Transport of gaseous pollutants by convective boundary layer around a human body

This study investigates the ability of the human convective boundary layer to transport pollution in a quiescent indoor environment. The impact of the source location in the vicinity of a human body is examined in relation to pollution distribution in the breathing zone and the thickness of the pollution boundary layer. The study, in addition, evaluates the effects of the room air temperature, table positioning, and seated body inclination. The human body is represented by a thermal manikin that has a body shape, size, and surface temperature that resemble those of a real person. The results show that the source location has a considerable influence on the breathing zone pollution concentrations and on the thickness of the pollution boundary layer. The highest breathing zone concentrations are achieved when the pollution is located at the chest, while there is negligible exposure for the pollution emitted at the upper back or behind the chair. The results also indicate that a decrease in personal exposure to pollutants released from or around the human body increases the extent to which the pollution spreads to the surroundings. Reducing the room air temperature or backward body inclination intensifies the transport of the pollution to the breathing zone and increases personal exposure. The front edge of a table positioned at zero distance from the human body can reduce the pollution transport to the breathing zone, or it can increase transport of the clean air from beneath if positioned at a 10-cm (0.33-ft) distance.

[1]  D. Rim,et al.  The influence of chemical interactions at the human surface on breathing zone levels of reactants and products. , 2009, Indoor air.

[2]  A. Melikov,et al.  Experimental investigation of the human convective boundary layer in a quiescent indoor environment , 2014 .

[3]  K W Tham,et al.  Human convection flow in spaces with and without ventilation: personal exposure to floor-released particles and cough-released droplets. , 2015, Indoor air.

[4]  Andrea R. Ferro,et al.  Walking-induced particle resuspension in indoor environments , 2014 .

[5]  Jan Jakub Zajas,et al.  The Thermal Plume above a Standing Human Body Exposed to Different Air Distribution Strategies , 2009 .

[6]  Peter V. Nielsen,et al.  Contaminant Flow in the Microenvironment Between People Under Different Ventilation Conditions , 2008 .

[7]  A. Melikov,et al.  Novel bed integrated ventilation method for hospital patient rooms , 2014 .

[8]  N. Toy,et al.  Natural convection around the human head. , 1975, The Journal of physiology.

[9]  A. Melikov,et al.  Human convective boundary layer and its interaction with room ventilation flow. , 2015, Indoor air.

[10]  Andrea R Ferro,et al.  Elevated personal exposure to particulate matter from human activities in a residence , 2004, Journal of Exposure Analysis and Environmental Epidemiology.

[11]  J. Laverge,et al.  Experimental assessment of exposure to gaseous pollutants from mattresses and pillows while asleep , 2012 .

[12]  R N Cox,et al.  Aerodynamics of the human microenvironment. , 1969, Lancet.

[13]  Henrik Brohus,et al.  Personal Exposure in Displacement Ventilated Rooms , 1996 .

[14]  D. Rim,et al.  Transport of particulate and gaseous pollutants in the vicinity of a human body , 2009 .

[15]  Goodarz Ahmadi,et al.  Computational modeling of effects of thermal plume adjacent to the body on the indoor airflow and particle transport , 2012 .

[16]  Gary S. Settles,et al.  A Computational and Experimental Investigation of the Human Thermal Plume , 2005 .

[17]  M. Glauser,et al.  Flow measurements in indoor office environment , 2008 .

[18]  Arsen Krikor Melikov,et al.  Control of the Free Convective Flow around the Human Body for Enhanced Inhaled Air Quality: Application to a Seat-Incorporated Personalized Ventilation Unit , 2010 .

[19]  Arsen Krikor Melikov,et al.  Air Quality and Thermal Comfort in an Office with Underfloor, Mixing and Displacement Ventilation , 2006 .

[20]  Chandra Sekhar,et al.  Computational fluid dynamics study and evaluation of different personalized exhaust devices , 2013 .

[21]  K. Meyer,et al.  Airflow Characteristics at the Breathing Zone of a Seated Person: Passive Control over the Interaction of the Free Convection Flow and Locally Applied Airflow from Front for Personalized Ventilation Application , 2011 .

[22]  Shuzo Murakami,et al.  Combined simulation of airflow, radiation and moisture transport for heat release from a human body , 2000 .

[23]  Raymond P. Clark,et al.  Some aspects of the airborne transmission of infection , 2009, Journal of The Royal Society Interface.

[24]  Arsen Krikor Melikov,et al.  Impact of personal factors and furniture arrangement on the thermal plume above a sitting occupant , 2012 .

[25]  A. Melikov Personalized ventilation. , 2004, Indoor air.

[26]  L. Wallace Correlations of Personal Exposure to Particles with Outdoor Air Measurements: A Review of Recent Studies , 2000 .

[27]  Shuzo Murakami,et al.  Study on inhalation region by means of CFD analysis and experiment , 2005 .

[28]  Tracy L. Thatcher,et al.  Deposition, resuspension, and penetration of particles within a residence , 1995 .

[29]  A. Melikov,et al.  Control of exposure to exhaled air from sick occupant with wearable personal exhaust unit , 2014 .

[30]  C. Wysocki,et al.  Facts, fallacies, fears, and frustrations with human pheromones. , 2004, The anatomical record. Part A, Discoveries in molecular, cellular, and evolutionary biology.

[31]  K. Sexton,et al.  Indoor air pollution: a public health perspective. , 1983, Science.

[32]  Jovan Pantelic,et al.  Personalized ventilation as a control measure for airborne transmissible disease spread , 2009, Journal of The Royal Society Interface.

[33]  A. Melikov,et al.  Measurement and prediction of indoor air quality using a breathing thermal manikin. , 2007, Indoor air.

[34]  P V Nielsen,et al.  Dispersal of exhaled air and personal exposure in displacement ventilated rooms. , 2002, Indoor air.

[35]  D. Rim,et al.  Occupational Exposure to Hazardous Airborne Pollutants: Effects of Air Mixing and Source Location , 2010, Journal of occupational and environmental hygiene.