An evaluation of nursing tasks.

Functional capacity evaluations have been criticized as being too general in theory and not being accurate enough to determine what tasks an employee can perform. This paper will describe results of a descriptive study that was conducted in a laboratory setting to objectively determine the physical demands of patient transfer tasks performed by nurses. Fifty three tasks were analyzed and broken down into sub-tasks to quantify the peak force required to perform each sub-task in order to determine which tasks pose healthcare workers at highest risk of injury. Dissecting the transfer task into segments allows us to see which part of the task requires high forces on the part of the caregiver. The task can then be modified to eliminate the risk of injury to the caregiver. This modification can be accomplished by using healthcare technology, such as floor based or overhead lifts, friction reducing devices, sit to stand lifts, properly designed slings, and motorized beds/trolleys. Technological solutions are available for some of these high risk tasks and should be implemented where applicable to reduce the force demand and eliminate or reduce the risk of injury to healthcare workers in nursing.

[1]  Vincent Gouttebarge,et al.  Quality of functional capacity evaluation tests : a clinimetric approach , 2008 .

[2]  Leon Straker,et al.  Validity of work-related assessments. , 1999, Work.

[3]  R. Norman,et al.  Biomechanical analysis of peak and cumulative spinal loads during simulated patient-handling activities: a substudy of a randomized controlled trial to prevent lift and transfer injury of health care workers. , 2001, Applied ergonomics.

[4]  W. Marras,et al.  A comprehensive analysis of low-back disorder risk and spinal loading during the transferring and repositioning of patients using different techniques. , 1999, Ergonomics.

[5]  Jenny Strong,et al.  Expert review of an approach to functional capacity evaluation. , 2002, Work.

[6]  A. Nelson,et al.  Friction-Reducing Devices for Lateral Patient Transfers , 2006, AAOHN journal : official journal of the American Association of Occupational Health Nurses.

[7]  A Garg,et al.  A biomechanical and ergonomic evaluation of patient transferring tasks: wheelchair to shower chair and shower chair to wheelchair. , 1991, Ergonomics.

[8]  Thomas R Waters,et al.  When is it safe to manually lift a patient? , 2007, The American journal of nursing.

[9]  A Garg,et al.  A biomechanical and ergonomic evaluation of patient transferring tasks: bed to wheelchair and wheelchair to bed. , 1991, Ergonomics.

[10]  A. Nelson,et al.  Update on Evidence‐Based Practices for Safe Patient Handling and Movement , 2006, Orthopedic Nursing.

[11]  C. Velozo Work evaluations: critique of the state of the art of functional assessment of work. , 1993, The American journal of occupational therapy : official publication of the American Occupational Therapy Association.

[12]  W. Karwowski,et al.  Biomechanical evaluation of nursing tasks in a hospital setting , 2007, Ergonomics.

[13]  L. Wolf,et al.  Reduction in injury rates in nursing personnel through introduction of mechanical lifts in the workplace. , 2003, American journal of industrial medicine.

[14]  G. Pransky,et al.  Practical Aspects of Functional Capacity Evaluations , 2004, Journal of Occupational Rehabilitation.

[15]  M. Lemstra,et al.  The Sensitivity and Specificity of Functional Capacity Evaluations in Determining Maximal Effort: A Randomized Trial , 2004, Spine.