A comparative study of the cytoskeleton binding drugs nocodazole and taxol with a mammalian cell quartz crystal microbalance biosensor: different dynamic responses and energy dissipation effects.

The quartz crystal microbalance (QCM) was used to create piezoelectric whole-cell biosensors utilizing either living endothelial cells (ECs) or the metastatic human mammary cancer cell line MDA-MB-231 adhering to the gold QCM surface under in vitro growth conditions. We utilized the whole-cell QCM biosensors for the detection of the effects of varying concentrations of the microtubule binding drugs taxol and nocodazole by measuring changes in the QCM steady state frequency (Deltaf) and motional resistance (DeltaR), shift values. Using 0.11-50 microM nocodazole, we observed the Deltaf shift values of the biosensors, consisting of 20,000 ECs, to decrease significantly in magnitude (nearly 100%) to a limiting value, in a dose-dependent fashion, over a 5- to 6-h incubation period following drug addition. This effect is consistent with nocodazole's known disruption of intracellular microtubules. On the other hand, 10 microM taxol caused little alteration in Deltaf over the same time period, consistent with its microtubule hyperstabilization effect. When the EC QCM biosensor Deltaf shift values were normalized by the number of ECs found firmly attached to the QCM surface via trypsin removal and electronic counting, the dose curve was shifted to lower nocodazole concentrations, resulting in a more sensitive drug biosensor. The kinetics of the Deltaf decrease with increasing nocodazole concentrations measured by the EC QCM biosensor was found to be similar at all drug concentrations and was well fit by a single first-order exponential decay equation. For all nocodazole doses, t(0.5) was invariant, averaging t(0.5)=0.83+/-0.14 h. These data demonstrate that a single dynamic sensing system within the cell, the microtubules, is disrupted by the addition of nocodazole and this process is sensed by the cell QCM biosensor. This interpretation of the data was confirmed by a fluorescence light microscopy investigation of ECs undergoing treatment with increasing nocodazole doses using a fluorescent antibody to alpha-tubulin. These studies revealed a corresponding loss of the spread morphology of the cells, concomitant with a rearrangement of the extended native microtubules into increasingly large aggregates with the cells eventually lifting from the surface in significant numbers at 50 microM. At 6 microM nocodazole, partial reversibility of the EC QCM biosensor was demonstrated. These results indicate that the EC QCM biosensor can be used to detect and study EC cytoskeleton alterations and dynamics. We suggest the potential of this cellular biosensor for the real-time identification or screening of all classes of biologically active drugs or biological macromolecules that affect cellular attachment and cellular spreading, regardless of their molecular mechanism of action.

[1]  K. Marx,et al.  A quartz crystal microbalance cell biosensor: detection of microtubule alterations in living cells at nM nocodazole concentrations. , 2001, Biosensors & bioelectronics.

[2]  K. Marx,et al.  Quartz crystal microbalance: a useful tool for studying thin polymer films and complex biomolecular systems at the solution-surface interface. , 2003, Biomacromolecules.

[3]  I. Rubinstein,et al.  Physical electrochemistry : principles, methods, and applications , 1995 .

[4]  S. Horwitz,et al.  Novel molecules that interact with microtubules and have functional activity similar to Taxol. , 2001, Drug discovery today.

[5]  Isao Karube,et al.  Computation of equivalent circuit parameters of quartz crystals in contact with liquids and study of liquid properties , 1988 .

[6]  B. Kasemo,et al.  In vitro real-time characterization of cell attachment and spreading , 1998, Journal of materials science. Materials in medicine.

[7]  K. Marx,et al.  Quartz crystal microbalance biosensor study of endothelial cells and their extracellular matrix following cell removal: Evidence for transient cellular stress and viscoelastic changes during detachment and the elastic behavior of the pure matrix. , 2005, Analytical biochemistry.

[8]  M. Cooper,et al.  Profiling molecular interactions using label-free acoustic screening. , 2005, Drug discovery today. Technologies.

[9]  Andreas Janshoff,et al.  Cell adhesion monitoring using a quartz crystal microbalance: comparative analysis of different mammalian cell lines , 1998, European Biophysics Journal.

[10]  K. Marx,et al.  Detection of apoptosis and drug resistance of human breast cancer cells to taxane treatments using quartz crystal microbalance biosensor technology. , 2005, Assay and drug development technologies.

[11]  G. Sauerbrey,et al.  Use of quartz vibration for weighing thin films on a microbalance , 1959 .

[12]  K. Marx,et al.  Quartz Crystal Microbalance Study of Endothelial Cell Number Dependent Differences in Initial Adhesion and Steady‐State Behavior: Evidence for Cell‐Cell Cooperativity in Initial Adhesion and Spreading , 2003, Biotechnology progress.

[13]  R M Nerem,et al.  Hemodynamics and the vascular endothelium. , 1993, Journal of biomechanical engineering.

[14]  Michael B. Thompson,et al.  Interfacial Nucleic Acid Hybridization Studied by Random Primer 32P Labeling and Liquid-Phase Acoustic Network Analysis , 1994 .

