding a microdialysis probe , 1999, Journal of Neuroscience Methods.

[14]  J. B. Justice,et al.  Microdialysis of dopamine interpreted with quantitative model incorporating probe implantation trauma , 2003, Journal of neurochemistry.

[15]  Charles W Bradberry,et al.  Phasic Alterations in Dopamine and Serotonin Release in Striatum and Prefrontal Cortex in Response to Cocaine Predictive Cues in Behaving Rhesus Macaques , 2004, Neuropsychopharmacology.

[16]  W. Charewicz,et al.  Effect of solvent upon competitive liquid-liquid extraction of alkali metal cations by 2-[(sym-dibenzo-16-crown-5)oxy]decanoic acid , 1987 .

[17]  S. Weber,et al.  Recovery of voltammograms by target factor analysis of current-time data in electrochemical detection. , 1990, Analytical chemistry.

[18]  Ingrid Fritsch,et al.  Analysis in ultrasmall volumes: microdispensing of picoliter droplets and analysis without protection from evaporation. , 2004, Analytical chemistry.

[19]  J. B. Justice,et al.  Differences in the Pharmacokinetics of Cocaine in Naive and Cocaine‐Experienced Rats , 1991, Journal of neurochemistry.

[20]  R. Wightman,et al.  Subsecond adsorption and desorption of dopamine at carbon-fiber microelectrodes. , 2000, Analytical chemistry.

[21]  B. Jill Venton,et al.  Psychoanalytical Electrochemistry: Dopamine and Behavior , 2003 .

[22]  J Wang,et al.  Background-current subtraction in voltammetric detection for flow-injection analysis. , 1984, Talanta.

[23]  R. Wightman,et al.  Subsecond dopamine release promotes cocaine seeking , 2003, Nature.

[24]  R. Wightman,et al.  Resolving neurotransmitters detected by fast-scan cyclic voltammetry. , 2004, Analytical chemistry.

[25]  J. Becker,et al.  Dynamic increases in dopamine during paced copulation in the female rat , 2003, The European journal of neuroscience.

[26]  R. Wightman,et al.  Real-time measurement of dopamine fluctuations after cocaine in the brain of behaving rats. , 2005, Proceedings of the National Academy of Sciences of the United States of America.

[27]  A. Michael,et al.  Invasive consequences of using micro-electrodes and microdialysis probes in the brain , 2003 .

[28]  L. Parsons,et al.  Extracellular Concentrations of Cocaine and Dopamine Are Enhanced During Chronic Cocaine Administration , 1990, Journal of neurochemistry.

[29]  R I Shrager,et al.  Deconvolutions based on singular value decomposition and the pseudoinverse: a guide for beginners. , 1994, Journal of biochemical and biophysical methods.

[30]  R. Wightman,et al.  High-speed cyclic voltammetry , 1990 .

[31]  C. Hsueh,et al.  Surface and kinetic enhancement of selectivity and sensitivity in analysis with fast scan voltammetry at scan rates above 1000 V/s , 1997 .

[32]  R. Wightman,et al.  Improving data acquisition for fast-scan cyclic voltammetry. , 1999, Analytical chemistry.

[33]  A. Bard,et al.  Determination of the Kinetic Parameters for the Electroreduction of C60 by Scanning Electrochemical Microscopy and Fast Scan Cyclic Voltammetry , 1993 .

[34]  R. Wightman,et al.  Correlation of local changes in extracellular oxygen and pH that accompany dopaminergic terminal activity in the rat caudate–putamen , 2003, Journal of neurochemistry.

[35]  W. Kutner,et al.  Amperometric and fast scan-rate cyclic voltammetry detection at a microelectrode for gel permeation high-performance liquid chromatography of fullerenes , 1993 .

[36]  M. Hayes,et al.  Background-subtraction of fast-scan cyclic staircase voltammetry at protein-modified carbon-fiber electrodes. , 1998, Biosensors & bioelectronics.

[37]  Su-Moon Park,et al.  Programmed potential sweep voltammetry for lower detection limits. , 2005, Analytical chemistry.

[38]  R. Wightman,et al.  Principles of voltammetry and microelectrode surface states , 1993, Journal of Neuroscience Methods.

[39]  R. Roth,et al.  Cocaine increases extracellular dopamine in rat nucleus accumbens and ventral tegmental area as shown by in vivo microdialysis , 1989, Neuroscience Letters.

[40]  A. Michael,et al.  Voltammetric study of the control of striatal dopamine release by glutamate , 2004, Journal of neurochemistry.

[41]  R. Wightman,et al.  Ultrafast Voltammetry and Voltammetry in Highly Resistive Solutions with Microvoltammetric Electrodes , 1984 .

[42]  Garret D Stuber,et al.  Overoxidation of carbon-fiber microelectrodes enhances dopamine adsorption and increases sensitivity. , 2003, The Analyst.

[43]  R. Wightman,et al.  Detecting subsecond dopamine release with fast-scan cyclic voltammetry in vivo. , 2003, Clinical chemistry.

[44]  Werner G. Kuhr,et al.  Background subtraction for rapid scan voltammetry , 1986 .