Artifact in the bispectral index in a patient with severe ischemic brain injury.

UNLABELLED The electroencephalogram (EEG) has been used to predict neurological outcome in patients with anoxic-ischemic brain injury. The bispectral index (BIS) may be a useful alternative. A persistently low BIS associated with burst-suppression of the raw EEG in the setting of minimal hypnotic drug administration may indicate severe cerebral ischemia. We report a case where a patient with presumed ischemic brain injury and an extremely low BIS had an unexplained increase in BIS that could be attributed to electrocardiogram artifact. Care should be taken when interpreting BIS in the setting of anoxic-ischemic brain injury or brain death. IMPLICATIONS The bispectral index (BIS) can be prone to artifact. In this report we found that electrocardiogram artifact led to an apparent normal BIS in a patient with complete burst-suppression associated with severe brain injury.

[1]  F. Sterz,et al.  Early prediction of individual outcome after cardiopulmonary resuscitation , 1993, The Lancet.

[2]  Thomas M Hemmerling,et al.  Falsely increased bispectral index values in a series of patients undergoing cardiac surgery using forced-air-warming therapy of the head. , 2002, Anesthesia and analgesia.

[3]  V. Billard Souffrance cérébrale sous anesthésie générale: que peut-on attendre de la surveillance de l’EEG? , 2001 .

[4]  F. Angeleri,et al.  Eliciting P300 in comatose patients , 1995, The Lancet.

[5]  Peter S. Sebel,et al.  Bispectral Index Monitoring Allows Faster Emergence and Improved Recovery from Propofol, Alfentanil, and Nitrous Oxide Anesthesia , 1997 .

[6]  M. Kluger The Bispectral Index during an Anaphylactic Circulatory Arrest , 2001, Anaesthesia and intensive care.

[7]  M. Fischler,et al.  Value of bispectral index monitoring during cardiopulmonary resuscitation. , 2002, British journal of anaesthesia.

[8]  G. Mychaskiw,et al.  Falsely elevated bispectral index during deep hypothermic circulatory arrest. , 2000, British journal of anaesthesia.

[9]  G. Mychaskiw,et al.  Explicit intraoperative recall at a Bispectral Index of 47. , 2001, Anesthesia and analgesia.

[10]  Jin Liu,et al.  Electroencephalographic Bispectral Index Correlates with Intraoperative Recall and Depth of Propofol-Induced Sedation , 1997, Anesthesia and analgesia.

[11]  C. Stoutenbeek,et al.  Systematic review of early prediction of poor outcome in anoxicischaemic coma , 1998, The Lancet.

[12]  B. Guignard,et al.  Bispectral index increases and decreases are not always signs of inadequate anesthesia. , 2000, Anesthesiology.

[13]  H L Paz,et al.  Use of bispectral electroencephalogram monitoring to assess neurologic status in unsedated, critically ill patients , 2001, Critical care medicine.

[14]  S. R. Butler,et al.  Electrophysiological indicator of awakening from coma , 1993, The Lancet.

[15]  G N Kenny,et al.  Analysis of the EEG bispectrum, auditory evoked potentials and the EEG power spectrum during repeated transitions from consciousness to unconsciousness. , 1998, British journal of anaesthesia.

[16]  P. Coriat,et al.  Detection of brain death onset using the bispectral index in severely comatose patients , 2002, Intensive Care Medicine.

[17]  V. Billard Brain injury under general anesthesia: is monitoring of the EEG helpful? , 2001, Canadian journal of anaesthesia = Journal canadien d'anesthesie.

[18]  C. Yingling,et al.  P300 as a predictor of recovery from coma , 1990, The Lancet.

[19]  J. Gallagher,et al.  Pacer-induced artifact in the bispectral index during cardiac surgery. , 1999, Anesthesiology.

[20]  D. Choudhry,et al.  Bispectral Index Monitoring: A Comparison Between Normal Children and Children with Quadriplegic Cerebral Palsy , 2002, Anesthesia and analgesia.