[15]  P Wadsworth,et al.  Nanomolar concentrations of nocodazole alter microtubule dynamic instability in vivo and in vitro. , 1997, Molecular biology of the cell.

[16]  K. Marx,et al.  A Quartz Crystal Microbalance Cell Biosensor: Detecting Nocodazole Dependent Microtubule Disruption Dynamics In Living Cells , 2001 .

[17]  K. Pavey Quartz crystal analytical sensors: the future of label-free, real-time diagnostics? , 2002, Expert review of molecular diagnostics.

[18]  M. Thompson,et al.  Electrode modification and the response of the acoustic shear wave device operating in liquids. , 2001, The Analyst.

[19]  M. Ward Principles and applications of the electrochemical quartz crystal microbalance , 1995 .

[20]  T. Ataka,et al.  Reliability of correlation between mass change and resonant frequency change for a viscoelastic-film-coated quartz crystal , 1995 .

[21]  Irina Kaverina,et al.  Microtubule Targeting of Substrate Contacts Promotes Their Relaxation and Dissociation , 1999, The Journal of cell biology.

[22]  Jing Li,et al.  Monitoring of integrin-mediated adhesion of human ovarian cancer cells to model protein surfaces by quartz crystal resonators: evaluation in the impedance analysis mode. , 2005, Biosensors & bioelectronics.

[23]  A. Horwitz,et al.  Integrin cytoplasmic domains: mediators of cytoskeletal linkages and extra- and intracellular initiated transmembrane signaling. , 1993, Current opinion in cell biology.

[24]  G. Sauerbrey Verwendung von Schwingquarzen zur Wägung dünner Schichten und zur Mikrowägung , 1959 .

[25]  E. Salmon,et al.  Positive feedback interactions between microtubule and actin dynamics during cell motility. , 1999, Current opinion in cell biology.

[26]  H. Galla,et al.  Analysis of the composite response of shear wave resonators to the attachment of mammalian cells. , 2000, Biophysical journal.

[27]  M. Thompson,et al.  Adhesion of human platelets to collagen detected by 51Cr labelling and acoustic wave sensor , 1997 .

[28]  Wolfgang Göpel,et al.  A new affinity biosensor: self-assembled thiols as selective monolayer coatings of quartz crystal microbalances , 1996 .

[29]  J. Gordon,et al.  The oscillation frequency of a quartz resonator in contact with liquid , 1985 .

[30]  K. Marx,et al.  Cellular Adhesion and Spreading of Endothelial Cells Monitored in Real Time Using the Quartz Crystal Microbalance , 1998 .

[31]  D. Lauffenburger,et al.  Cell Migration: A Physically Integrated Molecular Process , 1996, Cell.

[32]  K. Marx The Quartz Crystal Microbalance and the Electrochemical QCM: Applications to Studies of Thin Polymer Films, Electron Transfer Systems, Biological Macromolecules, Biosensors, and Cells , 2006 .

[33]  K. Marx,et al.  The Quartz Crystal Microbalance as a Continuous Monitoring Tool for the Study of Endothelial Cell Surface Attachment and Growth , 2000, Biotechnology progress.

[34]  M. Papadaki,et al.  Effects of Fluid Shear Stress on Gene Regulation of Vascular Cells , 1997, Biotechnology progress.

[35]  R. Engerman,et al.  Cell turnover of capillaries. , 1967, Laboratory investigation; a journal of technical methods and pathology.

[36]  K. Marx,et al.  Quartz Crystal Microbalance Measurement of Self‐Assembled Micellar Tubules of the Amphiphilic Decyl Ester of d‐Tyrosine and Their Enzymatic Polymerization , 1999, Biotechnology progress.

[37]  M. D. Ward,et al.  Real‐Time Measurement of Anchorage‐Dependent Cell Adhesion Using a Quartz Crystal Microbalance , 1993, Biotechnology progress.

[38]  George G. Guilbault,et al.  Commercial quartz crystal microbalances-Theory and applications , 1999 .

[39]  B. Kasemo,et al.  The Piezoelectric Quartz Crystal Mass and Dissipation Sensor: A Means of Studying Cell Adhesion , 1998 .

[40]  K. Marx,et al.  Comparative study of electropolymerization versus adsorption of tyrosine and the decyl ester of tyrosine on platinum electrodes , 2002 .

[41]  M. De Brabander,et al.  The effects of methyl (5-(2-thienylcarbonyl)-1H-benzimidazol-2-yl) carbamate, (R 17934; NSC 238159), a new synthetic antitumoral drug interfering with microtubules, on mammalian cells cultured in vitro. , 1976, Cancer research.

[42]  J. Folkman,et al.  Tumor angiogenesis and metastasis--correlation in invasive breast carcinoma. , 1991, The New England journal of medicine.

[43]  George K. Knopf,et al.  Smart Biosensor Technology , 2006 .

[44]  Matthew A Cooper,et al.  Direct quantification of analyte concentration by resonant acoustic profiling. , 2005, Clinical chemistry.

[45]  L. Smilenov,et al.  Focal adhesion motility revealed in stationary fibroblasts. , 1999, Science.